M800VS/M80V Series Connection and Setup Manual
17 Setting the Hardware

17.6 Connecting and Setting the Remote I/O Unit

17.6 Connecting and Setting the Remote I/O Unit

17.6.1 Outline of the Remote I/O Unit

The specification varies for each remote I/O unit.
Each unit has one or two rotary switch(es) that determines the unit No. and associates the unit with its device No. (with X/Y).
FCU8-DX220
FCU8-DX230/DX231
(1)
(1)
(3)
(s1)
(s2)
(13)
(14)
(2)
(2)
(15)
(4)
(17)
FCU8-DX408
(s1)
(s2)
(13)
(14)
(20)
(17)
(15)
No. Connector name
(1) CJ31
Machine signal input
(2) CJ32
Machine signal output
(3) CJ33
Machine signal input
(4) CJ34
Machine signal output
(5) CJ35
Machine signal input
(6) CJ36
Machine signal output
(7) SDI
Safety machine signal input
(8) SDO
Safety machine signal output
(9) SDI1
Safety DI input
(10) SDI2
Safety DI input
(11) SDO1
Safety relay output
No.
Switch name
(s1)
Station No. group setting switch
(s2)
STATION No.
Station No. setting switch
(s3)
Station No. setting switch
FCU8-DX202
(s1)
(s2)
(13)
(14)
(15)
(17)
FCU8-DX409
(s1)
(s2)
(13)
(14)
(21)
(15)
(17)
Function
Function
FCU8-DX213/DX213-1 FCU8-DX654/DX654-1
(s1)
(s2)
(5)
(13)
(14)
(19)
(6)
(15)
(17)
FCU8-DX651
(1)
(13)
(s3)
(14)
(2)
(9)
(11)
(10)
(12)
(16)
No. Connector name
(12) SDO2
Safety relay output
(13) RIO1
Remote I/O 2.0 communication
(14) RIO2
Remote I/O 2.0 communication
(15) DCIN
24 VDC input
(16) DCOUT
24 VDC output
(17) FG
FG terminal
(18) FG
FG terminal (M4 screw)
Analog input
(19) AIO1
Analog output
(20) THERMISTOR
Thermistor input
(21) AI
Multi-analog input
387
(7)
(s1)
(s1)
(s2)
(s2)
(13)
(13)
(8)
(14)
(14)
(15)
(15)
(17)
(17)
(15)
(18)
Function
IB-1501613-A

Advertisement