30 Synchronous Control and Multiple-axis Synchronization Control
30.1 Synchronous Control

30.1.1.1 Synchronous control mode

The following two operation methods are available in the synchronous control mode.
 Synchronous operation
This is a method that both master and slave axes are moved simultaneously with the movement command for the master
axis.
 Independent operation
This is a method that either the master or slave axis is moved with the movement command for the master axis.

30.1.1.2 Correction mode

The synchronization is temporary canceled to adjust the balance of the master and slave axes during the synchronous control
mode in the machine adjustment. Each axis can be moved separately with the manual handle feed or the arbitrary feed in
manual mode. If the operation mode other than the manual handle feed and arbitrary feed in manual mode is applied during
the correction mode, the operation error will occur.