Mitsubishi Electric M800VS Series Connection And Set Up Manual page 597

Hide thumbs Also See for M800VS Series:
Table of Contents

Advertisement

M800VS/M80V Series Connection and Setup Manual
33 Device Open Parameter Screen
Display item
(5) Display format
(6) Group comment
IB-1501613-A
Designate the display format of the data, the restriction of display, and the
state of input protection.
7
6
5
4
3
2
1
<(a) Cancel input protection>
1: Not check
Input protection check for the data protection key 2 will not be executed
in the group detail screen.
0: Check
Input protection check for the data protection key 2 will be executed in
the group detail screen.
The name of the data protection key varies depending on the machine tool
builder.
Refer to the instruction manual issued by the machine tool builder for de-
tails.
<(b) Cancel display restrictions>
1: Display
The group detail screen is displayed without entering the machine tool
builder's password.
0: Not display
The group detail screen is not displayed when the password is not en-
tered.
<(c) BCD format>
1: Enable
Display the group detail screen data in BCD format.
0: Disable
<(d) BIT format>
1: Enable
Display the group detail screen data in BIT format.
0: Disable
<(e) HEX format (Hexadecimal format)>
1: Enable
Display the group detail screen data in HEX format.
0: Disable
<(f) Sign (Decimal format only)>
1: Unsigned
Displays the group detail screen data in unsigned decimal format.
0: Signed
Display the group detail screen data in decimal format with sign.
When "BCD format", "HEX format" and "BIT format" are all set to "0" (OFF)
or more than one bit is set to "1" (ON), the data display format will be dec-
imal format with sign.
Display a comment that is defined in the comment definition file for the de-
vice open or a comment of a head device of the group.
 When defining a group
Displays a comment for each group.
It will be displayed regardless of device allocation and the setting of num-
ber of data.
 When not defining a group
Displays a comment for the device set under "(2) device allocation".
Details
0
(a)
(b)
(c)
(d)
(e)
(f)
566
Setting range
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80v series

Table of Contents