M800VS/M80V Series Connection and Setup Manual
4 General Specifications
4.9 Remote I/O Unit
LED: FCU8-DX651
(2)
(1)
No.
Name
H1
Safety relay output SYR00 status
(1)
H2
Safety relay output SYR01 status
H3
Safety relay output SYR02 status
H4
Safety relay output SYR03 status
ALM
RIO communication error
(2)
DCIN
Energization status of 24 VDC input of DCIN connector Green Lit
(3)
FUSE
Fuse status
(4)
IB-1501613-A
(3)
(4)
Function
Status
Color
Normal
At fault
Green Lit
Not lit
Green Lit
Not lit
Green Lit
Not lit
Green Lit
Not lit
Red
Not lit
Lit
Not lit
Green Lit
Not lit
138
Details
Not lit when the relay is welded.
Not lit when the relay is welded.
Not lit when the relay is welded.
Not lit when the relay is welded.
Lit when RIO communication er-
ror has occurred.
Lit when a current is applied.
Not lit when a fuse has been
blown out.