Mitsubishi Electric M800VS Series Connection And Set Up Manual page 67

Hide thumbs Also See for M800VS Series:
Table of Contents

Advertisement

M800VS/M80V Series Connection and Setup Manual
4 General Specifications
4.3 Control Unit [M800VS]
[Connecting a pulse-controlled inverter [M80V]]
For M80V, RIO1 and RIO2 connectors can be used as interfaces to output pulses. With this function, you can connect a
pulse-controlled inverter with RS422 interface to M80V.
Note
 When you use a function with pulse output, remote I/O unit cannot be connected to the RIO1 and RIO2 connectors.
RIO1
A
1
O A/PULSE/CW
1
2
NC
2
3
FG
3
<Pulse output specifications>
Number of control axes
Pulse output mode (*1)
Pulse output frequency
Pulse output signal
Differential output voltage
Signal voltage
Common mode output voltage
Output current
Cable length
(*1) The output signal logic type can be selected with the logic selecting function.
Pulse output mode
A
A*
A phase/B phase
B
B*
PULSE
PULSE*
PULSE/SIGN
SIGN
SIGN*
CW
CW*
CW/CCW
CCW
CCW*
IB-1501613-A
B
O A*/PULSE*/CW*
1
O B/SIGN/CCW
0 V
2
NC
3
One axis
A phase/B phase, PULSE/SIGN, CW/CCW
1 to 4,000,000 pulses per second
RS422 differential driver output
2.0 V or greater
3.0 V or less
250 mA in maximum
30 meters or less
Positive logic
Forward rotation
Reverse rotation
Forward rotation
Reverse rotation
Forward rotation
Reverse rotation
RIO2
A
B
1
O B*/SIGN*/CCW*
NC
2
0 V
FG
3
NC
Negative logic
Forward rotation
Reverse rotation
A
A*
B
B*
Forward rotation
Reverse rotation
PULSE
PULSE*
SIGN
SIGN*
Forward rotation
Reverse rotation
CW
CW*
CCW
CCW*
36

Advertisement

Table of Contents
loading

This manual is also suitable for:

M80v series

Table of Contents