20 Sequence Program Writing

20.1 Writing Sequence Program using the SD Card

Sequence program writing is executed by connecting a personal computer, in which GX Developer or GX Works2 has been
installed, to the control unit.
For details of GX Works2,.refer to the "PLC Development Manual"
For details of GX Developer, refer to instruction manuals and specifications manuals related to GX Developer which are listed
in "Manual List".
20.1 Writing Sequence Program using the SD Card
Save the sequence program in an SD card and write the data to NC using the external file operations on PLC onboard.

20.2 Setting the Ethernet Communication

20.2.1 Confirming the IP Address for CNC

Confirm the IP address set for the CNC. IP address is set to the following parameter.
Basic common parameter
#1926
#1927
The case of when the initial value "192.168.200.1" after SRAM clear has been set is explained as an example in this chapter.

20.2.2 Setting the IP Address for PC Side

For the personal computer for which GX Developer or GX Works2 is available, IP address has to be set within the same
subnet mask as CNC unit.
(1) Select [Start] - [Control Panel] - [Network and Internet] - [Network and Sharing Center] from task bar.
(2) "Network and Sharing Center" is displayed. Click [Local Area Connection].
IB-1501613-A
Item
Global IP address
IP address for CNC seen from an external source
Global Subnet mask
Subnet mask of #1926
Description
422
Setting example
192.168.200.1
255.255.255.0