Example Of Wiring Cj42 (Fcu8-Dx760) - Mitsubishi Electric M800VS Series Connection And Set Up Manual

Hide thumbs Also See for M800VS Series:
Table of Contents

Advertisement

M800VS/M80V Series Connection and Setup Manual
9 Connection of Operation Panel I/O Unit
9.8 Connecting with Machine Operation Panel

9.8.4 Example of Wiring CJ42 (FCU8-DX760)

Machine side
Stabilized
power supply
24VDC(+)
0V
FG
For connection details, refer to the descriptions on machine output connector pin assignment in " (11) CJ42 (Machine signal
output)" of "4.8 Operation Panel I/O Unit".
IB-1501613-A
FCU8-DX760
CJ42
B20
Y260
B19
Y261
B18
Y262
B17
Y263
B16
Y264
B15
Y265
B14
Y266
B13
Y267
B12
Y268
B11
Y269
B10
Y26A
B09
Y26B
B08
Y26C
B07
Y26D
B06
Y26E
B05
Y26F
B04
DOCOM
B03
DOCOM
B02
DOCOM
B01
DOCOM
A20
Y270
A19
Y271
A18
Y272
A17
Y273
A16
Y274
A15
Y275
A14
Y276
A13
Y277
A12
Y278
A11
Y279
A10
Y27A
A09
Y27B
A08
Y27C
A07
Y27D
A06
Y27E
A05
Y27F
A04
DOCOM
DOCOM
A03
0V
A02
A01
0V