35 Data Backup and Restoration
35.2 All Restoration
Move the cursor to select the file.
(5)
Press the [INPUT] key.
The cursor moves as follows:
[ ↓ ] key:
Auto1 -> Auto2 -> Auto3 -> Manual -> Auto1 ...
[ ↑ ] key:
Auto1 -> Manual -> Auto3 -> Auto2 -> Auto1-> ...
Press [Y], [y] or [INPUT].
(6)
The restoration is completed without error.
(7)
Note
(1) When the restoration fails, perform the restoration again otherwise it may cause an abnormal operation.
(2) Restored data writes over the previous absolute position data. Carry out the absolute position detection again after resto-
ration.
IB-1501613-A
The operation message "OK? (Y/N)" will display.
<Note>
 If there are no files at the current cursor position, the op-
eration message "Select directory to restore" will display.
Select the file again and then press the [INPUT] key.
The restoration starts.
"Executing" and "*" are displayed for the state of file under
processing.
<Note>
 If a PLC is in operation, the message "PLC running.
Stop? (Y/N)" will display. Press [Y], [y] or [INPUT] to
continue the restoration.
 When tool data is being sorted, the operation message
"File access error" will display and prevent the resto-
ration from executing.
 For the custom data, the restoration cannot be canceled
during its execution.
The state for files that have been restored will update to
"Complete", and the operation message "Restoration com-
plete" will display.
"Not executed" will be displayed for file which could not be
restored, for instance, due to no file being present.