M800VS/M80V Series Connection and Setup Manual
4 General Specifications
4.9 Remote I/O Unit
(21) AI (Multi-analog input)
1
13
13
FG
1
14
NC
2
15
V+/A
3
CH3
16
l+/a/CJ+
4
17
V-/l-/B
5
18
b/CJ-
6
19
V+/A
7
20
l+/a/CJ+
8
21
V-/l-/B
9
CH4
22
b/CJ-
10
23
NC
11
24
FG
12
<Cable side connector type>
Connector: DFMC1,5/12-ST-3,5-LR
Manufacturer: Phoenix Contact
(The cable side connector is attached to the unit.)
[Outline of multi-analog input circuit]
There are four types of multi-analog input as below:
Voltage input
Current input
Thermocouple input
Resistance temperature detector input
The measurement mode (voltage measurement, current measurement, temperature (thermocouple) measurement and
temperature (resistance temperature detector) measurement) can be set for each CH and input corresponding to the mode
can be performed.
All CHs (CH1 to CH4) are set to the voltage measurement mode when the machine is delivered.
Note
Input the signal within the appropriate input range for the set measurement mode.
- Do not input the voltage when the current or temperature (thermocouple or resistance temperature detector) measure-
ment mode is set. This could result in faults of the unit. Pay close attention to the combination of the measurement
mode setting and input.
Running-in is required for about 10 to 15 minutes after the power is ON until the measurement value is stable.
Do not apply voltage or current from external devices before turning ON the power of multi-analog input unit. This may
damage the multi-analog input unit.
Turn ON the power of the multi-analog input unit and external device at the same time, or wire circuit so that the power sup-
ply of the multi-analog input unit is turned ON first.
12
24
FG
NC
V+/A
CH1
l+/a/CJ+
V-/l-/B
b/CJ-
V+/A
l+/a/CJ+
V-/l-/B
CH2
b/CJ-
NC
FG
131
IB-1501613-A