M800VS/M80V Series Connection and Setup Manual
4 General Specifications
4.1 Environment Conditions [M800VS]

4.1.2 24 VDC Stabilized Power Supply Selecting Conditions

Consider the following characteristics for the stabilized power supply, and select the power supply that complies with laws,
regulations, or safety standards of the country where the machine will be installed.
Item
Voltage
Voltage fluctuation
Current
Output
Ripple noise
Output holding
time
Overcurrent output
shutoff function
CAUTION
Using a stabilized power supply without overcurrent protection may cause the unit's failure due to miswiring of 24 V.
Specifications
When the stabilized power supply and 24 VDC input unit are distant, select the stabilized
24 VDC
power supply which is possible to set output voltage 24 VDC or more allowing for the influ-
ence of voltage down by the cable.
±5%
Calculate the current value as a reference of maximum current consumption for the unit
-
which uses the power supply.
0.2 V (P-P)
Output holding time is decided by loading ratio; however, the stabilized power supply which
min 20 ms
complies with the specification on the left must be selected during maximum loading.
Use a power supply having the overcurrent output shutoff function.
-
Remarks
25
IB-1501613-A