Connecting With Thermistor (Fcu8-Dx408) - Mitsubishi Electric M800VS Series Connection And Set Up Manual

Hide thumbs Also See for M800VS Series:
Table of Contents

Advertisement

M800VS/M80V Series Connection and Setup Manual
10 Connection of Remote I/O Unit

10.10 Connecting with Thermistor (FCU8-DX408)

10.10 Connecting with Thermistor (FCU8-DX408)
Connect the thermistor with THERMISTOR connector.
The maximum cable length is 25 m.
The recommended shield cable is "HK-SB/20276XL, black, LF 1P X 22AWG" made by Taiyo Cabletec.
Thermistor
Cable with shield
Maximum: 25m
[Related items]
Connector pin assignment: "4.9 Remote I/O Unit" (THERMISTOR connector)
CAUTION
(1) Connect the cable to the designated connector. Incorrect connections could damage the device.
(2) Do not connect or disconnect the cables between units while the power is ON.
(3) Use shielded cable and ground it in order to reduce noise interference.
THERMISTOR
301
IB-1501613-A