7 Connection of Control Unit
7.3 Connecting with Emergency Stop Signal
Drive unit (MDS-EJ/EJH) external emergency stop: Example
Control unit
Control unit
+24V
EMGIN
FG
LG
Emergency stop input circuit
Note
(1) External emergency stop cannot substitute the emergency stop signal which is input to NC.
It is a function which helps the NC emergency stop.
(2) When duplicating emergency stop input, wire the NC emergency stop input and the power supply unit external emer-
gency stop input from the same emergency stop switch.
IB-1501613-A
J120
EMG
3
3
2
2
1
1
Stabilized power supply
Emergency
stop switch
CN9
MDS-EJ/EJH
222
+24V
0V(LG
MDS-EJ/EJH
R
5
20