M800VS/M80V Series Connection and Setup Manual
7 Connection of Control Unit

7.9 Connecting with Skip Signal (Sensor)

7.9 Connecting with Skip Signal (Sensor)
Connect the skip signals to SKIP connector of the control unit.
Skip signals are used for processing high-speed signals. Always shield the cable.
Control unit
SKIP
Note
(1) Connecting the skip signal cable to a wrong connector causes a damage on the control unit when turning ON the skip sig-
nal power supply. Confirm the wiring before turning the power ON.
Connection of skip signal cable
 0 V connections at COM terminal
Control unit
SKIP
2.35kΩ
2
SI1
12
SI2
3
SI3
13
SI4
7
SI5
17
SI6
8
SI7
18
SI8
COM
1,5,11,15
0V connection at COM terminal
IB-1501613-A
COM
COM
SK0
J100
SK1
SK2
SK3
COM
COM
SK4
SK5
SK6
SK7
J100
FG
236
Stabilized
power supply
24VDC(+)
0V
FG