4 General Specifications
4.11 Function Expansion Unit
LED
(1)
(2)
No.
Name
MS (Green/red)
(1)
(Module status)
NS (Green/red)
(2)
(Communication status)
Note
 Ignore all LED combinations not listed in the table above.
(1)
(2)
Green LED
Red LED
Flashing
Flashing
Flashing
Not lit
Lit
Not lit
Not lit
Flashing
Not lit
Lit
Flashing green/red (alternating)
Not lit
Not lit
Flashing
Not lit
Lit
Not lit
Not lit
Flashing
Not lit
Lit
151
Description
Device self-testing
Waiting for initialization
Normal operation
Recoverable error
Unrecoverable error (hardware replacement required)
Self-diagnosis
No IP address
Not connected
Normal operation
Connection timeout
Duplicate IP address