23 Setting the Tool Entry Prohibited Range
23.2 Stored Stroke Limit

23.2.2 Stored Stroke Limit I

A stroke limit function used by the machine tool builder. Boundaries are set by the parameters ("#2013 OT - (Soft limit I -)" and
"#2014 OT + (Soft limit I +)"). The outside of the set boundary is the prohibited range.
When used with the stored stroke limit II function, the confined range designated by the two functions becomes the moveable
range.
2
: Moveable range
: Prohibited range
(A): Set value for (-) side
(B): Set value for (+) side
Positions No. 1 "#2014 OT+ (Soft limit I +)" and No. 2 "#2013 OT- (Soft limit I -)" are set using coordinates from the basic
machine coordinate system.
Note
(1) This function will be invalid if the same non-zero value is set for both "#2013 OT -" and "#2014 OT +".