4 General Specifications

4.1 Environment Conditions [M800VS]

4.1 Environment Conditions [M800VS]

4.1.1 Installation Environment Conditions

Unit name
Item
Type
During op-
Ambient
eration
tempera-
During
ture
storage
Long term 10% to 75% RH (with no dew condensation)
Ambient
humidity
Short term 10% to 95% RH (with no dew condensation) (*1)
Vibration resistance
Shock resistance
Working atmosphere No corrosive gases, dust or oil mist
Altitude
General
specifica-
Power supply voltage
tions
Current consumption 24 V, 2.5 A
Maximum
heating val-
(W)
ue
Mass
(kg)
Outline di-
mensions
(mm)
W × H
or
W × H × D
(*1) "Short term" means roughly within one month.
(*2) The current consumption of the display unit is included in that of the control unit.
Note
(1) For the whole NC system, consider the characteristics of the drive units when the altitude is more than 1000 meters
above sea level.
Refer to the manual of drive unit for details.
(2) When the display unit is mounted on an incline, the inclination angle to place the unit should be 30 degrees or less from
the vertical direction.
IB-1501613-A
Control unit
FCU8-MU551/MA551
0 °C to 58 °C
-20 °C to 60 °C
2
4.9 m/s
or less
2
29.4 m/s
or less
Operation/Storage: 1000 meters or less above sea level, Transportation: 13000 meters or less
above sea level
24 VDC
16
1.1
239.1 × 173.4 × 75
22
Display unit
FCU8-DU142-31: (10.4-type)
FCU8-DU182-31: (15-type)
FCU8-DU142-31: 12 VDC/5 VDC/3.3 VDC
FCU8-DU182-31: 12 VDC/5 VDC/3.3 VDC
(Supply from control unit)
- (*2)
FCU8-DU142-31: 10
FCU8-DU182-31: 14
FCU8-DU142-31: 1.7
FCU8-DU182-31: 3.9
FCU8-DU142-31: 290 × 220
FCU8-DU182-31: 400 × 320