5
Servicing
Inspection and maintenance every 6000 operating hours or every 4 years
Inspection and maintenance every 6000 operating hours or ev-
ery 4 years
Replace hydraulic oil
WARNING
Adding hydraulic oil with the wrong viscosity may
result in brake malfunctions . This may also present
a risk of accidents to the driver.
Only hydraulic oil with suitable viscosity should be
used. See Recommendations for working materi-
als
ENVIRONMENT NOTE
Take note of information about working ma-
terials. See Recommendations for working
materials
NOTE
Hydraulic oil can only be extracted with a hand
pump.
Fully lower fork carriage.
Press emergency cut-off knob and remove
key switch from switch latch.
Remove rubber mat from floor plate.
Remove floor plate.
Remove filter cover (1) by turning anti-clock-
wise.
Slowly pull out filter cartridge (2) so oil can
run back into hydraulic tank.
Remove filter cartridge entirely.
Unscrew breather (3).
Extract hydraulic oil with a suitable hand
pump.
Add new hydraulic oil to hydraulic oil tank.
NOTE
The fill quantity depends on the individual type
and height of the lift mast:
An oil fill quantity of approx. 8.9 litres cor-
responds to the oil level marking (1) on the
132
1
1
Operating Instructions – 386 807 1001 EN – 03/2006
2
e3861377
Need help?