5
Servicing
Inspection and maintenance every 3000 operating hours or every 2 years
Check operating and steering hy-
draulics for leakage
Remove rubber mat from floor plate.
Unscrew 2 screws (1) on side of driver's
seat.
Lift up floor plate (2) and attach with loop (4)
to adjusting knob (5).
NOTE
Should it be necessary to completely disman-
tle the floor plate (2) , all 4 fastening screws
must be unscrewed and the connector plug (3)
detached from the drive control pedal system.
Check hydraulic pump of operating and
steering hydraulics, valves and lines for
leakage.
Replace porous hoses.
Check lines for scuffing and replace if nec-
essary.