Inspection and maintenance every 3000 operating hours or every 2 years
Check the condition and secure po-
sitioning of electric cables, cable
connectors and connections
NOTE
Oxidised connections and brittle cables result
in voltage drops , so causing malfunctions.
Remove the screws from the floor plate
fastening (pedals) and lift up floor plate.
Check all electric cables and connections
on contactor support.
Cable connections on electric motors:
check plug connections for secure posi-
tioning and oxidation residues.
Check battery cables for secure positioning.
Check electric wiring for abrasion and se-
cure positioning.
Check earth wire for secure positioning.
Remove oxidised connections and replace
brittle cables.
Operating Instructions – 386 807 1001 EN – 03/2006