Introduction - Olympus MX63 Instructions Manual

Semiconductor/fpd/industrial inspection microscopes
Table of Contents

Advertisement

Introduction

This microscope employs the UIS2 optical systems. If you use an eyepiece, objective or condenser, etc. together with
this microscope, be sure to use those of UIS2 optical system series.
Using inappropriate units restricts the performance.
(There are other units usable with the UIS series. Contact Olympus or refer to the latest catalogs.)
This instruction manual applies to users of this product and Olympus distributors. However, some part at the end of this
instruction manual applies to Olympus distributors only.
Configuration of instruction manuals
Read all instruction manuals provided with the units you purchased.
The following instruction manuals are prepared for the units to be used with this product.
Manual names
Semiconductor / FPD / Industrial
Inspection Microscopes
(this instruction manual)
U-RFL-T power supply for mercury burner /
U-RX-T power supply for xenon burner
TH4 power supply for halogen bulb
Light guide illumination system
Label of immersion oil
Read the label of the immersion oil you purchased.
Immersion oil
IMMOIL-F30CC
SEMI
This device has been subjected to the compliance evaluations of the following guidelines under the
SEMI Standard.
· S2-0715: Safety Guidelines for Semiconductor Manufacturing Equipment
· S8-0915: Safety Guidelines for Ergonomics Engineering of Semiconductor Manufacturing Equipment
Intended use
This product is designed to observe magnified images of samples for industrial applications.
Appropriate samples include semiconductors, electrical components, molded parts or mechanical parts.
Industrial applications include observation, inspection or measurements.
Do not use this product for any purpose other than its intended use.
Reflected brightfield observation, reflected darkfield observation,
reflected differential interference contrast observation, reflected
simple polarization observation, reflected fluorescence observation,
reflected infrared observation, reflected brightfield/darkfield
simultaneous observation, transmitted brightfield observation and
transmitted simple polarization observation
Connection of the mercury lamp housing with the power supply
Connection of the halogen lamp housing with the power supply
Connection of the light guide illumination system with the liquid light
guide, etc.
Cautions and handling procedures of the immersion oil
MX63/MX63L
Main contents
Main contents
1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx63l

Table of Contents