Connector Pinouts; Asi Connector Pinout; Asi Interface Defaults - Comtech EF Data CDM-710 Installation And Operation Manual

Broadcast satellite modem

Advertisement

CDM-710 Broadcast Satellite Modem
CDI-40 ASI Data Interface
0x47
Sync
Byte

10.4 Connector Pinouts

10.4.1

ASI Connector Pinout

The ASI interface is as follows:
Connector
J2, J3
J4, J5
Connector
J2,
J3
J4, J5

10.5 ASI Interface Defaults

Default settings for the interface are listed in the following table:
0x1F, 0xFF, 0x1F
Bytes 2-5
PL/10881-3
Description
Rx Data, BNC Female
Tx Data, BNC female
PL/10881-4
Description
Rx Data, BNC Female
Rx Data, BNC Female, 1:1 Redundant (High-Level)
Tx Data, BNC female
Interface Defaults
Mode
Active Tx Input
Data or Clock
ASI Frame Format
Loss of Data
Loop Bandwidth
1, ASI active
J4
Normal
188
Alarm
Wide
10–6
Revision 9
MN/CDM710.IOM
0xFF
Not Specified
Signal Direction
Output
Input
Signal Direction
Output
Output
Input