Download Print this page

Comtech EF Data CDM-710 Installation And Operation Manual page 207

Broadcast satellite modem

Advertisement

CDM-710 Satellite Modulator
Remote Control
Command
Parameter
(Instruction
for Command
Type
Code and
Qualifier)
Retrieve next 5
N/A
75 bytes
unread Stored
Events
Serial Number
N/A
9 bytes
Software
N/A
5 bytes
Revision
Arguments
Description of Arguments
or Response
to Query
Unit returns the oldest 5 Stored Events which have not yet been
read over the remote control. Reply format: {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-
body, where Sub-body= ABCddmmyyhhmmss,
A being the fault/clear indicator.
F=Fault
C=Clear
I=Info
B being the fault type where:
1=Unit
2=Rx Traffic
3=Tx Traffic
4=Log
C is Fault Code numbers, as in FLT? or Info Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.
If there are no new events, the response is RNE*.
Used to query the unit 9-digit serial number. Unit returns its S/N
in the form xxxxxxxxx.
Example: SNO=176500143
Unit returns the value of the internal software revision installed
in the unit, in the form: Boot:X.X.X Bulk1:Y.Y.Y Bulk2: Z.Z.Z
Example: SWR=Boot:1.0.3 Bulk1:1.0.1 Bulk2:1.0.0
Response
to
Command
N/A
N/A
N/A
A–46
Revision 9
MN/CDM710.IOM
Query
(Instruction
Response to Query
Code and
Qualifier)
RNE?
RNE={CR}ABCddmmy
yhhmmss{CR}ABCddm
myyhhmmss{CR}ABCd
dmmyyhhmmss{CR}AB
Cddmmyyhhmmss
{CR}ABCddmmyyhhm
mss
SNO?
SNO=xxxxxxxxx
SWR?
SWR=Boot:X.X.X
Bulk1:Y.Y.Y
Bulk2:Z.Z.Z

Advertisement