Download Print this page

Comtech EF Data CDM-710 Installation And Operation Manual page 208

Broadcast satellite modem

Advertisement

CDM-710 Satellite Modulator
Remote Control
Command
Parameter
(Instruction
for Command
Type
Code and
Qualifier)
Real-time
TIM=
6 bytes
Clock Time
Temperature
N/A
3 bytes
Arguments
Description of Arguments
or Response
to Query
A time in the form hhmmss, indicating the time from midnight,
where:
hh = hours (00 to 23)
mm = minutes (00 to 59)
ss = seconds (00 to 59)
Example: TIM=231259 (23 hours:12 minutes:59 seconds)
Unit returns the value of the internal temperature, in the form of
sxxx (degrees C). Where s is the sign and and xxx is the number
of degrees.
Example: TMP=+026
Response
to
Command
TIM=
TIM?
TIM*
TIM#
N/A
A–47
Revision 9
MN/CDM710.IOM
Query
(Instruction
Response to Query
Code and
Qualifier)
TIM?
TIM=hhmmss
TMP?
TMP=sxxx