2.2.4.9 LED status indicators

LED status indicators are located on the bottom of the PPC2100 between the ETH2 interface and the power button.
The following intervals are used for the LED status indicators:
Block size: 250 ms
Repeat interval: 500 ms, 2 boxes thus represent one interval
LED
Color
Status
Power
Green
On
Red
On
Red/Green Blinking
CFast
Yellow
On
Link
Yellow
On
Blinking
Run
Green
Blinking
Green
On
Red
On
Orange
Blinking
Panel PC 2100 user's manual V1.17
LED "Power"
LED "CFast"
LED "Link"
LED "Run"
Explanation
Power supply OK
The system is in standby mode (S5: soft-off mode or S4: hiber-
nation/suspend-to-disk mode).
Faulty or incomplete BIOS, MTCX or I/O FPGA update, power
supply OK
Faulty or incomplete BIOS, MTCX or I/O FPGA update, stand-
by mode (S5: soft-off mode or S4: hibernation/suspend-to-disk
mode)
Indicates CFast access.
Indicates an active SDL connection on the male panel connec-
tor.
An active SDL connection was interrupted by a loss of power
to the panel.
Information:
Check the power supply / power connector of the
connected panel.
Automation Runtime is starting up.
This is controlled by Automation Runtime (ARemb and ARwin).
Application running
This is controlled by Automation Runtime (ARemb and ARwin).
Application in service mode
This is controlled by Automation Runtime (ARemb and ARwin).
A license violation exists.
This is controlled by Automation Runtime (ARemb and ARwin).
Table 45: LED status indicators - Data
Technical data
LED status indicators
55