B&R Panel PC 2100 User Manual page 179

Hide thumbs Also See for Panel PC 2100:
Table of Contents

Advertisement

Model number
Electrical characteristics
Power consumption
Operating conditions
Pollution degree per EN 61131-2
Environmental conditions
Temperature
Operation
Storage
Transport
Relative humidity
Operation
Storage
Transport
Mechanical characteristics
Weight
1)
Yes, although applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)
Yes, although applies only if all components installed in the complete system have this certification and are listed on the associated DNV GL certificate for
the product family.
3)
For more information, see Automation Help (Communication - POWERLINK - General information - Hardware - IF / LS).
2.3.5.4.3.1 POWERLINK interface - Pinout
The POWERLINK interface on the system unit is referred to as IF1.
Wiring
Cable length
Status LED
Green
Link LED
Yellow
Link (POWERLINK net-
work connection available)
1)
The interfaces, etc. available on the device or module have been numbered as such for the purpose of clear differentiation. This numbering may deviate
from the numbering used by the respective operating system, however.
2)
This interface is referred to as IF1 in Automation Studio / Automation Runtime.
2.3.5.4.3.2 COMA serial interface - Pinout
Serial interface COMA is referred to as IFx on the system unit.
Type
UART
Transfer rate
Bus length
Pin
1
2
3
4
5
6
7
8
9
10
1)
The interfaces, etc. available on the device or module have been numbered as such for the purpose of clear differentiation. This numbering may deviate
from the numbering used by the respective operating system, however.
2)
This interface (if available) is enabled automatically in BIOS as COMA with default I/O address 3F8h and IRQ 4.
3)
This interface is referred to as IF5 in Automation Studio / Automation Runtime.
Panel PC 2100 user's manual V1.17
Table 156: 5ACCIF01.FPLS-000 - Technical data
S/STP (Cat 5e)
Max. 100 m (min. Cat 5e)
On
See Status/Error LED.
On
Activity (blinks to indi-
cate active data transfer)
Table 157: 5ACCIF01.FPLS-000 - POWERLINK interface
Serial interfaceCOM A - IFx
RS232
RS232, modem supported, not electrically isolated
16550-compatible, 16-byte FIFO
Max. 115 kbit/s
Max. 15 m
Assignment
DCD
DSR
RXD
RTS
TXD
CTS
DTR
RI
GND
GND
Table 158: 5ACCIF01.FPLS-000 - Interface COMA
5ACCIF01.FPLS-000
Pollution degree 2
-20 to 55°C
-20 to 60°C
-20 to 60°C
5 to 90%, non-condensing
5 to 95%, non-condensing
5 to 95%, non-condensing
POWERLINK - IF1
1)2)
Off
Off
LED "Link"
1)2)3)
1.5 W
25 g
RJ45, female
1
10-pin, male
1
3
5
7
9
2
4
6
8 10
Technical data
LED "Status"
179

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mappc2100-eng

Table of Contents