2.3.5.1.3.4 X2X Link master interface - Pinout
The X2X Link master interface on the system unit is referred to as IFx.
The electrically isolated X2X Link master interface is a 10-pin connector.
Pin
1
2
3
4
5
6
7
8
9
10
1)
The interfaces, etc. available on the device or module have been numbered as such for the purpose of clear differentiation. This numbering may deviate
from the numbering used by the respective operating system, however.
2)
This interface can only be used in Automation Runtime and is referred to as IF2 in Automation Studio / Automation Runtime. It is not a "PC interface" and
therefore not shown in BIOS.
2.3.5.1.3.5 Shielding
For the interfaces on the 10-pin female connector, the interface shield can be put on pin 2 of the female connector.
A functional ground connection and screw, which can also be used for the cable shields, is located on the interface
plate of the system unit.
2.3.5.1.3.6 LED status indicators - L1, L2, L3
The interface option has 3 integrated LEDs located above the terminating resistor.
LED
Color
Status
L1
Yellow
On
Off
L2
Green
On
Blinking
L3
Green-Red
On
Off
LED "Status/Error"
LED "Status/Error" is a green and red dual LED. The LED states have a different meaning depending on the
operating mode.
Ethernet mode
In this mode, the interface is operated as an Ethernet interface.
Green - Status
On
Panel PC 2100 user's manual V1.17
X2X Link master - IFx
Assignment
X2X H
Shield
X2X L
X2X GND
-
-
-
-
-
-
Table 124: 5ACCIF01.FPCC-000 - X2X Link master interface
LED status indicators
Explanation
The CAN bus 1 terminating resistor is enabled.
The CAN bus 1 terminating resistor is disabled.
POWERLINK Link LED
Indicates a connection to a POWERLINK net-
work.
POWERLINK Link LED
Data transfer in progress.
POWERLINK Status/Error LED
See
"LED
"Status/Error"".
POWERLINK Status/Error LED
See
"LED
"Status/Error"".
Table 125: 5ACCIF01.FPCC-000 - LED status indicators
Description
The interface is being operated as an Ethernet interface.
Table 126: LED "Status/Error" - Ethernet mode
1)2)
10-pin, male
1
3
5
2
4
6
L1
L2
Technical data
7
9
8 10
L3
163