2.3.5.8.3.5 Terminating resistor
A terminating resistor is integrated for each COM on the interface option; they are located to the left and right of
the IFx connector. The terminating resistor is enabled or disabled using a switch. LED status indicators L2 and L3
indicate whether the terminating resistor is enabled or disabled.
On
The terminating resistor is switched on.
Off
The terminating resistor is switched off.
2.3.5.8.3.6 Shielding
The shields for the cables connected to the 10-pin female connector can be connected to the screw connection for
cable shields (see
"Device interfaces - Overview" on page
of the system unit's interface cover.
2.3.5.8.3.7 LED status indicators L2, L3
LEDs are integrated in the interface option; they are located above the terminating resistor.
LED
Color
Status
L2
Yellow
On
Off
L3
Yellow
On
Off
2.3.5.8.3.8 Firmware
In order to ensure the functionality of the interface option, the following firmware version (MTCX) or later must be
installed on the PC:
• Automation PC 2100: V1.10
• Panel PC 2100: V1.10
The firmware can be downloaded from the B&R website (www.br-automation.com).
For information about firmware upgrades, see section
273.
2.3.5.8.3.9 Hardware
The following minimum hardware revisions are required on the PC to ensure the functionality of the interface option:
• 5PPC2100.BY01-000: Rev. I0 or later
• 5PPC2100.BY11-000: Rev. H0 or later
• 5PPC2100.BY22-000: Rev. I0 or later
• 5PPC2100.BY34-000: Rev. I0 or later
• 5PPC2100.BY44-000: Rev. J0 or later
• 5PPC2100.BY48-000: Rev. D0 or later
Panel PC 2100 user's manual V1.17
Terminating resistor
Table 210: Terminating resistor
LED status indicators
Explanation
The COM D terminating resistor is enabled.
The COM D terminating resistor is disabled.
The COM A terminating resistor is enabled.
The COM A terminating resistor is disabled.
Table 211: 5ACCIF01.FSS0-000 - LED status indicators
48) as an alternative to the functional ground connection
"Upgrading the firmware on the Panel PC 2100" on page
Technical data
Terminating resistor
On
Off
L2
L3
205

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mappc2100-eng

Table of Contents