B&R Panel PC 800 User Manual
Hide thumbs Also See for Panel PC 800:
Table of Contents

Advertisement

Quick Links

Panel PC 800
User's Manual
Version: 1.30 (December 2014)
Model no.: MAPPC800-ENG
All information contained in this manual is current as of its creation/publication. B&R reserves the right to change
the contents of this manual without notice. The information contained herein is believed to be accurate as of
the date of publication; however, Bernecker + Rainer Industrie-Elektronik Ges.m.b.H. makes no warranty, ex-
pressed or implied, with regard to the products or documentation contained within this manual. In addition,
Bernecker + Rainer Industrie-Elektronik Ges.m.b.H. shall not be liable for any incidental or consequential damages
in connection with or arising from the furnishing, performance or use of the product(s) in this documentation. Soft-
ware names, hardware names and trademarks are registered by their respective companies.
1

Advertisement

Table of Contents
loading

Summary of Contents for B&R Panel PC 800

  • Page 1 Panel PC 800 User's Manual Version: 1.30 (December 2014) Model no.: MAPPC800-ENG All information contained in this manual is current as of its creation/publication. B&R reserves the right to change the contents of this manual without notice. The information contained herein is believed to be accurate as of the date of publication;...
  • Page 2 Chapter 1: General information Chapter 2: Technical data Chapter 3: Installation Chapter 4: Software Chapter 5: Standards and certifications Chapter 6: Accessories Chapter 7: Maintenance and service Appendix A...
  • Page 3: Table Of Contents

    2.6.6 ................................45 2.6.7 CompactFlash slot 1..........................47 2.6.8 CompactFlash slot 2..........................47 2.6.9 MIC, Line IN, Line OUT........................48 2.6.10 Add-on UPS slot..........................48 2.6.11 Power button............................49 2.6.12 Reset button............................49 2.6.13 LED status indicators..........................50 Panel PC 800 User's Manual V1.30...
  • Page 4 3.9.4 5AC801.HDDI-04...........................91 3.9.5 5AC801.SSDI-00........................... 93 3.9.6 5AC801.SSDI-01........................... 97 3.9.7 5AC801.SSDI-02........................... 99 3.9.8 5AC801.SSDI-03..........................101 3.9.9 5AC801.SSDI-04..........................104 3.9.10 5AC801.SSDI-05..........................107 3.9.11 5MMSSD.0060-00..........................109 3.9.12 5MMSSD.0060-01..........................111 3.9.13 5MMSSD.0128-01..........................114 3.9.14 5MMSSD.0180-00..........................117 3.9.15 5MMSSD.0256-00..........................119 Panel PC 800 User's Manual V1.30...
  • Page 5 5.5 One AP900 and one AP800 via onboard SDL..................168 5.5.1 Base system requirements......................... 168 5.5.2 Link modules............................168 5.5.3 Cables..............................168 5.5.4 Settings in BIOS..........................169 5.6 Four Automation Panel 900 systems via onboard SDL................170 5.6.1 Base system requirements......................... 170 Panel PC 800 User's Manual V1.30...
  • Page 6 1.4.10 Keyboard/Mouse configuration......................205 1.4.11 Remote access configuration......................206 1.4.12 CPU board monitor........................... 207 1.4.13 Baseboard/Panel features.........................208 1.5 Boot................................212 1.6 Security..............................213 1.7 Hard disk security user password......................214 1.8 Hard disk security master password......................215 1.9 Power................................215 Panel PC 800 User's Manual V1.30...
  • Page 7 6 Windows XP Embedded..........................241 6.1 General information..........................241 6.2 Order data..............................241 6.3 Overview..............................241 6.4 Features with FP2007 (Feature Pack 2007)....................241 6.5 Installation..............................242 6.6 Drivers...............................242 6.6.1 Touch screen driver..........................242 7 Windows Embedded Standard 2009......................243 Panel PC 800 User's Manual V1.30...
  • Page 8 1 Standards and guidelines..........................267 1.1 CE mark..............................267 1.2 EMC directive............................267 1.3 Low voltage directive..........................267 2 Certifications..............................268 2.1 UL certification............................268 2.2 GOST-R..............................268 Chapter 6 Accessories.................... 269 1 Replacement CMOS batteries........................269 1.1 0AC201.91 / 4A0006.00-000........................269 Panel PC 800 User's Manual V1.30...
  • Page 9 6.7 5AC600.UPSF-01............................. 282 6.7.1 General information..........................282 6.7.2 Order data............................282 7 External UPS..............................283 7.1 General information..........................283 7.2 Order data..............................283 8 PCI plug-in cards............................285 8.1 5ACPCI.ETH1-01............................285 8.1.1 General information..........................285 8.1.2 Order data............................285 Panel PC 800 User's Manual V1.30...
  • Page 10 10.2.3 Technical data...........................309 10.2.4 Temperature/Humidity diagram......................310 11 USB media drive............................311 11.1 5MD900.USB2-02........................... 311 11.1.1 General information...........................311 11.1.2 Order data............................311 11.1.3 Interfaces............................311 11.1.4 Technical data........................... 311 11.1.5 Dimensions............................313 11.1.6 Dimensions with front cover......................313 Panel PC 800 User's Manual V1.30...
  • Page 11 10 Installing and replacing bus units........................ 354 10.1 Procedure............................... 354 11 Installing and replacing adapters......................... 355 11.1 Procedure for the 5AC803.BC01-00 adapter..................355 11.2 Procedure for the 5AC803.BC02-00 adapter..................356 12 Installing and replacing PCIec plug-in cards....................357 Panel PC 800 User's Manual V1.30...
  • Page 12 6 Mounting compatibility............................368 6.1 Compatibility overview..........................368 6.2 Compatibility details..........................369 6.2.1 Example...............................369 6.2.2 5.7" devices............................369 6.2.3 10.4" devices............................371 6.2.4 12.1" devices............................372 6.2.5 15" devices............................373 6.2.6 17" devices............................374 6.2.7 19" devices............................374 6.2.8 21.3" devices............................375 7 Glossary................................. 376 Panel PC 800 User's Manual V1.30...
  • Page 13: Chapter 1 General Information

    Corrected service life of the battery. • Corrected chipset information for "CPU boards 945GME" on page 65. • Revised "Configuration - Optional components" on page 27. • Updated information about "Pixel errors" on page 181. Table 1: Manual history Panel PC 800 User's Manual V1.30...
  • Page 14 Updated replacement SSDs "5MMSSD.0060-00" on page 109, "5MMSSD.0060-01" on page 111 and "5MMSSD.0180-00" on page 117. • Updated technical data for HDD "5AC801.HDDI-04" on page 91. • Modified the ambient temperature tables in section "Temperature specifications" on page 28 Table 1: Manual history Panel PC 800 User's Manual V1.30...
  • Page 15 • Updated the new revisions of 5CFCRD.xxxx-06 CompactFlash cards, see "5CFCRD.xxxx-06" on page 293. • Updated technical data for system units "5PC820.1505-00" on page 53 and "5PC820.1906-00" on page 59. Table 1: Manual history Panel PC 800 User's Manual V1.30...
  • Page 16: Safety Guidelines

    Electronic devices are never completely failsafe. If the programmable control system, operating/monitoring device or uninterruptible power supply fails, the user is responsible for ensuring that other connected devices, e.g. motors, are brought to a secure state. Panel PC 800 User's Manual V1.30...
  • Page 17: Transport And Storage

    (e.g. diskette, CD-ROM, USB flash drive, etc.), a network connection or the Internet. The user is responsible for assessing these dangers, implementing preventive measures such as virus protection programs, firewalls, etc. and making sure that software is only obtained from trusted sources. Panel PC 800 User's Manual V1.30...
  • Page 18: Environmentally Friendly Disposal

    Uninterruptible power supply Batteries and rechargeable batteries Cables Cardboard box / paper packaging Paper / cardboard recycling Plastic packaging Plastic recycling Table 2: Environmentally friendly separation of materials Disposal must comply with applicable legal regulations. Panel PC 800 User's Manual V1.30...
  • Page 19: Organization Of Safety Notices

    For 6 to 30 mm ±0.2 mm For 30 to 120 mm ±0.3 mm For 120 to 400 mm ±0.5 mm For 400 to 1000 mm ±0.8 mm Table 4: Range of nominal sizes Panel PC 800 User's Manual V1.30...
  • Page 20: Overview

    CompactFlash 256 MB Western Digital (SLC) 5CFCRD.0512-03 CompactFlash 512 MB Western Digital (SLC) 5CFCRD.0512-04 CompactFlash 512 MB B&R (SLC) 5CFCRD.1024-03 CompactFlash 1 GB Western Digital (SLC) 5CFCRD.1024-04 CompactFlash 1 GB B&R (SLC) 5CFCRD.2048-03 CompactFlash 2 GB Western Digital (SLC) Panel PC 800 User's Manual V1.30...
  • Page 21 RS232 extension cable for remote operation of a display unit with touch screen, 1.8 m 9A0014.05 RS232 extension cable for remote operation of a display unit with touch screen, 5 m 9A0014.10 RS232 extension cable for remote operation of a display unit with touch screen, 10 m Panel PC 800 User's Manual V1.30...
  • Page 22 Microsoft OEM Windows 7 Ultimate 32-bit, Service Pack 1, DVD, multilingual. Only available with a new device. 5SWWI7.1400-MUL Microsoft OEM Windows 7 Ultimate 64-bit, Service Pack 1, DVD, multilingual. Only available with a new device. Panel PC 800 User's Manual V1.30...
  • Page 23 5SWWXP.0600-GER Microsoft OEM Windows XP Professional Service Pack 3, CD, German. Only available with a new device. 5SWWXP.0600-MUL Microsoft OEM Windows XP Professional Service Pack 3, CD, multilingual. Only available with a new device. Panel PC 800 User's Manual V1.30...
  • Page 24: Chapter 2 Technical Data

    Chapter 2 • Technical data 1 Introduction The Panel PC 800 covers an extremely wide performance range – relying on efficient Intel Atom N270 processors and Core2 Duo processors for applications with exceptionally high performance requirements. Brilliant 15" XGA and 19" SXGA touch screen displays provide a simple and intuitive user interface. Flexibility was raised to a com- pletely new level when designing the PPC800.
  • Page 25: Features

    • 2x Ethernet 10/100/1000 Mbit interfaces • 1x RS232 interface, modem-compatible • 24 VDC supply voltage • BIOS (AMI) • Real-time clock (RTC, battery-backed) • Easy slide-in drive replacement (SATA hot plugging) • HDA sound • Add-on UPS slot Panel PC 800 User's Manual V1.30...
  • Page 26: System Components / Configuration

    Select 1 5AC803.HS00-01 5AC803.HS00-02 5AC803.HS00-00 Main memory Select 1 or 2 (max. 3 GB can be used) 5MMDDR.0512-01 - 512 MB 5MMDDR.1024-01 - 1 GB 5MMDDR.2048-01 - 2 GB Figure 1: Configuration - Base system Panel PC 800 User's Manual V1.30...
  • Page 27: Configuration - Optional Components

    If both adapters are used, then a PCIec plug-in card and a slide-in compact drive can be operated in a single device. 2) A fan kit may be necessary for certain system configurations. Figure 2: Configuration - Optional components Panel PC 800 User's Manual V1.30...
  • Page 28: Complete System

    (serial interfaces, slide-in drives, USB ports, audio outputs) • Maximum system expansion and power consumption What must be considered when determining the maximum ambient temperature? • Operating the complete system with or without fan kit Panel PC 800 User's Manual V1.30...
  • Page 29: Maximum Ambient Temperature

    ✓ 5ACPCI.RAIC-06 (24 hours / standard) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1) Only possible with a CompactFlash card from B&R that is compatible with the device. Table 5: Ambient temperatures Panel PC 800 User's Manual V1.30...
  • Page 30 3. Incorporating additional drives (slide-in), main memory, additional plug-in cards, etc. can change the temper- ature limits of a PPC800 system. If there is a "✓" next to the component, it can be used at the maximum ambient temperature of the complete system without problems. Panel PC 800 User's Manual V1.30...
  • Page 31: Minimum Ambient Temperatures

    The temperature measured approximates the immediate ambient temperature but may also be influenced by neighboring components. The ADI driver containing the B&R Control Center is available in the Downloads section of the B&R website (www.br-automation.com). Panel PC 800 User's Manual V1.30...
  • Page 32: Humidity Specifications

    The specifications listed correspond to the relative humidity at an ambient temperature of 30°C. More detailed information about specific temperature-dependent humidity values can be found in the technical data for the indi- vidual components. Panel PC 800 User's Manual V1.30...
  • Page 33: Power Management

    5 V output, another DC-to-DC converter generates -12 V and applies this to the bus. An additional DC-to-DC converter generates +12 V. The optional add-on UPS (with battery unit) is supplied with 15 V and provides an uninterrupted power supply of the 15 V bus during a power failure. Panel PC 800 User's Manual V1.30...
  • Page 34: Power Calculation With 5Pc820.1505-00

    Table 9: Power calculation for 15" PPC800 Information: The PCIec card must not consume more than a total of 4 W (12 V / 5 V / 3V3)! Panel PC 800 User's Manual V1.30...
  • Page 35: Power Calculation With 5Pc820.1906-00

    Table 10: Power calculation for 19" PPC800 Information: The PCIec card must not consume more than a total of 4 W (12 V / 5 V / 3V3)! Panel PC 800 User's Manual V1.30...
  • Page 36: Block Diagrams

    8 Bit Konfigurationsschalter PPC touch IF CMOS profile Switching und Config R´s PPC BKL DC/DC + 12V Switching Schnittstelle nach außen geführt Schnittstelle optional oder intern Figure 5: Block diagram with bus unit 5AC803.BX01-00 Panel PC 800 User's Manual V1.30...
  • Page 37: Bus Unit 5Ac803.Bx01-01

    8 Bit Konfigurationsschalter PPC touch IF CMOS profile Switching und Config R´s PPC BKL DC/DC + 12V Switching Schnittstelle nach außen geführt Schnittstelle optional oder intern Figure 6: Block diagram with bus unit 5AC803.BX01-01 Panel PC 800 User's Manual V1.30...
  • Page 38: Bus Unit 5Ac803.Bx02-00

    8 Bit Konfigurationsschalter PPC touch IF CMOS profile Switching und Config R´s PPC BKL DC/DC + 12V Switching Schnittstelle nach außen geführt Schnittstelle optional oder intern Figure 7: Block diagram with bus unit 5AC803.BX02-00 Panel PC 800 User's Manual V1.30...
  • Page 39: Bus Unit 5Ac803.Bx02-01

    8 Bit Konfigurationsschalter PPC touch IF CMOS profile Switching und Config R´s PPC BKL DC/DC + 12V Switching Schnittstelle nach außen geführt Schnittstelle optional oder intern Figure 8: Block diagram with bus unit 5AC803.BX02-01 Panel PC 800 User's Manual V1.30...
  • Page 40: Serial Number Sticker

    The search provides a detailed list of installed components. Serial number entered here z.B.: AF210168454 wechseln auf den Tab „Serialnummer“ List of installed components shown after searching for a serial number Figure 10: Example of serial number search Panel PC 800 User's Manual V1.30...
  • Page 41: Device Interfaces And Slots

    The M4 self-locking nut can be used, for example, to fasten a copper strip to a central grounding point in the control cabinet or system where the PPC800 is installed. The largest possible conductor cross section should be used (at least 2.5 mm²). Panel PC 800 User's Manual V1.30...
  • Page 42: Monitor/Panel Interface

    Information: In SDL mode, the USB transfer rate is limited to USB 1.1. In DVI mode, the maximum USB transfer rate is determined by the USB interface and USB hub on the display device. Panel PC 800 User's Manual V1.30...
  • Page 43 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 Table 15: Cable lengths and resolutions for DVI transmission The maximum cable length for DVI transfer is limited to 5 m due to the USB specification. Panel PC 800 User's Manual V1.30...
  • Page 44: Com1 Serial Interface

    Table 16: COM1 - Pinout The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by the particular operating system. Panel PC 800 User's Manual V1.30...
  • Page 45: Ethernet 1 Interface (Eth1)

    Required drivers can only be downloaded from the B&R website, not from manufacturer websites. The PPC800 features a USB 2.0 (Universal Serial Bus) host controller with multiple USB ports, 5 of which are accessible externally for the user. Panel PC 800 User's Manual V1.30...
  • Page 46 The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by the particular operating system. Each USB port is protected by a maintenance-free "USB current-limiting circuit breaker" (max. 1 A). Panel PC 800 User's Manual V1.30...
  • Page 47: Compactflash Slot 1

    CompactFlash 1024 MB WD 5CFCRD.2048-03 CompactFlash 2048 MB WD 5CFCRD.4096-03 CompactFlash 4096 MB WD 5CFCRD.8192-03 CompactFlash 8192 MB WD Table 22: CompactFlash slot (CF2) Warning! An- und Abstecken der CompactFlash-Karte darf nur in spannungslosem Zustand erfolgen! Panel PC 800 User's Manual V1.30...
  • Page 48: Mic, Line In, Line Out

    Add-on UPS module 5AC600.UPSB-00 Battery unit 5 Ah 5CAUPS.0005-00 UPS cable 0.5 m 5CAUPS.0030-00 UPS cable 3 m Table 24: Add-on UPS slot For additional information about the UPS module, see "Accessories" on page 269. Panel PC 800 User's Manual V1.30...
  • Page 49: Power Button

    Pushing the reset button triggers a hardware and PCI reset. The PPC800 is restarted (cold restart). Pressing the reset button does not reset the MTCX processor. Table 26: Reset button Warning! A system reset can result in lost data! Panel PC 800 User's Manual V1.30...
  • Page 50: Led Status Indicators

    The factory default switch position represents the optimal BIOS default values for this system and should therefore not be changed. The position of the CMOS profile switch is displayed in BIOS Setup and in the B&R ADI Control Center. Panel PC 800 User's Manual V1.30...
  • Page 51: Battery

    From the point when battery capacity is recognized as insufficient, data buffering is intact for approximately another 500 hours. When replacing the battery, data is buffered for approximately 10 minutes by a gold leaf capacitor. Panel PC 800 User's Manual V1.30...
  • Page 52: Slide-In Compact Slot

    The adapter 5AC803.BC01-00 is required to use PCIec plug-in cards. Information: Only B&R PCIec cards that have been specially designed for the Automation PC 820 and Panel PC 800 can be used. For more information, see "PCIec plug-in cards" on page 78. Panel PC 800 User's Manual V1.30...
  • Page 53: Individual Components

    5AC803.HS00-02 PPC800 heat sink for CPU board with Atom processor N270 Fan kit 5AC803.FA01-00 PPC800 fan kit for system units without an expansion Optional accessories Adapters Table 33: 5PC820.1505-00 - Order data Panel PC 800 User's Manual V1.30...
  • Page 54 H0), 5PC600.SX05-00 (starting with Rev. F0), 5PC600.SX05-01 (starting with Rev. F0), 5PC600.SF03-00 (starting with Rev. A0), 5PC810.SX*. 5PC820.1505-00, 5PC820.1906-00. Order cable (5CAUPS.0005-00 or 5CAUPS.0030-00) and battery unit (5AC600.UPSB-00) separately Table 33: 5PC820.1505-00 - Order data Panel PC 800 User's Manual V1.30...
  • Page 55 Renata 950 mAh Service life 2½ years Removable Yes, accessible from the outside Design Lithium ion Power button Reset button Buzzer Certification cULus GOST-R Controller Boot loader BIOS Table 34: 5PC820.1505-00, 5PC820.1505-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 56 Electrical isolation Operating conditions Height of drop 1 m on industrial surfaces (in original packaging) EN 60529 protection Back: IP20 Front: IP65, dust and sprayed water protection Table 34: 5PC820.1505-00, 5PC820.1505-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 57 The PCI slots available depend on the expansion and bus unit being used. The PCIe slots available depend on the expansion and bus unit being used. Optional with PCIec adapter 5AC803.BC01-00. Optional with slide-in compact adapter 5AC803.BC02-00. Panel PC 800 User's Manual V1.30...
  • Page 58 81.7 5AC803.SX01-00 5AC803.SX02-00 Figure 14: 5PC820.1505 - Dimensions 3.1.1.6 Cutout Outer contour (Panel PC 800) Cutout Cutout size 415 ±0.5 mm x 312 ±0.5 mm suitable for 5PC820.1505-00 Figure 15: 5PC820.1505-00 - Cutout installation Panel PC 800 User's Manual V1.30...
  • Page 59: 5Pc820.1906-00

    1 compact PCI Express PPC800 adapter 5AC803.BC02-00 1 compact slide-in PPC800 adapter Bus units 5AC803.BX01-00 PPC800 bus; 1 PCI, 1 slide-in slot 5AC803.BX01-01 PPC800 bus; 1 PCI Express, 1 slide-in slot Table 35: 5PC820.1906-00 - Order data Panel PC 800 User's Manual V1.30...
  • Page 60 H0), 5PC600.SX05-00 (starting with Rev. F0), 5PC600.SX05-01 (starting with Rev. F0), 5PC600.SF03-00 (starting with Rev. A0), 5PC810.SX*. 5PC820.1505-00, 5PC820.1906-00. Order cable (5CAUPS.0005-00 or 5CAUPS.0030-00) and battery unit (5AC600.UPSB-00) separately Table 35: 5PC820.1906-00 - Order data Panel PC 800 User's Manual V1.30...
  • Page 61 Renata 950 mAh Service life 2½ years Removable Yes, accessible from the outside Design Lithium ion Power button Reset button Buzzer Certification cULus GOST-R Controller Boot loader BIOS Table 36: 5PC820.1906-00, 5PC820.1906-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 62 Electrical isolation Operating conditions Height of drop 1 m on industrial surfaces (in original packaging) EN 60529 protection Back: IP20 Front: IP65, dust and sprayed water protection Table 36: 5PC820.1906-00, 5PC820.1906-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 63 The PCI slots available depend on the expansion and bus unit being used. The PCIe slots available depend on the expansion and bus unit being used. Optional with PCIec adapter 5AC803.BC01-00. Optional with slide-in compact adapter 5AC803.BC02-00. Panel PC 800 User's Manual V1.30...
  • Page 64 5AC803.SX01-00 5AC803.SX02-00 Figure 18: 5PC820.1906-00 - Dimensions 3.1.2.6 Cutout Outer contour (Panel PC 800) 412.5 Cutout Cutout size 510 ±0.5 mm x 404 ±0.5 mm suitable for 5PC820.1906-00 Figure 19: 5PC820.1906-00 - Cutout installation Panel PC 800 User's Manual V1.30...
  • Page 65: Cpu Boards 945Gme

    Required accessories Main memory 5MMDDR.0512-01 SO-DIMM DDR2 RAM 512 MB PC2-5300 5MMDDR.1024-01 SO-DIMM DDR2 RAM 1024 MB PC2-5300 5MMDDR.2048-01 SO-DIMM DDR2 RAM 2048 MB PC2-5300 Table 38: 5PC800.B945-10, 5PC800.B945-11, 5PC800.B945-12, 5PC800.B945-13, 5PC800.B945-14 - Order data Panel PC 800 User's Manual V1.30...
  • Page 66: 5Pc800.B945-0X - Technical Data

    533 MHz 533 MHz 667 MHz Intel® 64 Architecture Intel® Virtualization Technology (VT-x) Enhanced Intel SpeedStep® Tech- nology Chipset Intel® 945GME Intel® 82801 GHM (ICH7M-DH) Table 40: 5PC800.B945-10, 5PC800.B945-11, 5PC800.B945-12, 5PC800.B945-13, 5PC800.B945-14 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 67 400 MHz RAMDAC, resolutions up to 2048 x 1536 @ 75 Hz (QXGA) and 1920 x 1080 @ 85 Hz (HDTV) Mass memory management 2x SATA, 1x IDE Power management ACPI 2.0, S3 Support (suspend to RAM) Table 40: 5PC800.B945-10, 5PC800.B945-11, 5PC800.B945-12, 5PC800.B945-13, 5PC800.B945-14 - Technical data Allocated in main memory. Panel PC 800 User's Manual V1.30...
  • Page 68: Heat Sink

    Suitable for the following system units 5PC820.1505-00 5PC820.1906-00 Certification Mechanical characteristics Materials Aluminum, black-coated with copper heat pipes Dimensions Width 143 mm Height 183.5 mm Depth 60 mm Weight 1200 g Table 42: 5AC803.HS00-00, 5AC803.HS00-01, 5AC803.HS00-02 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 69: Main Memory

    Table 44: 5MMDDR.0512-01, 5MMDDR.1024-01, 5MMDDR.2048-01 - Technical data Yes, although applies only if all components installed within the complete system have this certification Information: A main memory module can only be replaced at B&R. Panel PC 800 User's Manual V1.30...
  • Page 70: Expansions

    Slide-in slot 1 Figure 20: 5AC803.SX01-00, 5AC803.SX02-00 - Slots 3.5.4 Technical data Product ID 5AC803.SX01-00 5AC803.SX02-00 General information Certification GOST-R Inserts PCI / PCIe slots Quantity Slide-in drives Table 46: 5AC803.SX01-00, 5AC803.SX02-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 71: 5Ac803.Sx01-00 - Dimensions

    Mechanical characteristics Dimensions Width 167 mm Height 222 mm Depth 60 mm 80 mm Weight Approx. 1000 g Table 46: 5AC803.SX01-00, 5AC803.SX02-00 - Technical data 3.5.5 5AC803.SX01-00 - Dimensions Figure 21: 5AC803.SX01-00 - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 72: 5Ac803.Sx02-00 - Dimensions

    Standard PCI 2.2 half-size cards or PCI Express (PCIe) half-size cards can be installed depending on the type of bus unit. They cannot exceed the following dimensions. 177.7 17.4 25.8 Figure 23: Standard half-size PCI card - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 73 Technical data • Individual components 167.65 11.65 3.65 49.65 57.15 59.05 Figure 24: Standard half-size PCIe card - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 74: Slide-In Slot 1

    Table 47: Slide-in slot 1 Information: The SATA I interface allows disks to be replaced during operation (hot plugging). In order to take advantage of this capability, this feature must be supported by the operating system. Panel PC 800 User's Manual V1.30...
  • Page 75: Bus Units

    PPC800 bus; 1 PCI, 1 PCI Express, 1 slide-in slot Table 48: 5AC803.BX01-00, 5AC803.BX01-01, 5AC803.BX02-00, 5AC803.BX02-01 - Order data 3.6.3 Technical data Product ID 5AC803.BX01-00 5AC803.BX01-01 5AC803.BX02-00 5AC803.BX02-01 General information Certification GOST-R Table 49: 5AC803.BX01-00, 5AC803.BX01-01, 5AC803.BX02-00, 5AC803.BX02-01 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 76 33 MHz 33 MHz PCIe slots Quantity Design PCIe half-size PCIe half-size Standard 1.0 a 1.0 a Bus speed x1 (250 MB/s) x1 (250 MB/s) Table 49: 5AC803.BX01-00, 5AC803.BX01-01, 5AC803.BX02-00, 5AC803.BX02-01 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 77: Adapters

    5AC801.SSDI-00 32 GB SATA SSD (SLC), slide-in compact 5AC801.SSDI-03 60 GB SATA slide-in compact SSD (MLC) 5AC801.SSDI-04 128 GB SATA SSD (MLC), slide-in compact Table 51: 5AC803.BC02-00 - Order data Panel PC 800 User's Manual V1.30...
  • Page 78: Pciec Plug-In Cards

    19.8 11.65 64.9 Figure 27: PCI Express compact plug-in cards - Dimensions Information: Only B&R PCIec cards that have been specially designed for the Automation PC 820 and Panel PC 800 can be used. Panel PC 800 User's Manual V1.30...
  • Page 79: 5Acpcc.eth0-00

    The following characteristics, features and limit values only apply to this individual component and can deviate from those specified for the complete system. For the complete system in which this individual component is used, refer to the data given specifically for that device. Panel PC 800 User's Manual V1.30...
  • Page 80 A special driver is required in order to operate the Intel 82574 Ethernet controller. Drivers for approved operating systems are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
  • Page 81: 5Acpcc.mpl0-00

    The following characteristics, features and limit values only apply to this individual component and can deviate from those specified for the complete system. For the complete system in which this individual component is used, refer to the data given specifically for that device. Panel PC 800 User's Manual V1.30...
  • Page 82 If an error occurs in the following states, then the green LED blinks over the red LED: • BASIC_ETHERNET • PRE_OPERATIONAL_1 • PRE_OPERATIONAL_2 • READY_TO_OPERATE Status Green Error "S/E" LED Table 60: Status/Error LED as Error LED - POWERLINK V2 operating mode Panel PC 800 User's Manual V1.30...
  • Page 83 Error code indicated by red status LED RAM error • • • Pause • • • Pause Hardware error • • Pause • • Pause Table 62: Status/Error LED as Error LED - System failure error codes Panel PC 800 User's Manual V1.30...
  • Page 84 If the card is operated with Automation Runtime, then the card number switch must match the slot number in Automation Studio. Figure 29: Integrating the POWERLINK plug-in card in Automation Studio 3.8.4.3.5 SRAM The 2-port 5ACPCC.MPL0-00 POWERLINK card has 512 kB SRAM. Panel PC 800 User's Manual V1.30...
  • Page 85: Drives

    Typ. 3 s (from 0 rpm to read access) MTBF 750,000 POH S.M.A.R.T. support Interface SATA Access time 5.6 ms Data transfer rate Internal Max. 450 Mbit/s To/From host Max. 150 MB/s (Ultra DMA mode 5) Table 65: 5AC801.HDDI-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 86 Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 15% per hour. Slide-in compact installation. 3.9.1.4 Temperature humidity diagram Operation Temperature [°C] Figure 30: 5AC801.HDDI-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 87: 5Ac801.Hddi-02

    Max. 84.6 Mbit/s To/From host Max. 150 MB/s (Ultra DMA mode 5) Positioning time Minimum (track to track) 1.5 ms Nominal (read only) 12 ms Maximum (read only) 22 ms Table 67: 5AC801.HDDI-02 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 88 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 15% per hour. Maximum humidity at 29°C. Maximum humidity at 40°C. Slide-in compact installation. 3.9.2.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 31: 5AC801.HDDI-02 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 89: 5Ac801.Hddi-03

    PIO mode 0-4, multiword DMA mode 0-2, UDMA mode 0-6 Data transfer rate Internal Max. 1175 Mbit/s To/From host Max. 150 MB/s (SATA I), max. 300 MB/s (SATA II) Table 69: 5AC801.HDDI-03 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 90 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 30% per hour. Slide-in compact installation. 3.9.3.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 32: 5AC801.HDDI-03 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 91: 5Ac801.Hddi-04

    Internal Max. 147 MB/s To/From host Max. 150 MB/s (SATA I), max. 300 MB/s (SATA II) Positioning time Nominal (read only) 11 ms Maximum (read only) 21 ms Table 71: 5AC801.HDDI-04 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 92 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 20% per hour. Slide-in compact installation. 3.9.4.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 33: 5AC801.HDDI-04 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 93: 5Ac801.Ssdi-00

    <1 unrecoverable error in 10 bit read accesses MTBF 2,000,000 hours Power on/off cycles 50,000 S.M.A.R.T. support Interface SATA Maintenance None Sequential read Max. 250 MB/s Sequential write Max. 170 MB/s Table 73: 5AC801.SSDI-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 94 SSDSA2SH032G1 Table 73: 5AC801.SSDI-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. Slide-in compact installation. Panel PC 800 User's Manual V1.30...
  • Page 95 Technical data • Individual components 3.9.5.4 Temperature/Humidity diagram Storage Operation Transport Temperature [°C] Figure 34: 5AC801.SSDI-00 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 96 Transfer size [kB] 5AC801.SSDI-00 5AC801.HDDI-00 Figure 35: 5AC801.SSDI-00 - ATTO disk benchmark v2.34 - cyclic read 1024 2048 4096 8192 Transfer size [kB] 5AC801.SSDI-00 5AC801.HDDI-00 Figure 36: 5AC801.SSDI-00 - ATTO disk benchmark v2.34 - cyclic write Panel PC 800 User's Manual V1.30...
  • Page 97: 5Ac801.Ssdi-01

    Max. 550 MB/s with SATA 6 Gbit/s Max. 280 MB/s with SATA 3 Gbit/s Sequential write Max. 475 MB/s with SATA 6 Gbit/s Max. 245 MB/s with SATA 3 Gbit/s Table 75: 5AC801.SSDI-01 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 98 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. Slide-in compact installation. 3.9.6.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 37: 5AC801.SSDI-01 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 99: 5Ac801.Ssdi-02

    Max. 550 MB/s with SATA 6 Gbit/s Max. 280 MB/s with SATA 3 Gbit/s Sequential write Max. 520 MB/s with SATA 6 Gbit/s Max. 260 MB/s with SATA 3 Gbit/s Table 77: 5AC801.SSDI-02 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 100 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. Slide-in compact installation. 3.9.7.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 38: 5AC801.SSDI-02 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 101: 5Ac801.Ssdi-03

    Max. 25,000 (random) Endurance MLC flash Guaranteed data volume Guaranteed 35 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 79: 5AC801.SSDI-03, 5AC801.SSDI-03 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 102 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written Slide-in compact installation. 3.9.8.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 39: 5AC801.SSDI-03 ≤ Rev. C0 - Temperatur Luftfeuchtediagramm Panel PC 800 User's Manual V1.30...
  • Page 103 Technical data • Individual components Operation Temperature [°C] Figure 40: 5AC801.SSDI-03 ≥ Rev. D0 - Temperatur Luftfeuchtediagramm Panel PC 800 User's Manual V1.30...
  • Page 104: 5Ac801.Ssdi-04

    <1 unrecoverable error in 10 bit read accesses MTBF 1,500,000 hours S.M.A.R.T. support Interface SATA Maintenance None Sequential read Max. 510 MB/s Sequential write Max. 450 MB/s Table 81: 5AC801.SSDI-04, 5AC801.SSDI-04 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 105 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written Slide-in compact installation. 3.9.9.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 41: 5AC801.SSDI-04 ≤ Rev. C0 - Temperatur Luftfeuchtediagramm Panel PC 800 User's Manual V1.30...
  • Page 106 Technical data • Individual components Operation Temperature [°C] Figure 42: 5AC801.SSDI-04 ≥ Rev. D0 - Temperatur Luftfeuchtediagramm Panel PC 800 User's Manual V1.30...
  • Page 107: 5Ac801.Ssdi-05

    1,500,000 hours S.M.A.R.T. support Interface SATA Maintenance None Sequential read Max. 510 MB/s Sequential write Max. 460 MB/s IOPS 4k read Max. 90,000 (random) 4k write Max. 35,000 (random) Table 83: 5AC801.SSDI-05 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 108 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written Slide-in compact installation. 3.9.10.4 Temperature humidity diagram Operation Temperature [°C] Figure 43: 5AC801.SSDI-05 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 109: 5Mmssd.0060-00

    IOPS 4k read 15,000 4k write Typical 23,000 Maximum 80,000 Endurance MLC flash Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 85: 5MMSSD.0060-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 110 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. 3.9.11.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 44: 5MMSSD.0060-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 111: 5Mmssd.0060-01

    SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Environmental conditions Temperature Operation 0 to 70°C -30 to 85°C Storage -40 to 85°C Transport -40 to 85°C Table 87: 5MMSSD.0060-01, 5MMSSD.0060-01 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 112 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written 3.9.12.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 45: 5MMSSD.0060-01 ≤ Rev. C0 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 113 Technical data • Individual components Operation Temperature [°C] Figure 46: 5MMSSD.0060-01 ≥ Rev. D0 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 114: 5Mmssd.0128-01

    Max. 35,000 (random) Endurance MLC flash Guaranteed data volume Guaranteed 74 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 89: 5MMSSD.0128-01, 5MMSSD.0128-01 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 115 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written 3.9.13.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 47: 5MMSSD.0128-01 ≤ Rev. C0 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 116 Technical data • Individual components Operation Temperature [°C] Figure 48: 5MMSSD.0128-01 ≥ Rev. D0 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 117: 5Mmssd.0180-00

    IOPS 4k read 50,000 4k write Typical 60,000 Maximum 80,000 Endurance MLC flash Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 91: 5MMSSD.0180-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 118 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. 3.9.14.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 49: 5MMSSD.0180-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 119: 5Mmssd.0256-00

    4k write Max. 35,000 (random) Endurance MLC flash Guaranteed data volume Guaranteed 148 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 93: 5MMSSD.0256-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 120 Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written 3.9.15.4 Temperature humidity diagram Operation Temperature [°C] Figure 50: 5MMSSD.0256-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 121: 5Ac801.Adas-00

    Dimensions Width 22 mm Height 172.5 mm Depth 150 mm Weight 328 g Table 95: 5AC801.ADAS-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
  • Page 122: 5Ac801.Hdds-00

    Typ. 3 s (from 0 rpm to read access) MTBF 750,000 POH S.M.A.R.T. support Interface SATA Access time 5.6 ms Data transfer rate Internal Max. 450 Mbit/s To/From host Max. 150 MB/s (Ultra DMA mode 5) Table 97: 5AC801.HDDS-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 123 Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 15% per hour. Slide-in compact installation. 3.9.17.4 Temperature humidity diagram Operation Temperature [°C] Figure 51: 5AC801.HDDS-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 124: 5Ac801.Dvds-00

    Service life 60000 POH (power-on hours) Interface SATA Startup time Max. 19 seconds (from 0 rpm to read access) Max. 19 seconds (from 0 rpm to read access) Table 99: 5AC801.DVDS-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 125 Temperature [°C] Figure 52: 5AC801.DVDS-00 - Temperature humidity diagram 3.9.18.5 Hot plugging Hardware revision B0 of the 5AC801.DVDS-00 slide-in DVD-ROM does not offer SATA hot plugging functionality. Hot plugging is possible for other hardware revisions. Panel PC 800 User's Manual V1.30...
  • Page 126: 5Ac801.Dvrs-00

    Service life 60000 POH (power-on hours) Interface SATA Startup time Max. 14 seconds (from 0 rpm to read access) Max. 15 seconds (from 0 rpm to read access) Table 101: 5AC801.DVRS-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 127 Temperature specifications refer to operation at 500 meters. The maximum ambient temperature is typically derated by 1°C per 1000 meters (starting at 500 meters above sea level). Drive surface temperature. Panel PC 800 User's Manual V1.30...
  • Page 128 Technical data • Individual components 3.9.19.4 Temperature humidity diagram Storage Operation Temperature [°C] Figure 53: 5AC801.DVRS-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 129: 5Acpci.raic-03

    Optional accessories Drives 5ACPCI.RAIC-04 160 GB SATA hard disk, replacement part for 5ACPCI.RAIC-03; note: Please see the manual for information about using this hard disk. Table 102: 5ACPCI.RAIC-03 - Order data Panel PC 800 User's Manual V1.30...
  • Page 130 Max. 200 g, 0.5 ms; no damage Altitude Operation -300 to 3048 m Storage -300 to 12192 m Mechanical characteristics Installation Fixed Dimensions Width 70 mm Length 100 mm Height 9.5 mm Table 103: 5ACPCI.RAIC-03 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 131 The 160 GB 5ACPCI.RAIC-04 SATA HDD is available as a replacement hard disk. For instructions on replacing the drive, see 7 "Maintenance and service", section 14 "Replacing a PCI SATA RAID hard disk in a RAID 1 set" on page 359. Panel PC 800 User's Manual V1.30...
  • Page 132: 5Acpci.raic-04

    5 to 500 Hz: max. 5 g; duration 0.5 octaves per minute; no damage Transport 5 to 500 Hz: max. 5 g; duration 0.5 octaves per minute; no damage Table 105: 5ACPCI.RAIC-04 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 133 Maximum humidity at 40°C. Operation in areas prone to vibration and shock can affect performance negatively (reduction of transfer rate). 3.9.21.4 Temperature humidity diagram Operation Temperature [°C] Figure 56: 5ACPCI.RAIC-04 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 134: 5Acpci.raic-05

    Optional accessories Drives 5MMHDD.0250-00 250 GB SATA hard disk; replacement for 5AC801.HDDI-03 and 5ACPCI.RAIC-05; note: please see the manual for information about using this hard disk Table 106: 5ACPCI.RAIC-05 - Order data Panel PC 800 User's Manual V1.30...
  • Page 135 Temperature values at an elevation of 305 meters. The temperature specification must be reduced linearly by 1°C every 305 meters. The temperature increase and decrease can be a maximum of 20°C per hour. Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Panel PC 800 User's Manual V1.30...
  • Page 136 The 250 GB 5MMHDD.0250-00 SATA HDD is available as a replacement hard disk. For information about performing a replacement, see "Replacing a PCI SATA RAID hard disk in a RAID 1 set" on page 359. Panel PC 800 User's Manual V1.30...
  • Page 137: 5Acpci.raic-06

    Optional accessories Drives 5MMHDD.0500-00 500 GB SATA hard disk; replacement for 5AC801.HDDI-04, 5AC901.CHDD-01 and 5ACPCI.RAIC-06; note: please see the manual for information about using this hard disk Table 108: 5ACPCI.RAIC-06 - Order data Panel PC 800 User's Manual V1.30...
  • Page 138 1000 g and 2 ms duration; no unrecoverable errors Transport 1000 g and 2 ms duration; no unrecoverable errors Altitude Operation -305 to 3048 m Storage -305 to 12192 m Mechanical characteristics Installation Fixed Table 109: 5ACPCI.RAIC-06 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 139 The 500 GB 5MMHDD.0500-00 SATA HDD is available as a replacement hard disk. For information about performing a replacement, see "Replacing a PCI SATA RAID hard disk in a RAID 1 set" on page 359. Panel PC 800 User's Manual V1.30...
  • Page 140: 5Mmhdd.0250-00

    Max. 150 MB/s (SATA I), max. 300 MB/s (SATA II) Positioning time Minimum (track to track) 1 ms Nominal (read only) 14 ms Maximum (read only) 30 ms Table 111: 5MMHDD.0250-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 141 Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 30% per hour. 3.9.24.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 61: 5MMHDD.0250-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 142: 5Mmhdd.0500-00

    Typ. 3.5 s (from 0 rpm to read access) Service life 5 years MTBF 1,000,000 POH S.M.A.R.T. support Interface SATA Access time 5.5 ms Supported transfer modes SATA II Table 113: 5MMHDD.0500-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 143 Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 20% per hour. 3.9.25.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 62: 5MMHDD.0500-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 144: Fan Kit

    General information Number of fans Speed Max. 6100 rpm Noise level 21 dB Service life 29,000 hours at 70°C 95,000 hours at 20°C Type Double ball bearings Certification GOST-R Table 115: 5AC803.FA01-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 145: 5Ac803.Fa02-00

    Fan 3: 5 dB Service life Fans 1, 2: 29,000 hours at 70°C, 95,000 hours at 20°C Fan 3: 60,000 hours (at 40°C) Type Double ball bearings Certification GOST-R Table 117: 5AC803.FA02-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 146 Fans 1, 2: 40 mm Fan 3: 70 mm Height Fans 1, 2: 40 mm Fan 3: 70 mm Depth Fans 1, 2: 10 mm Fan 3: 15 mm Table 117: 5AC803.FA02-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 147: 5Ac803.Fa03-00

    Fan 4: 5 dB Service life Fan 1, 2, 3: 29,000 hours at 70°C, 95,000 hours at 20°C Fan 4: ±60,000 at 40°C Type Double ball bearings Certification GOST-R Table 119: 5AC803.FA03-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 148 Fan 1, 2, 3: 40 mm Fan 4: 70 mm Height Fan 1, 2, 3: 40 mm Fan 4: 70 mm Depth Fan 1, 2, 3: 10 mm Fan 4: 15 mm Table 119: 5AC803.FA03-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 149: Chapter 3 Installation

    Clamping blocks are designed to clamp a maximum thickness of 10 mm and minimum thickness of 2 mm. A hex key (3 mm) is needed to tighten and loosen the screws. The maximum torque when tightening the clamp is 0.5 Nm. Panel PC 800 User's Manual V1.30...
  • Page 150 Installation • Installation Devices must be installed on flat, clean and burr-free surface; uneven areas can cause damage to the display when the screws are tightened or intrusion of dust and water. Panel PC 800 User's Manual V1.30...
  • Page 151: Mounting Orientation

    Figure 67: Mounting orientation 0° and +/- 45° In order to facilitate natural air circulation, devices must be mounted according to the spacing indicated in the section "Spacing for air circulation" on page 154. Panel PC 800 User's Manual V1.30...
  • Page 152: Mounting Orientation With 5Ac801.Dvrs-00

    1.3.2 Mounting orientation with 5AC801.DVRS-00 0° Figure 68: Mounting orientation with 5AC801.DVRS-00 In order to facilitate natural air circulation, devices must be mounted according to the spacing indicated in the section "Spacing for air circulation" on page 154. Panel PC 800 User's Manual V1.30...
  • Page 153: Mounting Orientation With 5Ac801.Dvds-00

    1.3.3 Mounting orientation with 5AC801.DVDS-00 0° Figure 69: Mounting orientation with 5AC801.DVDS-00 In order to facilitate natural air circulation, devices must be mounted according to the spacing indicated in the section "Spacing for air circulation" on page 154. Panel PC 800 User's Manual V1.30...
  • Page 154: Spacing For Air Circulation

    In order to guarantee sufficient air circulation, allow the specified amount of space above, below, to the side and behind the Panel PC 800 devices. The minimum specified spacing is indicated in the following diagram. This applies to all Panel PC 800 variants.
  • Page 155: Cable Connections

    The maximum torque for the locating screws is 0.5 Nm. Locating screws Flex radius Locating screws Figure 71: Flex radius - Cable connection (sample image) Information: The specified flex radius is listed in the technical data for the respective cable. Panel PC 800 User's Manual V1.30...
  • Page 156: Grounding Concept

    • Note the line shielding concept; all connected data cables are used as shielded lines. Functional ground is indicated on the B&R device with the following symbol: Control cabinet Grounding strip Ground connection Power supply Min. 2.5 m m² Min. 2.5 m m² Figure 72: Grounding concept Panel PC 800 User's Manual V1.30...
  • Page 157: General Instructions For Performing Temperature Testing

    (www.br-automation.com). The B&R Control Center uses the B&R Automation Device Interface (ADI). A separate application can be developed if it is necessary to collect historical data. Information: Software development kits such as the ADI .NET SDK are available on the B&R website (www.br- automation.com). Panel PC 800 User's Manual V1.30...
  • Page 158: Evaluating With The Burnintest Tool From Passmark

    More information available www.passmark.com. The following screenshots are based on Passmark BurnInTest Pro V4 and a 2-slot APC810 with DVD. Figure 73: Settings for Passmark BurnInTest Pro V4 and a 2-slot APC810 with DVD Panel PC 800 User's Manual V1.30...
  • Page 159 Windows. The test USB must then be deselected, and the USB flash drives must be configured as the testing device in the disk properties. Information: Serial loopback plugs are relatively easy to create. Simply connect several pins on the serial interface with wires. Panel PC 800 User's Manual V1.30...
  • Page 160: Evaluating Temperatures In Operating Systems Other Than Windows

    76°C Board I/O 51°C 66°C 76°C Board ETH2 52°C 67°C 77°C Board power supply 51°C 66°C 76°C ETH2 65°C 80°C 90°C Power supply 51°C 66°C 76°C Table 120: Evaluation example using a 2-slot APC810 Panel PC 800 User's Manual V1.30...
  • Page 161: Connection Examples

    The following table lists the AP900 devices that can be connected on the same line with an AP800 device. Automation Panel 800 Automation Panel 900 5AP820.1505-00 5AP920.1505-01 5AP951.1505-01 5AP980.1505-01 5AP981.1505-01 5AP880.1505-00 5AP920.1505-01 5AP951.1505-01 5AP980.1505-01 5AP981.1505-01 Table 121: Selecting display units Panel PC 800 User's Manual V1.30...
  • Page 162: One Automation Panel 900 System Via Onboard Dvi

    DVI-D cable, 10 m 10 m ±100 mm 9A0014.02 RS232 extension cable for remote operation of a display unit with touch screen, 1.8 m 1.8 m ±50 mm Table 124: Cables for DVI configurations Panel PC 800 User's Manual V1.30...
  • Page 163: Possible Automation Panel Devices, Resolutions And Segment Lengths

    USB support is not possible on the Automation Panel 900 in these cases since USB is limited to 5 m. Information: When transferring data via DVI, it is not possible to read statistical values from Automation Panel 900 devices. 5.2.5 BIOS settings No special BIOS settings are necessary for operation. Panel PC 800 User's Manual V1.30...
  • Page 164: One Automation Panel 900 System Via Onboard Sdl

    SDL cable, 30 m 30 m ±100 mm 5CASDL.0018-03 SDL flex cable, 1.8 m 1.8 m ±20 mm 5CASDL.0050-03 SDL flex cable, 5 m 5 m ±45 mm Table 128: Cables for SDL configurations Panel PC 800 User's Manual V1.30...
  • Page 165: Settings In Bios

    For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Panel PC 800 User's Manual V1.30...
  • Page 166: One Automation Panel 800 System Via Onboard Sdl

    PDF file from the B&R website at www.br-automation.com. 5.4.2.1 Cable lengths and resolutions for SDL transmission The following table lists the relationship between segment lengths and maximum resolution depending on the SDL cable being used: Panel PC 800 User's Manual V1.30...
  • Page 167: Settings In Bios

    For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Panel PC 800 User's Manual V1.30...
  • Page 168: One Ap900 And One Ap800 Via Onboard Sdl

    For a selection of SDL cables for connecting the AP900 display to an AP900 display, see "Cables" on page 164. For a selection of SDL cables for connecting the AP800 display to an AP900 display, see "Cables" on page 166. Information: For detailed information regarding cables, see the chapter "Accessories". Panel PC 800 User's Manual V1.30...
  • Page 169: Settings In Bios

    For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Panel PC 800 User's Manual V1.30...
  • Page 170: Four Automation Panel 900 Systems Via Onboard Sdl

    Connections for SDL In and SDL Out; transmission of display, touch screen, USB 1.1, matrix key and service data; 24 VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately) Table 136: Link modules 5.6.3 Cables Select an Automation Panel 900 cable from the following table. Panel PC 800 User's Manual V1.30...
  • Page 171: Settings In Bios

    For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Panel PC 800 User's Manual V1.30...
  • Page 172: Touch Screen Calibration

    Windows CE starts the touch screen calibration sequence during its first boot in its default configuration (i.e. de- livered state). 6.7 Automation Runtime / Visual Components The touch screen must be calibrated once for the customer application when commissioning the device and project. Panel PC 800 User's Manual V1.30...
  • Page 173: Connecting Peripheral Usb Devices

    7.1 Locally on the PPC800 Many different peripheral USB devices can be connected to the 5 USB interfaces on the Panel PC 800. These can each handle a load of up to 1 A. The maximum transfer rate is USB 2.0.
  • Page 174: Remote Connection To Automation Panel 900 Via Dvi

    USB memory media e.g. flash drive USB input devices USB drives USB pointing devices e.g. keyboard e.g. CD-ROM drive e.g. mouse Figure 81: Remote connection of USB peripheral devices on the APC900 via DVI Panel PC 800 User's Manual V1.30...
  • Page 175: Remote Connection To Automation Panel 800 / 900 Via Sdl

    USB memory media e.g. flash drive USB drives USB input devices USB pointing devices e.g. CD-ROM drive e.g. keyboard e.g. mouse Figure 82: Remote connection of USB peripheral devices on the APC800/900 via SDL Panel PC 800 User's Manual V1.30...
  • Page 176: Configuring A Sata Raid Set

    Moves to the next item Enter Selects an item or opens a submenu Returns to the previous menu Ctrl+E Saves any changed settings and exits setup Table 139: BIOS-relevant keys in the RAID Configuration Utility Panel PC 800 User's Manual V1.30...
  • Page 177: Create Raid Set

    Figure 86: RAID Configuration Utility - Create RAID set - Striped "Auto configuration" Auto configuration optimizes all settings. "Manual configuration" Allows the first and second HDD to be specified as well as the "Chunk size" (= block size, application-dependent). Panel PC 800 User's Manual V1.30...
  • Page 178: Create Raid Set - Mirrored

    1 ST96023AS Chunk Size Previous Menu Enter Select Ctrl-E Exit First HDD Figure 88: RAID Configuration Utility - Delete RAID set An existing RAID set can be deleted using the "Delete RAID set" menu option. Panel PC 800 User's Manual V1.30...
  • Page 179: Rebuild Mirrored Set

    Figure 90: RAID Configuration Utility - Resolve conflicts Conflicts in a RAID set can be resolved using the "Resolve conflicts" menu option. This function is only available if the status of the hard disk is "Conflict". Panel PC 800 User's Manual V1.30...
  • Page 180: Low Level Format

    Individual hard disks can be configured using the "Low level format" menu option. This can only be done if a RAID set is not configured. A low level format of a hard disk takes approx. 40 minutes. Panel PC 800 User's Manual V1.30...
  • Page 181: User Tips For Increasing The Display Lifespan

    • By using a screensaver 10 Pixel errors Information: Displays may contain defective pixels (dead/stuck pixels) that result from the manufacturing process. These flaws are not grounds for reclamation or initiating a warranty claim. Panel PC 800 User's Manual V1.30...
  • Page 182: Known Problems/Issues

    (e.g. Windows XP boot logo). HD resolution is displayed corrected again when Windows XP or Windows 7 is booted properly with an installed graphics driver. Panel PC 800 User's Manual V1.30...
  • Page 183: Chapter 4 Software

    To enter BIOS Setup, the <Del> key must be pressed after the USB controller has been initialized as soon as the following message appears on the screen (during POST): "Press DEL to run SETUP". Panel PC 800 User's Manual V1.30...
  • Page 184 Auto-Detecting Sec Slave...IDE Hard Disk Sec Master: SILICONSYSTEMS INC 4GB 240-0230 Sec Slave : SILICONSYSTEMS INC 4GB 240-0230 Auto-Detecting USB Mass Storage Devices .. 00 USB mass storage devices found an configured. Figure 92: Boot Screen Panel PC 800 User's Manual V1.30...
  • Page 185: Bios Setup Keys

    Jumps to the last BIOS menu item or object F2 / F3 Changes the colors of BIOS Setup Resets any changes Loads and configures CMOS default values for all BIOS settings Saves and exits Exits a submenu Table 141: BIOS-relevant keys Panel PC 800 User's Manual V1.30...
  • Page 186: Main

    Boot counter Displays the boot counter; each restart increases None the counter by one (max. 16777215) Running time Displays the runtime in hours (max. 65535) None Table 142: 945GME Main menu - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 187: Advanced

    "CPU board monitor" on page 207 Baseboard/Panel fea- Displays and configures device-specific settings Enter Opens the submenu tures see "Baseboard/Panel features" on page 208 Table 143: 945GME Advanced menu Panel PC 800 User's Manual V1.30...
  • Page 188: Acpi Configuration

    80°C, 85°C, 90°C, 95°C, Temperature setting for the critical trip point. which the operating system automatically shuts 100°C, 105°C, 110°C Configurable in increments of 5 degrees. down Table 144: 945GME Advanced - ACPI configuration - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 189: Pci Configuration

    "PCI IRQ resource exclusion" on page PCI interrupt routing Configures PCI interrupt routing Enter Opens the submenu see "PCI interrupt routing" on page 191 Table 145: 945GME Advanced - PCI configuration - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 190 IRQ interrupt routing for Legacy ISA devices Allocated Allocated by the system - cannot be used Available Available - can be used Reserved Reserved - cannot be used Table 146: 945GME Advanced - PCI IRQ resource exclusion - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 191 Assigns the PIRQ as the 1st exclusive PCI IRQ sharing). Information: This is only displayed if a PIRQ is con- figured manually (e.g. 5). Table 147: 945GME Advanced - PCI interrupt routing - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 192 PCIE port 2 (IF slot) This option enables or disables the PCI Express Auto Automatic assignment by BIOS and the operat- interface function. ing system Table 148: 945GME Advanced - PCI Express configuration - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 193 Programmable Interrupt Controller) on Disabled Disables this function PCIE port 3. The IRQ resources available to the system are expanded when APIC mode is en- abled. Table 148: 945GME Advanced - PCI Express configuration - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 194: Graphics Configuration

    Local flat panel type This option can be used to set a predefined profile Auto Automatic detection and configuration using the for the LVDS channel. EDID data Table 149: 945GME Advanced - Graphics configuration - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 195 DVI monitors are reconnected, even if only one of them was connected and enabled during a previ- ous boot. Table 149: 945GME Advanced - Graphics configuration - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 196: Cpu Configuration

    Disables C3 support C4 config Power management for the Intel Core Duo Standard Standard C4 support processor Enhanced Enhanced C4 support Disabled Disables C4 support Table 150: 945GME Advanced - CPU configuration - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 197: Chipset Configuration

    Fine-tunes the power saving function on an ACPI Enabled Brings the processor to C4 if the operating sys- operating system tem is initiated in a C3 state Disabled Disables this function Table 151: 945GME Advanced - Chipset settings - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 198: I/O Interface Configuration

    Clock Configuration Enable clock modulation to reduce Spread Spectrum [Disabled] EMI. Select Screen Select Item Change Option General Help Save and Exit Exit v02.59 (C)Copyright 1985-2005, American Megatrends, Inc. Figure 104: 945GME Advanced Clock Configuration Panel PC 800 User's Manual V1.30...
  • Page 199: Ide Configuration

    Enables this function the hard drive Disabled Disables this function IDE detect time out (sec) Configures the time overrun limit for ATA/ATAPI 0, 5, 10, 15, 20, 25, 30, 35 Time setting in seconds device detection. Panel PC 800 User's Manual V1.30...
  • Page 200 Enables this function Disabled Disables this function 32 bit data transfer Enables 32-bit data transfer Enabled Enables this function Disabled Disables this function Table 154: 945GME Advanced - Primary IDE master - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 201 Enables this function Disabled Disables this function 32 bit data transfer Enables 32-bit data transfer Enabled Enables this function Disabled Disables this function Table 155: 945GME Advanced - Primary IDE slave - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 202 Enables this function Disabled Disables this function 32 bit data transfer Enables 32-bit data transfer Enabled Enables this function Disabled Disables this function Table 156: 945GME Advanced - Secondary IDE master - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 203 Enables this function Disabled Disables this function 32 bit data transfer Enables 32-bit data transfer Enabled Enables this function Disabled Disables this function Table 157: 945GME Advanced - Secondary IDE slave - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 204: Usb Configuration

    Hard disk drive An HDD-formatted drive can be used as an FDD (e.g. zip drive) to start the system. Table 158: 945GME Advanced - USB configuration - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 205: Keyboard/Mouse Configuration

    Enables the numeric keypad Typematic rate Configures the key repeat function Slow Slow key repeat Fast Fast key repeat Table 159: 945GME Advanced - Keyboard/Mouse configuration - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 206: Remote Access Configuration

    Loads updates to the processor via the serial in- Enabled Enables this function terface during system startup Disabled Disables this function Information: Disabling this option reduced the boot time. Table 160: 945GME Advanced - Remote access configuration - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 207: Cpu Board Monitor

    Displays the current voltage of the 5 volt supply None +12Vin Displays the current voltage of the 12 volt supply None VRTC Displays the battery voltage in volts None Table 161: 945GME Advanced - CPU board monitor - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 208: Baseboard/Panel Features

    (e.g. to give the device a unique ID) and can only be changed using the "B&R Control Center" includ- ed with the ADI driver. Table 162: 945GME Advanced - Baseboard/Panel features - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 209 Fan speed Displays the fan speed for the selected panel None Keys/LEDs Displays the available keys and LEDs on the se- None lected panel Table 163: 945GME Advanced - Panel control - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 210 Displays the speed of housing fan 2 None Case 3 Displays the speed of housing fan 3 None Case 4 Displays the speed of housing fan 4 None Table 164: 945GME Advanced - Baseboard monitor - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 211 Enables the controller (ETH2) on and off Disabled Disables the controller ETH2 MAC address Displays the MAC address of the Ethernet 2 con- None troller Table 165: 945GME Advanced - Legacy devices - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 212: Boot

    This option can be used to attempt to restart the Enabled Enables this function operating system automatically if it fails to start Disabled Disables this function the first time. Table 166: 945GME Boot menu - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 213: Security

    BIOS settings. Change user password Function for entering/changing a user password. Enter Password entry The user password allows the user to edit only certain BIOS settings. Table 167: 945GME Security menu - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 214: Hard Disk Security User Password

    The user password allows the user to edit only certain BIOS settings. Table 168: 945GME Security - Hard disk security user password Panel PC 800 User's Manual V1.30...
  • Page 215: Hard Disk Security Master Password

    Select Item Resume On PME# [Disabled] Change Option Resume On RTC Alarm [Disabled] General Help Save and Exit Power Button Mode [On/Off] Exit v02.59 (C)Copyright 1985-2005, American Megatrends, Inc. Figure 122: 945GME Power Menü Panel PC 800 User's Manual V1.30...
  • Page 216 Disabled Disables this function Power button mode This function determines what the power button On/Off Switches the system on/off does. Suspend Suppresses this function Table 170: 945GME Power menu - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 217: Exit

    This option loads the CMOS default values de- OK / Cancel fined by the DIP switch settings. These values are loaded for all BIOS settings. Table 171: 855GME (XTX) Exit menu - Configuration options Panel PC 800 User's Manual V1.30...
  • Page 218: Bios Default Settings

    Plug & Play O/S PCI latency timer Allocate IRQ to PCI VGA Allocate IRQ to SMBUS HC Allocate IRQ to PCIEX2 PCI IRQ resource exclusion Table 175: 945GME Advanced - PCI configuration - Overview of profile settings Panel PC 800 User's Manual V1.30...
  • Page 219 Disabled Execute disable bit Enabled Enabled Core multi-processing Enabled Enabled Intel(R) SpeedStep(tm) tech. Automatic Automatic Max. CPU frequency xxxx MHz xxxx MHz Table 178: 945GME Advanced - CPU configuration - Overview of profile settings Panel PC 800 User's Manual V1.30...
  • Page 220 PIO mode Auto Auto DMA mode Auto Auto S.M.A.R.T. Auto Auto 32Bit data transfer Enabled Enabled Secondary IDE slave Type Auto Auto Table 182: 945GME Advanced - IDE configuration - Overview of profile settings Panel PC 800 User's Manual V1.30...
  • Page 221 Board I/O Board ETH2 Board power Power supply Slide-in drive 1 IF slot Case 1 Case 2 Case 3 Case 4 Legacy devices Table 186: 945GME Advanced - Baseboard/Panel features - Overview of profile settings Panel PC 800 User's Manual V1.30...
  • Page 222: Boot

    Secondary slave IDE MONITOR MONITOR Resume on ring Disabled Disabled Resume on PME# Disabled Disabled Resume on RTC alarm Disabled Disabled Power button mode On/Off On/Off Table 189: 945GME Power - Overview of profile settings Panel PC 800 User's Manual V1.30...
  • Page 223: Bios Error Signals (Beep Codes)

    Send the industrial PC to B&R for testing. to CMOS 11x short Cache error / external cache bad: Defective L2 cache on the main- Send the industrial PC to B&R for testing. board Table 190: 945GME BIOS - POST messages Panel PC 800 User's Manual V1.30...
  • Page 224: Allocation Of Resources

    B&R COM5 ○ ○ ○ ○ ○ ○ ○ ○ ● (COM D) Table 193: IRQ interrupt assignments in PIC mode Advanced Configuration and Power Interface. ● ... Default setting ○ ... Optional setting Panel PC 800 User's Manual V1.30...
  • Page 225: Interrupt Assignments In Apic Mode

    APIC IRQ 22 PIRQ H USB UHCI-0 USB EHCI B0:D29:F0 B0:D29:F7 APIC IRQ 23 PCI 1 PCI 2 Figure 124: PCI and PCIe routing with enabled APIC for 945GME CPU boards and BIOS versions ≥ 1.15 Panel PC 800 User's Manual V1.30...
  • Page 226: Upgrade Information

    This information can be found on the following BIOS Setup screen: • After switching on the PPC800, BIOS Setup can be accessed by pressing <Del>. • From the BIOS main menu "Advanced", select "Baseboard/Panel features" and then "Panel control". Panel PC 800 User's Manual V1.30...
  • Page 227: Procedure With Ms-Dos

    5. The following boot menu will be shown after startup: 1. Upgrade AMI BIOS for B945 2. Exit Item 1: BIOS is automatically upgraded (default after 5 seconds). Item 2: Returns to the shell (MS-DOS) Panel PC 800 User's Manual V1.30...
  • Page 228 PC. 6. The system must be rebooted after a successful upgrade. 7. Reboot and press <Del> to enter BIOS Setup and load the setup defaults, then select "Save changes and exit". Panel PC 800 User's Manual V1.30...
  • Page 229: Firmware Upgrade

    Automatically updates the SDLR controller on the Automation Panel 3 interface 2.5 Upgrade all SDLR (AP800/AP900) Automatically updates all SDLR controllers on all Automation Panels on the monitor/panel interface (default selec- tion after 5 sec) Panel PC 800 User's Manual V1.30...
  • Page 230: Possible Upgrade Problems And Software Dependencies (For V1.02)

    MTCX or SDLT (to put the system in standby mode) before powering the system off and back on. If this is not done, the firmware upgrade will not work since the UPS is buffering the system. Panel PC 800 User's Manual V1.30...
  • Page 231: Creating An Ms-Dos Boot Diskette In Windows Xp

    In Windows Explorer, go to the "Tools" menu, select "Folder options" and open the "View" tab. Then deselect the option "Hide protected operating system files (Recommended)" (enabled by default) and enable the option "Show hidden files and folders". Panel PC 800 User's Manual V1.30...
  • Page 232 Figure 130: Creating a bootable diskette in Windows XP - Step 4 Figure 131: Creating a bootable diskette in Windows XP - Step 5 Now all files (selected) except Command.com, IO.sys and MSDOS.sys can be deleted. Panel PC 800 User's Manual V1.30...
  • Page 233: Creating A Bootable Usb Flash Drive For B&R Upgrade Files

    Information on creating an MS-DOS boot diskette can be found in section see "Creating an MS-DOS boot diskette in Windows XP" on page 231. The files from the diskette are then copied to the hard drive. Panel PC 800 User's Manual V1.30...
  • Page 234: Creating A Bootable Compactflash Card For B&R Upgrade Files

    Information on creating an MS-DOS boot diskette can be found in section see "Creating an MS-DOS boot diskette in Windows XP" on page 231. The files from the diskette are then copied to the hard drive. Panel PC 800 User's Manual V1.30...
  • Page 235: Microsoft Dos

    ✓ ✓ ✓ 1024 x 768 ✓ ✓ ✓ 1280 x 1024 ✓ ✓ ✓ 1600 x 1200 ✓ ✓ ✓ 1920 x 1440 Table 197: Tested resolutions and color depths for RGB signals Panel PC 800 User's Manual V1.30...
  • Page 236: Windows Xp Professional

    PPC900 PP500 5SWWXP.0500-GER Professional APC620 945GME SP2c German ≤2.1 GB 128 MB APC810 GM45 APC820 PPC700 PPC725 PPC800 5SWWXP.0500-ENG Professional APC620 945GME SP2c English ≤2.1 GB 128 MB APC810 GM45 APC820 PPC700 PPC725 PPC800 Panel PC 800 User's Manual V1.30...
  • Page 237: Installation

    4.5 Drivers Current drivers for all approved operating systems are available in the Downloads section of the B&R website www.br-automation.com. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
  • Page 238: Windows 7

    1 GB APC511 GM45 APC810 QM77/HM76 APC910 NM10 APC2100 US15W PPC800 Bay Trail PPC900 PPC2100 PP500 5SWWI7.0100-ENG Professional APC510 945GME 32-bit English 16 GB 1 GB APC511 GM45 APC810 QM77/HM76 APC910 US15W PPC800 PP500 Panel PC 800 User's Manual V1.30...
  • Page 239: Installation

    The memory used by additional language packs is not taken into account in the minimum size of the disk. 5.4 Installation All of the drivers required for operation (graphics, network, etc.) are also installed in this process. Panel PC 800 User's Manual V1.30...
  • Page 240: Installation On A Pci Sata Raid Controller - 5Acpci.raic-03, 5Acpci.raic-05

    5.6 Drivers Current drivers for all approved operating systems are available in the Downloads section of the B&R website www.br-automation.com. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
  • Page 241: Windows Xp Embedded

    Codepages / User locales / Keyboards ✓ Disk Management Service Windows Installer Service ✓ ✓ Class Installer ✓ CoDevice Installer Media Player DirectX Accessories ✓ Number of fonts Table 201: Device functions in Windows XP Embedded with FP2007 Panel PC 800 User's Manual V1.30...
  • Page 242: Installation

    Panel 900 touch screen devices. The driver is available in the Downloads section of the B&R website (www.br- automation.com). Be sure to check that the "Enhanced Write Filter (EWF)" is enabled. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
  • Page 243: Windows Embedded Standard 2009

    ✓ Terminal service ✓ Windows Firewall MSN Explorer Outlook Express ✓ Administrative Tools ✓ Remote Desktop Remote Assistance .NET Framework ASP.NET ✓ Local network bridge Table 203: Device functions in Windows Embedded Standard 2009 Panel PC 800 User's Manual V1.30...
  • Page 244: Installation

    Downloads section of the B&R website (www.br-automation.com). It is important that Enhanced Write Filter (EWF) is enabled for this. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
  • Page 245: Windows Embedded Standard 7

    Microsoft OEM Windows Embedded Standard 7 64-bit, Service Pack 1, Language Pack DVD Table 204: 5SWWI7.0527-ENG, 5SWWI7.1527-ENG, 5SWWI7.0627-ENG, 5SWWI7.1627-ENG, 5SWWI7.0727-MUL, 5SWWI7.1727-MUL, 5SWWI7.0827-MUL, 5SWWI7.1827-MUL - Order data 64-bit versions are not supported by all systems. Panel PC 800 User's Manual V1.30...
  • Page 246: Overview

    Wenn der EWF (Enhanced Write Filter) verwendet werden soll, sind während des Setup oder SYSPREP alle Massenspeicher (außer dem Bootlaufwerk) aus dem System zu entfernen. It is also possible to disable additional mass storage devices in BIOS. Panel PC 800 User's Manual V1.30...
  • Page 247: Drivers

    The driver is available in the Downloads section of the B&R website (www.br-automation.com). It is important that both the Enhanced Write Filter (EWF) and the File Based Write Filter (FBWF) are disabled for this. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
  • Page 248: Windows Ce

    Table 207: Windows CE 6.0 features The color depth depends on the display used. The "Compress Windows CE image" function in the B&R Embedded OS Installer can be used to reduce the image size. Panel PC 800 User's Manual V1.30...
  • Page 249: Requirements

    CE installation. The B&R Embedded OS Installer is available in the Downloads section of the B&R website (www.br- automation.com). Additional information is available in the online help documentation for the B&R Embedded OS Installer. Panel PC 800 User's Manual V1.30...
  • Page 250: Automation Runtime

    System support is provided by ARwin with an AS 3.0.90 / AR 3.06 upgrade. An Automation Runtime dongle (USB interface button holder with Automation Runtime ARwin dongle) must be connected to run ARwin on a Panel PC 800, see "Order data" on page 250. Information: An Automation Runtime dongle is no longer required in AS 3.0.90 / AR 4.00.
  • Page 251: R Automation Device Interface (Adi) - Control Center

    • Reading software versions • Updating and backing up BIOS and firmware • Creating reports about the current system (support assistance) • Setting the SDL equalizer value when adjusting SDL cables • Changing the user serial ID Panel PC 800 User's Manual V1.30...
  • Page 252: Installation

    The ADI driver is already included in B&R images of embedded operating systems. If a more current ADI driver version exists (see the Downloads section of the B&R website), it can be installed later. It is important that Enhanced Write Filter (EWF) is disabled for this. Panel PC 800 User's Manual V1.30...
  • Page 253: Sdl Equalizer Settings

    The optimal value for the cable length is defined by selecting "Use automatic setting". The equalizer value can only be changed if the function is supported by Automation Panel 900 (Panel firmware version 1.04 or higher). Panel PC 800 User's Manual V1.30...
  • Page 254: Ups Configuration

    Administrator rights are required in order to change the energy options or display the UPS status. 11.4.2 Displaying UPS default values 1. Open the Control Center in the Control Panel. 2. Select the UPS tab. Panel PC 800 User's Manual V1.30...
  • Page 255: Changing Ups Battery Settings

    1. Open the Control Center in the Control Panel. 2. Select the UPS tab. 3. Under Battery settings, click on Edit. This opens the "Open" dialog box. 4. Select and open the file containing the battery settings. Panel PC 800 User's Manual V1.30...
  • Page 256: Updating Ups Battery Settings

    • The UPS cannot be operated while the battery settings are being updated. • If the transfer is aborted, then the procedure must be repeated until the battery settings have been updated successfully. Otherwise, battery operation will no longer be possible. Panel PC 800 User's Manual V1.30...
  • Page 257: Saving Ups Battery Settings

    • The UPS is automatically restarted after the UPS settings have been changed. This can cause a brief disruption in communication with the UPS. • Administrator rights are required in order to change the energy options or display the UPS status. Panel PC 800 User's Manual V1.30...
  • Page 258: Changing Additional Ups Settings

    1.08 do not shut down automatically when the battery level is low. 11.4.7 Changing additional UPS settings 1. Open the Control Center in the Control Panel. 2. Select the UPS tab. 3. Under UPS settings, click on Advanced. This opens the following window: Panel PC 800 User's Manual V1.30...
  • Page 259 Regardless of these options, all changes to the UPS status are logged in the Windows event log (under "Application"). The Windows Messenger service is supported starting with B&R Windows Embedded version 2.20 and higher. Panel PC 800 User's Manual V1.30...
  • Page 260: Procedure Following Power Failure

    If power returns during the switch-off time, then the shutdown procedure is aborted. If power returns during the shutdown process, then the shutdown timer will run until the B&R Industrial PC enters standby mode, at which point the system will be rebooted. Panel PC 800 User's Manual V1.30...
  • Page 261: R Automation Device Interface (Adi) Development Kit

    • Automation PC 810 • Automation PC 820 • Automation PC 910 • Automation PC 2100 • Panel PC 300 • Panel PC 700 • Panel PC 800 • Panel PC 900 • Panel PC 2100 Panel PC 800 User's Manual V1.30...
  • Page 262 A detailed description of how to use ADI functions can be found in the help system. The B&R Automation Device Interface (ADI) development kit is available at no cost in the Downloads section of the B&R website (www.br-automation.com). Panel PC 800 User's Manual V1.30...
  • Page 263: R Automation Device Interface (Adi) .Net Sdk

    • Automation PC 910 • Automation PC 2100 • Panel PC 300 • Panel PC 700 • Panel PC 800 • Panel PC 900 • Panel PC 2100 • Power Panel 100/200 • Power Panel 300/400 Panel PC 800 User's Manual V1.30...
  • Page 264 B&R images of embedded operating systems. A detailed description of how to use ADI functions can be found in the help system. The ADI .NET SDK is available in the Downloads section of the B&R website (www.br-automation.com). Panel PC 800 User's Manual V1.30...
  • Page 265: R Key Editor

    • Automation PC 510 • Automation PC 511 • Automation PC 620 • Automation PC 810 • Automation PC 820 • Automation PC 910 • Automation PC 2100 • Automation Panel 800 • Automation Panel 830 Panel PC 800 User's Manual V1.30...
  • Page 266 A detailed guide for configuring keys and LEDs can be found in the B&R Key Editor's help system. The B&R Key Editor is available at no cost in the Downloads section of the B&R website (www.br-automation.com). It can also be found on the B&R HMI Drivers & Utilities DVD (model number 5SWHMI.0000-00). Panel PC 800 User's Manual V1.30...
  • Page 267: Chapter 5 Standards And Certifications

    These devices satisfy the requirements of EC directive "2006/95/EC Low voltage directive" and are designed for the following areas: EN 61131-2:2007 Programmable logic controllers - Part 2: Equipment requirements and tests EN 60204-1:2006 + Safety of machinery - Electrical equipment of machines - Part 1: General require- A1:2009 ments Panel PC 800 User's Manual V1.30...
  • Page 268: Certifications

    Canadian (CSA) standard in accordance with C22.2 No. 142-M1987 2.2 GOST-R Produkte mit dieser Kennzeichnung sind von einem akkreditierten Testlabor geprüft und dürfen in die Russische Föderation eingeführt werden (basierend auf der CEKon- formität). Panel PC 800 User's Manual V1.30...
  • Page 269: Chapter 6 Accessories

    Product ID 0AC201.91 4A0006.00-000 General information Storage time Max. 3 years at 30°C Certification cULus Electrical characteristics Capacity 950 mAh Self-discharging <1% per year (at 23°C) Voltage range Table 210: 0AC201.91, 4A0006.00-000 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 270 Accessories • Replacement CMOS batteries Product ID 0AC201.91 4A0006.00-000 Environmental conditions Temperature Storage -20 to 60°C Relative humidity Operation 0 to 95% Storage 0 to 95% Transport 0 to 95% Table 210: 0AC201.91, 4A0006.00-000 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 271: Power Connectors

    Yes, although applies only if all components installed within the complete system have this certification Cage clamp terminal blocks cannot be used side-by-side. The limit data for each I/O module must be taken into consideration. Panel PC 800 User's Manual V1.30...
  • Page 272: Dvi/Monitor Adapter

    This adapter enables a standard monitor to be connected to the DVI-I interface. 3.3 Order data Model number Short description Figure Miscellaneous 5AC900.1000-00 DVI (male connector) to CRT (female connector) adapter. For connecting a standard monitor to a DVI-I interface. Table 213: 5AC900.1000-00 - Order data Panel PC 800 User's Manual V1.30...
  • Page 273: Usb Interface Cover

    Accessories • USB interface cover 4 USB interface cover 4.1 5AC900.1201-00 4.1.1 General information Flat front-side USB interface cover for Automation Panel 900, Power Panel 500, Panel PC 700 and Panel PC 800 devices. 4.1.2 Order data Model number Short description...
  • Page 274: Clamping Blocks

    These replacement clamping blocks are used to mount B&R panel devices. 5.1.2 Order data Model number Short description Figure Accessories 5AC900.BLOC-00 Terminal block with brackets, 10 pcs.; replacement part Table 216: 5AC900.BLOC-00 - Order data Panel PC 800 User's Manual V1.30...
  • Page 275: Uninterruptible Power Supply

    • A suitable system unit • Add-on UPS module 5AC600.UPSI-00 • Battery unit 5AC600.UPSB-00 • UPS connection cable 0.5 m (5CAUPS.0005-00) or 3 m (5CAUPS.0030-00) • Configuration of the B&R UPS in the ADI Control Center Panel PC 800 User's Manual V1.30...
  • Page 276: 5Ac600.Upsi-00

    Yes, although applies only if all components installed within the complete system have this certification 6.3.4 Installation This module is installed using the materials included in delivery. For more information regarding installation, see chapter 7 "Maintenance and service". Panel PC 800 User's Manual V1.30...
  • Page 277 Accessories • Uninterruptible power supply Connection cables Spacer bolt (14 mm) Mounting bracket Spacer bolt (16 mm) UPS insulation Spacer sleeve (2 mm) Torx screws (T10) Figure 145: 5AC600.UPSI-00 Add-on UPS module - Installation materials Panel PC 800 User's Manual V1.30...
  • Page 278: 5Ac600.Upsb-00

    -65 to 80°C Transport -65 to 80°C Relative humidity Operation 5 to 95%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Altitude Operation Max. 3000 m Table 220: 5AC600.UPSB-00, 5AC600.UPSB-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 279: Service Life

    The following diagram shows the relationship between ambient temperature and service life. 50% reduction in service life expectancy when temperature increased by 8°C 33°C Ambient temperature [°C] 6.4.5 Deep discharge cycles 1000000 100000 10000 1000 Discharge depth [%] Figure 146: Deep discharge cycles Panel PC 800 User's Manual V1.30...
  • Page 280: Dimensions

    6.4.7 Drilling template Outline 178.9 170.5 141.9 38.9 126.5 Figure 148: 5PC600.UPSB-00 - Drilling template 6.4.8 Installation instructions Due to the unique construction of these batteries, they can be stored and operated in any position. Panel PC 800 User's Manual V1.30...
  • Page 281: 5Caups.00Xx-00

    Fixed installation 5x wire cross section Weight Approx. 100 g Approx. 470 g Table 222: 5CAUPS.0005-00, 5CAUPS.0030-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
  • Page 282: 5Ac600.Upsf-00

    These 25 A fuses are replacement parts for the 5AC600.UPSB-00 battery unit (beginning with revision E0) as well as the 5AC600.UPSF-00 fuse kit. 6.7.2 Order data Model number Short description Figure Uninterruptible power supplies 5AC600.UPSF-01 UPS fuse, 5 pcs. Table 224: 5AC600.UPSF-01 - Order data Panel PC 800 User's Manual V1.30...
  • Page 283: External Ups

    RS232 null modem cable, 1.8 m, for connecting UPS and IPC (9-pin female DSUB connector - 9-pin female DSUB connector) Optional accessories Replacement batteries Table 225: 9A0100.11, 9A0100.12, 9A0100.13, 9A0100.14, 9A0100.15, 9A0100.16, 9A0100.17 - Order data Panel PC 800 User's Manual V1.30...
  • Page 284 UPS batteries type B (replacement part), 2x 12 V, 2.2 Ah, for battery unit 9A0100.14 9A0100.17 UPS batteries type C (replacement part), 2x 12 V, 4.5 Ah, for battery unit 9A0100.16 Table 225: 9A0100.11, 9A0100.12, 9A0100.13, 9A0100.14, 9A0100.15, 9A0100.16, 9A0100.17 - Order data Panel PC 800 User's Manual V1.30...
  • Page 285: Pci Plug-In Cards

    8.1.3 Technical data Product ID 5ACPCI.ETH1-01 General information B&R ID code 0xA58A Diagnostics Data transfer Yes, using status LED Certification cULus cULus HazLoc Class 1 Division 2 GOST-R Table 227: 5ACPCI.ETH1-01 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 286: Driver Support

    (Windows XP Professional, Windows XP Embedded and MS-DOS) are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
  • Page 287: Dimensions

    Accessories • PCI plug-in cards 8.1.5 Dimensions 42.6 106.3 121.7 Figure 151: 5ACPCI.ETH1-01 - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 288: 5Acpci.eth3-01

    8.2.3 Technical data Product ID 5ACPCI.ETH3-01 General information B&R ID code 0xA58B Diagnostics Data transfer Yes, using status LED Certification cULus cULus HazLoc Class 1 Division 2 GOST-R Table 230: 5ACPCI.ETH3-01 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 289: Driver Support

    (Windows XP Professional, Windows XP Embedded and MS-DOS) are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
  • Page 290: Dimensions

    Accessories • PCI plug-in cards 8.2.5 Dimensions 42.6 106.3 121.7 Figure 153: 5ACPCI.ETH3-01 - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 291: Compactflash Cards

    Self-Monitoring, Analysis and Reporting Technology (S.M.A.R.T.) is an industry standard for mass storage devices that has been introduced to monitor important parameters and quickly detect imminent failures. Critical performance and calibration data is monitored and stored in order to help predict the probability of errors. Panel PC 800 User's Manual V1.30...
  • Page 292: Maximum Reliability

    Accessories • CompactFlash cards 9.2.5 Maximum reliability CompactFlash cards used by B&R use SLC flash blocks and static wear leveling together with a powerful ECC algorithm to provide maximum reliability. Panel PC 800 User's Manual V1.30...
  • Page 293: 5Cfcrd.xxxx-06

    CompactFlash 8 GB B&R (SLC) ≤ Rev. E0 5CFCRD.016G-06 CompactFlash 16 GB B&R (SLC) ≤ Rev. D0 5CFCRD.032G-06 CompactFlash 32 GB B&R (SLC) ≤ Rev. C0 Table 233: 5CFCRD.0512-06, 5CFCRD.1024-06, 5CFCRD.2048-06, 5CFCRD.4096-06, 5CFCRD.8192-06, 5CFCRD.016G-06, 5CFCRD.032G-06 - Order data Panel PC 800 User's Manual V1.30...
  • Page 294: Technical Data

    Setup ≥ ≥ V3.0.2.3014) V2.06.00.3011) V2.06.00.3011) V2.06.00.3011) V2.06.00.3011) V2.06.00.3011) V3.0.0.3020) B&R Embedded OS Installer ≥V3.10 ≥V3.10 ≥V3.10 ≥V3.10 ≥V3.10 ≥V3.20 ≥V3.21 Table 234: 5CFCRD.0512-06, 5CFCRD.1024-06, 5CFCRD.2048-06, 5CFCRD.4096-06, 5CFCRD.8192-06, 5CFCRD.016G-06, 5CFCRD.032G-06 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 295 14 MB/s 14 MB/s 28 MB/s 28 MB/s Maximum 18 MB/s 18 MB/s 18 MB/s 17 MB/s 17 MB/s 30 MB/s 30 MB/s Table 235: 5CFCRD.0512-06, 5CFCRD.1024-06, 5CFCRD.2048-06, 5CFCRD.4096-06, 5CFCRD.8192-06, 5CFCRD.016G-06, 5CFCRD.032G-06 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 296 Yes, although applies only if all components installed within the complete system have this certification Endurance of B&R CFs (with linear written block size ≥128 kB). Not supported by the B&R Embedded OS Installer. Panel PC 800 User's Manual V1.30...
  • Page 297: Temperature/Humidity Diagram

    Figure 154: 5CFCRD.xxxx-06 - Temperature/Humidity diagram for CompactFlash cards 9.3.5 Dimensions 1.01 ±0.07 1.01 ±0.07 3.30 ±0.1 CompactFlash Type I 2.44 ±0.07 Above 1.65 0.63 ±0.07 41.66 ±0.13 4x R0.5 ±0.1 42.8 ±0.1 Figure 155: Type I CompactFlash card - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 298: Benchmark

    Accessories • CompactFlash cards 9.3.6 Benchmark Transfer size [kB] Figure 156: ATTO Disk Benchmark v2.34 read comparison - 5CFCRD.xxxx-04 and 5CFCRD.xxxx-06 Transfer size [kB] Figure 157: ATTO Disk Benchmark v2.34 write comparison - 5CFCRD.xxxx-04 and 5CFCRD.xxxx-06 Panel PC 800 User's Manual V1.30...
  • Page 299: 5Cfcrd.xxxx-04

    (240X) (220X) (180X) (240X) Maximum 37 MB/s 37 MB/s 37 MB/s 34 MB/s 28 MB/s 37 MB/s (260X) (260X) (260X) (226X) (186X) (247X) Table 237: 5CFCRD.0512-04, 5CFCRD.1024-04, 5CFCRD.2048-04, 5CFCRD.4096-04, 5CFCRD.8192-04, 5CFCRD.016G-04 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 300 Speed specification with 1X = 150 Kb/s. All specifications refer to Samsung flash chips, CompactFlash cards in UDMA mode 4 and 30 ns cycle time in True IDE mode with sequential write/read test. Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
  • Page 301: Temperature/Humidity Diagram

    Figure 158: 5CFCRD.xxxx-04 - Temperature/Humidity diagram for CompactFlash cards 9.4.5 Dimensions 1.01 ±0.07 1.01 ±0.07 3.30 ±0.1 CompactFlash Type I 2.44 ±0.07 Above 1.65 0.63 ±0.07 41.66 ±0.13 4x R0.5 ±0.1 42.8 ±0.1 Figure 159: Type I CompactFlash card - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 302: Benchmark

    Accessories • CompactFlash cards 9.4.6 Benchmark Transfer size [kB] Figure 160: ATTO Disk Benchmark v2.34 read comparison - 5CFCRD.xxxx-03 and 5CFCRD.xxxx-04 Transfer size [kB] Figure 161: ATTO Disk Benchmark v2.34 write comparison - 5CFCRD.xxxx-03 and 5CFCRD.xxxx-04 Panel PC 800 User's Manual V1.30...
  • Page 303: 5Cfcrd.xxxx-03

    2 GB 4 GB 8 GB Data retention 10 years Data reliability <1 unrecoverable error in 10 bit read accesses Lifetime monitoring Table 239: 5CFCRD.0064-03, 5CFCRD.0128-03, 5CFCRD.0256-03, 5CFCRD.0512-03, 5CFCRD.1024-03, 5CFCRD.2048-03, 5CFCRD.4096-03, 5CFCRD.8192-03 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 304 Table 239: 5CFCRD.0064-03, 5CFCRD.0128-03, 5CFCRD.0256-03, 5CFCRD.0512-03, 5CFCRD.1024-03, 5CFCRD.2048-03, 5CFCRD.4096-03, 5CFCRD.8192-03 - Technical data Yes, although applies only if all components installed within the complete system have this certification Not supported by the B&R Embedded OS Installer. Panel PC 800 User's Manual V1.30...
  • Page 305: Temperature/Humidity Diagram

    Figure 162: 5CFCRD.xxxx-03 - Temperature/Humidity diagram for CompactFlash cards 9.5.5 Dimensions 1.01 ±0.07 1.01 ±0.07 3.30 ±0.1 CompactFlash Type I 2.44 ±0.07 Above 1.65 0.63 ±0.07 41.66 ±0.13 4x R0.5 ±0.1 42.8 ±0.1 Figure 163: Type I CompactFlash card - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 306: Known Problems/Issues

    The problem described can occur because the startup time for the CompactFlash cards fluctuates due to the different components being used. Depending on the CompactFlash card being used, this error might never, sometimes or always occur. Panel PC 800 User's Manual V1.30...
  • Page 307: Usb Flash Drives

    Operating systems Windows XP Professional Windows XP Embedded Windows ME Windows 2000 Windows CE 5.0 Windows CE 4.2 Electrical characteristics Power consumption 650 µA sleep mode, 150 mA read/write Table 241: 5MMUSB.2048-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 308: Temperature/Humidity Diagram

    Width 19 mm Length 52.2 mm Height 7.9 mm Table 241: 5MMUSB.2048-00 - Technical data Indicates data being transferred (sending and receiving). 10.1.4 Temperature/Humidity diagram Operation Temperature [°C] Figure 164: 5MMUSB.2048-00 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 309: 5Mmusb.xxxx-01

    Windows XP Professional Windows XP Embedded Windows ME Windows 2000 Windows CE 5.0 Windows CE 4.2 Electrical characteristics Power consumption Max. 500 µA sleep mode, max. 120 mA read/write Table 243: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 310: Temperature/Humidity Diagram

    Length 67.85 mm Height 8.35 mm Table 243: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data Indicates data being transferred (sending and receiving). 10.2.4 Temperature/Humidity diagram Storage Operation Transport Temperature [°C] Figure 165: 5MMUSB.xxxx-01 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
  • Page 311: Usb Media Drive

    USB A interface slot Figure 166: 5MD900.USB2-02 - Interfaces 11.1.4 Technical data Product ID 5MD900.USB2-02 General information Max. cable length 5 m (not including hub) Certification cULus GOST-R Table 245: 5MD900.USB2-02 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 312 10 to 100 Hz: 2 g (19.6 m/s² 0-peak) Transport 10 to 100 Hz: 2 g (19.6 m/s² 0-peak) Shock Operation 5 g, 11 ms Storage 60 g, 11 ms Transport 60 g, 11 ms Table 245: 5MD900.USB2-02 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 313: Dimensions

    Temperature specifications refer to operation at 500 meters. The maximum ambient temperature is typically derated by 1°C per 1000 meters (starting at 500 meters above sea level). 11.1.5 Dimensions Figure 167: 5MD900.USB2-02 - Dimensions 11.1.6 Dimensions with front cover Figure 168: USB media drive with front cover - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 314: Cutout Installation

    The USB media drive can be operated as a desktop device (rubber feet) or as a rack-mounted device (2 mounting rail brackets included). 11.1.9.1 Mounting orientation Less than 20° Less than 20° Less than 20° Less than 20° Figure 170: 5MD900.USB2-02 - Mounting orientation Panel PC 800 User's Manual V1.30...
  • Page 315: 5A5003.03

    Table 248: 5A5003.03 - Technical data 11.2.4 Dimensions Figure 171: 5A5003.03 - Dimensions 11.2.5 Contents of delivery Quantity Component Front cover 5A5003.03 for the USB media drive M3 locknut Cover retaining clip Table 249: 5A5003.03 - Contents of delivery Panel PC 800 User's Manual V1.30...
  • Page 316: Installation

    11.2.6.1 Cutout installation Outer contour (front cover) Outer contour (media device) 67.5 Cutout Cutout size 183 ±0.5 mm x 55 ±0.5 mm 12.5 189.5 Figure 173: USB media drive with front cover - Installation cutout Panel PC 800 User's Manual V1.30...
  • Page 317: Hmi Drivers & Utilities Dvd

    • Automation PC 620 / Panel PC 700 CPU board 945GME N270 BIOS • Automation PC 680 • Automation PC 810 / Automation PC 820 / Panel PC 800 B945GME BIOS • Automation PC 810 / Panel PC 800 945GME N270 CPU board BIOS •...
  • Page 318 • Power Panel 300/400 (aPCI) • Power Panel 300/400 (MTCX) • Power Panel 500 / Automation PC 510 / Automation PC 511 (MTCX, SDLR, I/O board) • Panel PC 800 (MTCX, SDLR, SDLT) • UPS firmware Utilities/Tools • B&R Embedded OS Installer •...
  • Page 319 • Acrobat Reader 5.0.5 (freeware in German, English and French) • Power Archiver 6.0 (freeware in German, English and French) • Internet Explorer 5.0 (German and English) • Internet Explorer 6.0 (German and English) Panel PC 800 User's Manual V1.30...
  • Page 320: Cables

    ≥5x cable diameter (male connector - ferrite bead and ferrite bead - ferrite bead) Weight Approx. 260 g Approx. 460 g Approx. 790 g Table 252: 5CADVI.0018-00, 5CADVI.0050-00, 5CADVI.0100-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
  • Page 321 Male connector Flex radius Flex radius Male connector - Ferrite bead Ferrite bead - Ferrite bead Ferrite bead Ferrite bead Figure 174: Flex radius specifications 13.1.1.5 Dimensions 25±5 28.5 Length Figure 175: 5CADVI.0xxx-00 - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 322 If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. DVI-D (24+1), male DVI-D (24+1), male Pinout DVI-D (24+1), male DVI-D (24+1), male Cable shield Cable shield Figure 176: 5CADVI.0xxx-00 - Pinout Panel PC 800 User's Manual V1.30...
  • Page 323: Sdl Cable

    Approx. 1500 g Approx. 2250 g Approx. 2880 g Approx. 4800 g Approx. 5520 g Table 254: 5CASDL.0018-00, 5CASDL.0050-00, 5CASDL.0100-00, 5CASDL.0150-00, 5CASDL.0200-00, 5CASDL.0250-00, 5CASDL.0300-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
  • Page 324 Male connector Flex radius Flex radius Male connector - Ferrite bead Ferrite bead - Ferrite bead Ferrite bead Ferrite bead Figure 177: Flex radius specifications 13.2.1.5 Dimensions 35±5 28.5 Length Figure 178: 5CASDL.0xxx-00 - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 325 If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 179: 5CASDL.0xxx-00 - Pinout Panel PC 800 User's Manual V1.30...
  • Page 326: Sdl Cable With 45° Male Connector

    Approx. 300 g Approx. 590 g Approx. 2800 g Approx. 2860 g Table 256: 5CASDL.0018-01, 5CASDL.0050-01, 5CASDL.0100-01, 5CASDL.0150-01 - Technical data Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
  • Page 327 Male connector Flex radius Flex radius Male connector - Ferrite bead Ferrite bead - Ferrite bead Ferrite bead Ferrite bead Figure 180: Flex radius specifications 13.3.1.5 Dimensions 35±5 28.5 Length Figure 181: 5CASDL.0xxx-01 - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 328 If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 182: 5CASDL.0xxx-01 - Pinout Panel PC 800 User's Manual V1.30...
  • Page 329: Sdl Flex Cables

    UL AWM 20236 80°C 30 V Flame-resistant In accordance with UL758 (cable vertical flame test) Oil and hydrolysis resistance In accordance with VDE 0282-10 Table 258: 5CASDL.0018-03, 5CASDL.0050-03, 5CASDL.0100-03, 5CASDL.0150-03, 5CASDL.0200-03, 5CASDL.0250-03, 5CASDL.0300-03 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 330 Flex radius Flex radius Male connector - Ferrite bead Ferrite bead - Ferrite bead Ferrite bead Ferrite bead Figure 183: Flex radius specifications 13.4.1.5 Dimensions 36.5 37.5 ±2.5 ±10 Length Figure 184: 5CASDL.0xxx-03 - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 331 DDC data SDL+ SDL+ SDL- SDL- TMDS data 2/SDL shielding TMDS data 2/SDL shielding TMDS data 2+ TMDS data 2+ TMDS data 2- TMDS data 2- Cable shield Cable shield Figure 185: 5CASDL.0xxx-03 - Pinout Panel PC 800 User's Manual V1.30...
  • Page 332: Sdl Flex Cable With Extender

    Oil and hydrolysis resistance In accordance with VDE 0282-10 Environmental conditions Temperature Storage -20 to 60°C Fixed installation -20 to 60°C Flexible installation -5 to 60°C Table 261: 5CASDL.0300-13, 5CASDL.0400-13, 5CASDL.0430-13 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 333 Flex radius Flex radius Male connector - Ferrite bead Ferrite bead - Extender Ferrite bead Extender Figure 186: Flex radius specification with extender 13.5.1.5 Dimensions 36.5 ±10 37.5 ±2.5 Length Figure 187: 5CASDL.0xx0-13 - Dimensions Panel PC 800 User's Manual V1.30...
  • Page 334 If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 188: 5CASDL.0xx0-13 - Pinout Panel PC 800 User's Manual V1.30...
  • Page 335 SDL flex cables with an extender must be connected between the B&R Industrial PC and the Automation Panel display unit in the correct direction. The proper signal direction is indicated on the extender. B&R Industrial PC Figure 189: Example of the signal direction for an SDL flex cable with extender Panel PC 800 User's Manual V1.30...
  • Page 336: Usb Cables

    If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. Pinout USB Type A, male USB Type B, male Jacket Jacket Figure 190: 5CAUSB.00xx-00 USB cables - Pinout Panel PC 800 User's Manual V1.30...
  • Page 337: 9A0014.Xx

    Max. 0.5 Nm Mechanical characteristics Dimensions Length 1.8 m ±50 mm 5 m ±80 mm 10 m ±100 mm Diameter Max. 5 mm Flex radius Min. 70 mm Table 265: 9A0014.02, 9A0014.05, 9A0014.10 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 338 If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. 9-pin male DSUB 9-pin female DSUB Pinout 9-pin male DSUB 9-pin female DSUB Jacket Jacket Figure 191: 9A0014.xx RS232 cables - Pinout Panel PC 800 User's Manual V1.30...
  • Page 339: Internal Supply Cable

    Wire cross section AWG 22 Connector Type 1x 4-pin male disk drive power connector, 1x 4-pin female connector housing Mechanical characteristics Dimensions Length 100 mm ±5 mm Flexibility Flexible Table 267: 5CAMSC.0001-00 - Technical data Panel PC 800 User's Manual V1.30...
  • Page 340: Chapter 7 Maintenance And Service

    • Touch the housing or ground connection in order to discharge any electrostatic charge from your body. • Remove the cover from the battery compartment and carefully pull out the battery using the removal strip. Panel PC 800 User's Manual V1.30...
  • Page 341 • Reconnect the power supply to the B&R Industrial PC (plug in the power cable). • Reset the date and time in BIOS. Warning! Lithium batteries are considered hazardous waste. Used batteries should be disposed of in accordance with applicable local regulations. Panel PC 800 User's Manual V1.30...
  • Page 342: Cleaning

    (ethanol). The cleaning agent should be applied to the cloth beforehand, not sprayed directly on the device! Aggressive solvents, chemicals, scouring agents, pressurized air or steam jets should never be used. Information: Displays with a touch screen should be cleaned regularly. Panel PC 800 User's Manual V1.30...
  • Page 343: Replacing A Compactflash Card

    Power must be turned off before replacing CompactFlash cards. The CompactFlash card can be replaced quickly and easily by pressing the ejector (see image) with a pointed object such as a pen. Ejector CompactFlash Figure 195: CompactFlash + ejector Panel PC 800 User's Manual V1.30...
  • Page 344: Installing And Replacing Slide-In Compact Drives

    1. Loosen and remove the two quick release screws on the protective cover / slide-in compact drive. Figure 196: Loosening the quick release screws 2. Insert the compact SATA drive and tighten the quick release screws. Figure 197: Inserting the compact SATA drive Panel PC 800 User's Manual V1.30...
  • Page 345: Installing And Replacing Slide-In Drives

    3. Remove the dummy slide-in module or slide-in drive by unscrewing the two quick release screws. Figure 198: Loosening the quick release screws 4. Insert the slide-in drive and tighten with the two ¼ turn screws. Figure 199: Installing the slide-in drive Panel PC 800 User's Manual V1.30...
  • Page 346: Installing The Slide-In Compact Adapter

    4. Insert the slide-in compact adapter and tighten the two quick release screws. Figure 201: Installing the slide-in compact adapter 5. Once the adapter has been installed, the slide-in compact drive can be inserted. Panel PC 800 User's Manual V1.30...
  • Page 347 Maintenance and service • Installing the slide-in compact adapter Figure 202: Inserting the slide-in compact drive Panel PC 800 User's Manual V1.30...
  • Page 348: Installing And Replacing Fan Kits

    Fan kit cover Filter clasp Dust filter Figure 205: Securing the dust filter with the filter clasp 4. Place the fan kit cover in the housing and fasten using the Torx screws removed earlier. Panel PC 800 User's Manual V1.30...
  • Page 349 Maintenance and service • Installing and replacing fan kits Information: The dust filter should be checked regularly depending on the area of use and degree of contamination. Panel PC 800 User's Manual V1.30...
  • Page 350: Installing The Ups Module

    3. Attach the UPS isolation to the bottom/rear of the UPS module and install both using 2 Torx screws (T10) on the housing and 1 Torx screw (T10) on the mainboard (spacer bolt). Use the previously removed Torx screws and the Torx screws from the installation material. Figure 208: Installing the UPS module Panel PC 800 User's Manual V1.30...
  • Page 351 4. Attach the connection cable (see marked female connector). Figure 209: Attaching the connection cable Information: When connecting the cable, make sure that the connector locks into place. Figure 210: Connector locking mechanism 5. Attach the side cover. Panel PC 800 User's Manual V1.30...
  • Page 352: Installing The Ups Fuse Kit On The Battery Unit

    Figure 211: Removing the cover for the battery unit 3. To install the fuse, the red cable must be disconnected from the battery circuit board. Figure 212: Disconnecting the cable Panel PC 800 User's Manual V1.30...
  • Page 353 6. The cover for the battery unit can now be reattached. Insert the clips on the cover into the notch on the battery unit and tighten down the cover with the Torx screws removed previously. 7. Reconnect the 5AC600.UPSB-00 battery unit to the B&R Industrial PC. Panel PC 800 User's Manual V1.30...
  • Page 354: Installing And Replacing Bus Units

    Bus units can be installed and replaced in system units with 1 card slot or in expansions with 2 card slots. 10.1 Procedure 1. Disconnect the power supply to the Panel PC 800. 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body.
  • Page 355: Installing And Replacing Adapters

    Figure 217: Removing the screws 2. Place the adapter and guide rails in the intended positions and fasten them using the Torx screws (T10) removed earlier. Figure 218: Installing the 5AC803.BC01-00 adapter 3. Attach the side cover. Panel PC 800 User's Manual V1.30...
  • Page 356: Procedure For The 5Ac803.Bc02-00 Adapter

    Maintenance and service • Installing and replacing adapters 11.2 Procedure for the 5AC803.BC02-00 adapter 1. Insert the adapter into the intended slot. Figure 219: Installing the 5AC803.BC02-00 adapter 2. Attach the side cover. Panel PC 800 User's Manual V1.30...
  • Page 357: Installing And Replacing Pciec Plug-In Cards

    1. Loosen the quick release screws and remove the PCIec module cover. Figure 220: Removing the PCIec module cover 2. Slide the PCIec plug-in card into place. Figure 221: Inserting the PCIec plug-in card 3. Fasten the PCIec plug-in card using the quick release screws. Panel PC 800 User's Manual V1.30...
  • Page 358: Installing The Side Cover

    13.1 PPC800 without expansion 1. Disconnect the power supply to the Panel PC 800. 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body. 3. Loosen the indicated combi-Torx screws (T10).
  • Page 359: Replacing A Pci Sata Raid Hard Disk In A Raid 1 Set

    6. On the front side, slide the hard disk down and away (Replacing the hard disk - left image). 7. Insert the new hard disk carefully into the connector (Replacing the hard disk - right image), being careful to only touch it on the front, not on the top. Panel PC 800 User's Manual V1.30...
  • Page 360 10.An error message is output by the RAID BIOS after starting the system: "RAID1 set is in Rebuild status. The rebuild will continue after boot sequence is complete". 11. A rebuild can be performed immediately in SATA RAID BIOS or once the PC has booted - see "Rebuild mirrored set" on page 179. Panel PC 800 User's Manual V1.30...
  • Page 361: Maintenance Controller Extended (Mtcx)

    The MTCX constantly monitors the temperature using temperature sensors, which directly determines how the fans are controlled. The speed depends on the measured temperature. The limit values depend on the MTCX firmware version being used. Available in the Downloads section of the B&R website (www.br-automation.com). Panel PC 800 User's Manual V1.30...
  • Page 362 For example, slide-in 1: 44°C + 16°C = 60°C --> Maximum fan speed The fans will only be shut off again if the evaluation temperature is more than 6°C below the switch-on temperature for a period of 30 minutes (=overshoot time). Panel PC 800 User's Manual V1.30...
  • Page 363: Connecting An External Device To The Mainboard

    Connector for external devices Assignment Power 4-pin connector, male +12 VDC Max. 10 watts Max. 5 watts +5 VDC Table 271: Connector on the mainboard - Pinout Connections are protected with a 1 A multi-fuse. Panel PC 800 User's Manual V1.30...
  • Page 364: 5-Wire Amt Touch Screen

    Figure 228: 5-wire AMT touch screen - Temperature/Humidity diagram 3.3 Cleaning Danger! This device can only be cleaned when switched off in order to prevent unintended functions from being triggered when handling the touch screen or pressing keys. Panel PC 800 User's Manual V1.30...
  • Page 365 (ethanol). The cleaning agent should be applied to the cloth beforehand, not sprayed directly on the device! Aggressive solvents, chemicals, scouring agents, pressurized air or steam jets should never be used. Information: Displays with a touch screen should be cleaned regularly. Panel PC 800 User's Manual V1.30...
  • Page 366: Panel Overlay

    Sea water Decon Table 273: Chemical resistance of the panel overlay The panel overlay conforms to DIN 42115 section 2 for exposure to glacial acetic acid for less than one hour without visible damage. Panel PC 800 User's Manual V1.30...
  • Page 367: Viewing Angles

    Appendix A • Viewing angles 5 Viewing angles Viewing angle specifications (R, L, U, D) for the display types are listed in the technical data for each device. Facing 6 o'clock Panel PC 800 User's Manual V1.30...
  • Page 368: Mounting Compatibility

    6 Mounting compatibility This section describes the compatibility of the installation dimensions for Power Panel 100/200, Power Panel 300/400, Power Panel 500, Automation Panel 900, Automation Panel 700 and Panel PC 800 devices according to device display size. The outer dimensions of the device types are identical for the respective display sizes.
  • Page 369: Compatibility Details

    Outer contour of device Cutout for device Figure 230: Mounting compatibility - 5.7" device - Horizontal1 5.7" Power Panel 500 devices and Power Panel 100/200/300/400 devices are 100% mounting compatible in the Horizontal1 format. Panel PC 800 User's Manual V1.30...
  • Page 370 • When mounting, make sure that the PP100/200/300/400 devices are placed and mounted as close to the center of the cutout as possible. Failure to do so can prevent the retaining clips from holding firmly, which means that a firm seal is no longer guaranteed with the gasket (IP65). Panel PC 800 User's Manual V1.30...
  • Page 371: Devices

    • When mounting, make sure that the PP100/200/300/400 devices are placed and mounted as close to the center of the cutout as possible. Failure to do so can prevent the retaining clips from holding firmly, which means that a firm seal is no longer guaranteed with the gasket (IP65). Panel PC 800 User's Manual V1.30...
  • Page 372: Devices

    PP100/200/300/400 AP900/PPC700 345 x 267 0.5 ± 342 x 267 0.5 ± PP500 Outer contour of device Cutout for PP100/200/300/400 device Cutout for AP900/PPC700/PP500 device Figure 236: Mounting compatibility - 12.1" device - Horizontal1 Panel PC 800 User's Manual V1.30...
  • Page 373: 15" Devices

    15" Power Panel 500 devices are not 100% mounting compatible with Power Panel 100/200/300/400, Automation Panel 900, Panel PC 700 and Panel PC 800 devices in the Vertical1 format. The Power Panel 500 devices require a cutout that is 0.5 mm higher (top and bottom edge).
  • Page 374: 17" Devices

    Outer contour of device Cutout for device Figure 240: Mounting compatibility - 19" device - Horizontal1 19" Automation Panel 900, Panel PC 700 and Panel PC 800 are 100% mounting compatible in the Horizontal1 format. Panel PC 800 User's Manual V1.30...
  • Page 375: Devices

    Appendix A • Mounting compatibility 6.2.8 21.3" devices 583 x 464 566 x 447 ±0.5 AP900 Outer contour of device Cutout for device Figure 241: Mounting compatibility - 21.1" device - Horizontal1 Panel PC 800 User's Manual V1.30...
  • Page 376: Glossary

    The cause of the failure may be load related or age-related, and therefore a random failure, or related to a flaw inherent in the system. In this case, it is known as a systematic failure. Panel PC 800 User's Manual V1.30...
  • Page 377 Figure 53: 5AC801.DVRS-00 - Temperature humidity diagram............128 Figure 54: PCI SATA RAID controller....................129 Figure 55: 5ACPCI.RAIC-03 - Temperature humidity diagram.............131 Figure 56: 5ACPCI.RAIC-04 - Temperature humidity diagram.............133 Figure 57: PCI SATA RAID controller....................134 Panel PC 800 User's Manual V1.30...
  • Page 378 Figure 110: 945GME Secondary IDE Slave................... 203 Figure 111: 945GME Advanced USB Configuration................204 Figure 112: 945GME Advanced Keyboard/Mouse Configuration............205 Figure 113: 945GME Advanced Remote Access Configuration.............206 Figure 114: 945GME Advanced CPU Board Monitor................207 Panel PC 800 User's Manual V1.30...
  • Page 379 5MMUSB.xxxx-01 - Temperature/Humidity diagram............310 Figure 167: 5MD900.USB2-02 - Interfaces.....................311 Figure 168: 5MD900.USB2-02 - Dimensions..................313 Figure 169: USB media drive with front cover - Dimensions..............313 Figure 170: USB media drive with front cover - Installation cutout............314 Panel PC 800 User's Manual V1.30...
  • Page 380 Installing the side cover on a PPC800 with an expansion (1-slot expansion shown in image) 358 Figure 225: Screw layout on the back side of the 5ACPCI.RAIC-03 SATA RAID controller....359 Figure 226: Replacing the hard disk.......................360 Figure 227: MTCX controller location..................... 361 Panel PC 800 User's Manual V1.30...
  • Page 381 Mounting compatibility - 15" device - Vertical1..............373 Figure 240: Mounting compatibility - 17" device - Horizontal1............... 374 Figure 241: Mounting compatibility - 19" device - Horizontal1............... 374 Figure 242: Mounting compatibility - 21.1" device - Horizontal1............375 Panel PC 800 User's Manual V1.30...
  • Page 382 Table 50: 5AC803.BC01-00 - Order data....................77 Table 51: 5AC803.BC02-00 - Order data....................77 Table 52: 5ACPCC.ETH0-00 - Order data....................79 Table 53: 5ACPCC.ETH0-00 - Technical data................... 79 Table 54: 5ACPCC.ETH0-00 - Ethernet interface..................80 Panel PC 800 User's Manual V1.30...
  • Page 383 5ACPCI.RAIC-05 - Order data....................134 Table 107: 5ACPCI.RAIC-05 - Technical data....................135 Table 108: 5ACPCI.RAIC-06 - Order data....................137 Table 109: 5ACPCI.RAIC-06 - Technical data....................138 Table 110: 5MMHDD.0250-00 - Order data....................140 Table 111: 5MMHDD.0250-00 - Technical data..................140 Panel PC 800 User's Manual V1.30...
  • Page 384 945GME Advanced - Legacy devices - Configuration options..........211 Table 166: 945GME Boot menu - Configuration options................212 Table 167: 945GME Security menu - Configuration options..............213 Table 168: 945GME Security - Hard disk security user password............. 214 Panel PC 800 User's Manual V1.30...
  • Page 385 5AC900.1201-00 - Order data....................273 Table 215: 5AC900.1201-01 - Order data....................273 Table 216: 5AC900.BLOC-00 - Order data....................274 Table 217: 5AC600.UPSI-00 - Order data....................276 Table 218: 5AC600.UPSI-00 - Technical data....................276 Table 219: 5AC600.UPSB-00 - Order data....................278 Panel PC 800 User's Manual V1.30...
  • Page 386 Table 261: 5CASDL.0300-13, 5CASDL.0400-13, 5CASDL.0430-13 - Technical data....... 332 Table 262: 5CAUSB.0018-00, 5CAUSB.0050-00 - Order data..............336 Table 263: 5CAUSB.0018-00, 5CAUSB.0050-00 - Technical data............336 Table 264: 9A0014.02, 9A0014.05, 9A0014.10 - Order data..............337 Panel PC 800 User's Manual V1.30...
  • Page 387 Connector on the mainboard - Pinout..................363 Table 272: 5-wire AMT touch screen - Technical data................364 Table 273: Chemical resistance of the panel overlay.................366 Table 274: Product abbreviations........................368 Table 275: Overview of device compatibility....................368 Panel PC 800 User's Manual V1.30...
  • Page 388 5AC900.1000-00..............................272 5AC900.1201-00..............................273 5AC900.1201-01..............................273 5AC900.BLOC-00..............................274 5ACPCC.ETH0-00..............................79 5ACPCC.MPL0-00..............................81 5ACPCI.ETH1-01..............................285 5ACPCI.ETH3-01..............................288 5ACPCI.RAIC-03..............................129 5ACPCI.RAIC-04..............................132 5ACPCI.RAIC-05..............................134 5ACPCI.RAIC-06..............................137 5CADVI.0018-00..............................320 5CADVI.0050-00..............................320 5CADVI.0100-00..............................320 5CAMSC.0001-00..............................339 5CASDL.0018-00..............................323 5CASDL.0018-01..............................326 5CASDL.0018-03..............................329 5CASDL.0050-00..............................323 Panel PC 800 User's Manual V1.30...
  • Page 389 5MMDDR.1024-01..............................69 5MMDDR.2048-01..............................69 5MMHDD.0250-00............................... 140 5MMHDD.0500-00............................... 142 5MMSSD.0060-00..............................109 5MMSSD.0060-01..............................111 5MMSSD.0128-01..............................114 5MMSSD.0180-00..............................117 5MMSSD.0256-00..............................119 5MMUSB.2048-00..............................307 5MMUSB.2048-01..............................309 5MMUSB.4096-01..............................309 5PC800.B945-00..............................65 5PC800.B945-01..............................65 5PC800.B945-02..............................65 5PC800.B945-03..............................65 5PC800.B945-04..............................65 5PC800.B945-05..............................65 Panel PC 800 User's Manual V1.30...
  • Page 390 5SWWXP.0500-MUL............................236 5SWWXP.0600-ENG............................236 5SWWXP.0600-GER............................236 5SWWXP.0600-MUL............................236 5SWWXP.0727-ENG............................243 9A0003.02U................................250 9A0014.02................................337 9A0014.05................................337 9A0014.10................................337 9A0100.11................................283 9A0100.12................................283 9A0100.13................................283 9A0100.14................................283 9A0100.15................................283 9A0100.16................................283 9A0100.17................................283 9S0000.01-010..............................235 9S0000.01-020..............................235 Panel PC 800 User's Manual V1.30...
  • Page 391 Cables................................. 320 DVI.................................. 320 SDL................................. 323 SDL flex................................329 SDL flex cable with extender......................... 332 SDL with 45° male connector........................326 USB................................336 Card slot................................52 CE mark................................267 Certifications............................... 268 certifications GOST-R................................268 Certifications Panel PC 800 User's Manual V1.30...
  • Page 392 Electromagnetic compatibility..........................267 Embedded OS Installer............................234 EMC directive..............................267 ESD..................................16 Electrical components with a housing......................16 Electrical components without a housing......................16 Individual components............................16 Packaging................................. 16 Proper handling..............................16 ETH1..................................45 Ethernet................................. 45 Panel PC 800 User's Manual V1.30...
  • Page 393 Installing and replacing slide-in drives....................... 345 Installing the side cover............................. 358 Installing the slide-in compact adapter....................... 346 Installing the UPS fuse kit..........................352 Installing the UPS module..........................350 Interfaces................................41 Interrupt assignment............................224 Key Editor................................265 Panel PC 800 User's Manual V1.30...
  • Page 394 System failure error codes..........................83 power supply..............................41, 156 PPC800 15" Cutout................................58 Dimensions............................... 58 Interfaces................................55 Power calculation............................. 34 Technical data..............................55 PPC800 19" Cutout................................64 Dimensions............................... 64 Interfaces................................61 Power calculation............................. 35 Panel PC 800 User's Manual V1.30...
  • Page 395 Temperature monitoring - Fan control....................... 361 Temperature sensor positions..........................31 Temperature specifications........................... 28 temperature testing............................. 157 Temperature testing instructions........................157 Temperature testing procedure.......................... 157 Touch screen calibration............................. 172 UL certification..............................268 Uninterruptible power supply..........................275 Panel PC 800 User's Manual V1.30...
  • Page 396 Viewing angles..............................367 WES2009................................243 WES7.................................. 246 Windows 7................................238 Windows CE............................... 248 Windows CE 6.0 features..........................248 Windows Embedded Standard 2009........................243 Windows Embedded Standard 7........................245 Windows XP Embedded............................. 241 Windows XP Professional..........................236 Panel PC 800 User's Manual V1.30...

Table of Contents