Panel pc 700 with 945gme n270 cpu board (524 pages)
Summary of Contents for B&R Panel PC 800
Page 1
Panel PC 800 User's Manual Version: 1.30 (December 2014) Model no.: MAPPC800-ENG All information contained in this manual is current as of its creation/publication. B&R reserves the right to change the contents of this manual without notice. The information contained herein is believed to be accurate as of the date of publication;...
Page 2
Chapter 1: General information Chapter 2: Technical data Chapter 3: Installation Chapter 4: Software Chapter 5: Standards and certifications Chapter 6: Accessories Chapter 7: Maintenance and service Appendix A...
Page 5
5.5 One AP900 and one AP800 via onboard SDL..................168 5.5.1 Base system requirements......................... 168 5.5.2 Link modules............................168 5.5.3 Cables..............................168 5.5.4 Settings in BIOS..........................169 5.6 Four Automation Panel 900 systems via onboard SDL................170 5.6.1 Base system requirements......................... 170 Panel PC 800 User's Manual V1.30...
Page 6
1.4.10 Keyboard/Mouse configuration......................205 1.4.11 Remote access configuration......................206 1.4.12 CPU board monitor........................... 207 1.4.13 Baseboard/Panel features.........................208 1.5 Boot................................212 1.6 Security..............................213 1.7 Hard disk security user password......................214 1.8 Hard disk security master password......................215 1.9 Power................................215 Panel PC 800 User's Manual V1.30...
Page 7
6 Windows XP Embedded..........................241 6.1 General information..........................241 6.2 Order data..............................241 6.3 Overview..............................241 6.4 Features with FP2007 (Feature Pack 2007)....................241 6.5 Installation..............................242 6.6 Drivers...............................242 6.6.1 Touch screen driver..........................242 7 Windows Embedded Standard 2009......................243 Panel PC 800 User's Manual V1.30...
Page 8
1 Standards and guidelines..........................267 1.1 CE mark..............................267 1.2 EMC directive............................267 1.3 Low voltage directive..........................267 2 Certifications..............................268 2.1 UL certification............................268 2.2 GOST-R..............................268 Chapter 6 Accessories.................... 269 1 Replacement CMOS batteries........................269 1.1 0AC201.91 / 4A0006.00-000........................269 Panel PC 800 User's Manual V1.30...
Page 9
6.7 5AC600.UPSF-01............................. 282 6.7.1 General information..........................282 6.7.2 Order data............................282 7 External UPS..............................283 7.1 General information..........................283 7.2 Order data..............................283 8 PCI plug-in cards............................285 8.1 5ACPCI.ETH1-01............................285 8.1.1 General information..........................285 8.1.2 Order data............................285 Panel PC 800 User's Manual V1.30...
Page 10
10.2.3 Technical data...........................309 10.2.4 Temperature/Humidity diagram......................310 11 USB media drive............................311 11.1 5MD900.USB2-02........................... 311 11.1.1 General information...........................311 11.1.2 Order data............................311 11.1.3 Interfaces............................311 11.1.4 Technical data........................... 311 11.1.5 Dimensions............................313 11.1.6 Dimensions with front cover......................313 Panel PC 800 User's Manual V1.30...
Page 11
10 Installing and replacing bus units........................ 354 10.1 Procedure............................... 354 11 Installing and replacing adapters......................... 355 11.1 Procedure for the 5AC803.BC01-00 adapter..................355 11.2 Procedure for the 5AC803.BC02-00 adapter..................356 12 Installing and replacing PCIec plug-in cards....................357 Panel PC 800 User's Manual V1.30...
Corrected service life of the battery. • Corrected chipset information for "CPU boards 945GME" on page 65. • Revised "Configuration - Optional components" on page 27. • Updated information about "Pixel errors" on page 181. Table 1: Manual history Panel PC 800 User's Manual V1.30...
Page 14
Updated replacement SSDs "5MMSSD.0060-00" on page 109, "5MMSSD.0060-01" on page 111 and "5MMSSD.0180-00" on page 117. • Updated technical data for HDD "5AC801.HDDI-04" on page 91. • Modified the ambient temperature tables in section "Temperature specifications" on page 28 Table 1: Manual history Panel PC 800 User's Manual V1.30...
Page 15
• Updated the new revisions of 5CFCRD.xxxx-06 CompactFlash cards, see "5CFCRD.xxxx-06" on page 293. • Updated technical data for system units "5PC820.1505-00" on page 53 and "5PC820.1906-00" on page 59. Table 1: Manual history Panel PC 800 User's Manual V1.30...
Electronic devices are never completely failsafe. If the programmable control system, operating/monitoring device or uninterruptible power supply fails, the user is responsible for ensuring that other connected devices, e.g. motors, are brought to a secure state. Panel PC 800 User's Manual V1.30...
(e.g. diskette, CD-ROM, USB flash drive, etc.), a network connection or the Internet. The user is responsible for assessing these dangers, implementing preventive measures such as virus protection programs, firewalls, etc. and making sure that software is only obtained from trusted sources. Panel PC 800 User's Manual V1.30...
For 6 to 30 mm ±0.2 mm For 30 to 120 mm ±0.3 mm For 120 to 400 mm ±0.5 mm For 400 to 1000 mm ±0.8 mm Table 4: Range of nominal sizes Panel PC 800 User's Manual V1.30...
CompactFlash 256 MB Western Digital (SLC) 5CFCRD.0512-03 CompactFlash 512 MB Western Digital (SLC) 5CFCRD.0512-04 CompactFlash 512 MB B&R (SLC) 5CFCRD.1024-03 CompactFlash 1 GB Western Digital (SLC) 5CFCRD.1024-04 CompactFlash 1 GB B&R (SLC) 5CFCRD.2048-03 CompactFlash 2 GB Western Digital (SLC) Panel PC 800 User's Manual V1.30...
Page 21
RS232 extension cable for remote operation of a display unit with touch screen, 1.8 m 9A0014.05 RS232 extension cable for remote operation of a display unit with touch screen, 5 m 9A0014.10 RS232 extension cable for remote operation of a display unit with touch screen, 10 m Panel PC 800 User's Manual V1.30...
Page 22
Microsoft OEM Windows 7 Ultimate 32-bit, Service Pack 1, DVD, multilingual. Only available with a new device. 5SWWI7.1400-MUL Microsoft OEM Windows 7 Ultimate 64-bit, Service Pack 1, DVD, multilingual. Only available with a new device. Panel PC 800 User's Manual V1.30...
Page 23
5SWWXP.0600-GER Microsoft OEM Windows XP Professional Service Pack 3, CD, German. Only available with a new device. 5SWWXP.0600-MUL Microsoft OEM Windows XP Professional Service Pack 3, CD, multilingual. Only available with a new device. Panel PC 800 User's Manual V1.30...
Chapter 2 • Technical data 1 Introduction The Panel PC 800 covers an extremely wide performance range – relying on efficient Intel Atom N270 processors and Core2 Duo processors for applications with exceptionally high performance requirements. Brilliant 15" XGA and 19" SXGA touch screen displays provide a simple and intuitive user interface. Flexibility was raised to a com- pletely new level when designing the PPC800.
If both adapters are used, then a PCIec plug-in card and a slide-in compact drive can be operated in a single device. 2) A fan kit may be necessary for certain system configurations. Figure 2: Configuration - Optional components Panel PC 800 User's Manual V1.30...
(serial interfaces, slide-in drives, USB ports, audio outputs) • Maximum system expansion and power consumption What must be considered when determining the maximum ambient temperature? • Operating the complete system with or without fan kit Panel PC 800 User's Manual V1.30...
✓ 5ACPCI.RAIC-06 (24 hours / standard) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1) Only possible with a CompactFlash card from B&R that is compatible with the device. Table 5: Ambient temperatures Panel PC 800 User's Manual V1.30...
Page 30
3. Incorporating additional drives (slide-in), main memory, additional plug-in cards, etc. can change the temper- ature limits of a PPC800 system. If there is a "✓" next to the component, it can be used at the maximum ambient temperature of the complete system without problems. Panel PC 800 User's Manual V1.30...
The temperature measured approximates the immediate ambient temperature but may also be influenced by neighboring components. The ADI driver containing the B&R Control Center is available in the Downloads section of the B&R website (www.br-automation.com). Panel PC 800 User's Manual V1.30...
The specifications listed correspond to the relative humidity at an ambient temperature of 30°C. More detailed information about specific temperature-dependent humidity values can be found in the technical data for the indi- vidual components. Panel PC 800 User's Manual V1.30...
5 V output, another DC-to-DC converter generates -12 V and applies this to the bus. An additional DC-to-DC converter generates +12 V. The optional add-on UPS (with battery unit) is supplied with 15 V and provides an uninterrupted power supply of the 15 V bus during a power failure. Panel PC 800 User's Manual V1.30...
Table 9: Power calculation for 15" PPC800 Information: The PCIec card must not consume more than a total of 4 W (12 V / 5 V / 3V3)! Panel PC 800 User's Manual V1.30...
Table 10: Power calculation for 19" PPC800 Information: The PCIec card must not consume more than a total of 4 W (12 V / 5 V / 3V3)! Panel PC 800 User's Manual V1.30...
8 Bit Konfigurationsschalter PPC touch IF CMOS profile Switching und Config R´s PPC BKL DC/DC + 12V Switching Schnittstelle nach außen geführt Schnittstelle optional oder intern Figure 5: Block diagram with bus unit 5AC803.BX01-00 Panel PC 800 User's Manual V1.30...
8 Bit Konfigurationsschalter PPC touch IF CMOS profile Switching und Config R´s PPC BKL DC/DC + 12V Switching Schnittstelle nach außen geführt Schnittstelle optional oder intern Figure 6: Block diagram with bus unit 5AC803.BX01-01 Panel PC 800 User's Manual V1.30...
8 Bit Konfigurationsschalter PPC touch IF CMOS profile Switching und Config R´s PPC BKL DC/DC + 12V Switching Schnittstelle nach außen geführt Schnittstelle optional oder intern Figure 7: Block diagram with bus unit 5AC803.BX02-00 Panel PC 800 User's Manual V1.30...
8 Bit Konfigurationsschalter PPC touch IF CMOS profile Switching und Config R´s PPC BKL DC/DC + 12V Switching Schnittstelle nach außen geführt Schnittstelle optional oder intern Figure 8: Block diagram with bus unit 5AC803.BX02-01 Panel PC 800 User's Manual V1.30...
The search provides a detailed list of installed components. Serial number entered here z.B.: AF210168454 wechseln auf den Tab „Serialnummer“ List of installed components shown after searching for a serial number Figure 10: Example of serial number search Panel PC 800 User's Manual V1.30...
The M4 self-locking nut can be used, for example, to fasten a copper strip to a central grounding point in the control cabinet or system where the PPC800 is installed. The largest possible conductor cross section should be used (at least 2.5 mm²). Panel PC 800 User's Manual V1.30...
Information: In SDL mode, the USB transfer rate is limited to USB 1.1. In DVI mode, the maximum USB transfer rate is determined by the USB interface and USB hub on the display device. Panel PC 800 User's Manual V1.30...
Page 43
5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0018-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 5CADVI.0050-00 Table 15: Cable lengths and resolutions for DVI transmission The maximum cable length for DVI transfer is limited to 5 m due to the USB specification. Panel PC 800 User's Manual V1.30...
Table 16: COM1 - Pinout The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by the particular operating system. Panel PC 800 User's Manual V1.30...
Required drivers can only be downloaded from the B&R website, not from manufacturer websites. The PPC800 features a USB 2.0 (Universal Serial Bus) host controller with multiple USB ports, 5 of which are accessible externally for the user. Panel PC 800 User's Manual V1.30...
Page 46
The interfaces, etc. available on the device or module have been numbered as such for easy identification. This numbering may differ from that used by the particular operating system. Each USB port is protected by a maintenance-free "USB current-limiting circuit breaker" (max. 1 A). Panel PC 800 User's Manual V1.30...
Add-on UPS module 5AC600.UPSB-00 Battery unit 5 Ah 5CAUPS.0005-00 UPS cable 0.5 m 5CAUPS.0030-00 UPS cable 3 m Table 24: Add-on UPS slot For additional information about the UPS module, see "Accessories" on page 269. Panel PC 800 User's Manual V1.30...
Pushing the reset button triggers a hardware and PCI reset. The PPC800 is restarted (cold restart). Pressing the reset button does not reset the MTCX processor. Table 26: Reset button Warning! A system reset can result in lost data! Panel PC 800 User's Manual V1.30...
The factory default switch position represents the optimal BIOS default values for this system and should therefore not be changed. The position of the CMOS profile switch is displayed in BIOS Setup and in the B&R ADI Control Center. Panel PC 800 User's Manual V1.30...
From the point when battery capacity is recognized as insufficient, data buffering is intact for approximately another 500 hours. When replacing the battery, data is buffered for approximately 10 minutes by a gold leaf capacitor. Panel PC 800 User's Manual V1.30...
The adapter 5AC803.BC01-00 is required to use PCIec plug-in cards. Information: Only B&R PCIec cards that have been specially designed for the Automation PC 820 and Panel PC 800 can be used. For more information, see "PCIec plug-in cards" on page 78. Panel PC 800 User's Manual V1.30...
5AC803.HS00-02 PPC800 heat sink for CPU board with Atom processor N270 Fan kit 5AC803.FA01-00 PPC800 fan kit for system units without an expansion Optional accessories Adapters Table 33: 5PC820.1505-00 - Order data Panel PC 800 User's Manual V1.30...
Page 54
H0), 5PC600.SX05-00 (starting with Rev. F0), 5PC600.SX05-01 (starting with Rev. F0), 5PC600.SF03-00 (starting with Rev. A0), 5PC810.SX*. 5PC820.1505-00, 5PC820.1906-00. Order cable (5CAUPS.0005-00 or 5CAUPS.0030-00) and battery unit (5AC600.UPSB-00) separately Table 33: 5PC820.1505-00 - Order data Panel PC 800 User's Manual V1.30...
Page 55
Renata 950 mAh Service life 2½ years Removable Yes, accessible from the outside Design Lithium ion Power button Reset button Buzzer Certification cULus GOST-R Controller Boot loader BIOS Table 34: 5PC820.1505-00, 5PC820.1505-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 56
Electrical isolation Operating conditions Height of drop 1 m on industrial surfaces (in original packaging) EN 60529 protection Back: IP20 Front: IP65, dust and sprayed water protection Table 34: 5PC820.1505-00, 5PC820.1505-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 57
The PCI slots available depend on the expansion and bus unit being used. The PCIe slots available depend on the expansion and bus unit being used. Optional with PCIec adapter 5AC803.BC01-00. Optional with slide-in compact adapter 5AC803.BC02-00. Panel PC 800 User's Manual V1.30...
Page 58
81.7 5AC803.SX01-00 5AC803.SX02-00 Figure 14: 5PC820.1505 - Dimensions 3.1.1.6 Cutout Outer contour (Panel PC 800) Cutout Cutout size 415 ±0.5 mm x 312 ±0.5 mm suitable for 5PC820.1505-00 Figure 15: 5PC820.1505-00 - Cutout installation Panel PC 800 User's Manual V1.30...
1 compact PCI Express PPC800 adapter 5AC803.BC02-00 1 compact slide-in PPC800 adapter Bus units 5AC803.BX01-00 PPC800 bus; 1 PCI, 1 slide-in slot 5AC803.BX01-01 PPC800 bus; 1 PCI Express, 1 slide-in slot Table 35: 5PC820.1906-00 - Order data Panel PC 800 User's Manual V1.30...
Page 60
H0), 5PC600.SX05-00 (starting with Rev. F0), 5PC600.SX05-01 (starting with Rev. F0), 5PC600.SF03-00 (starting with Rev. A0), 5PC810.SX*. 5PC820.1505-00, 5PC820.1906-00. Order cable (5CAUPS.0005-00 or 5CAUPS.0030-00) and battery unit (5AC600.UPSB-00) separately Table 35: 5PC820.1906-00 - Order data Panel PC 800 User's Manual V1.30...
Page 61
Renata 950 mAh Service life 2½ years Removable Yes, accessible from the outside Design Lithium ion Power button Reset button Buzzer Certification cULus GOST-R Controller Boot loader BIOS Table 36: 5PC820.1906-00, 5PC820.1906-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 62
Electrical isolation Operating conditions Height of drop 1 m on industrial surfaces (in original packaging) EN 60529 protection Back: IP20 Front: IP65, dust and sprayed water protection Table 36: 5PC820.1906-00, 5PC820.1906-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 63
The PCI slots available depend on the expansion and bus unit being used. The PCIe slots available depend on the expansion and bus unit being used. Optional with PCIec adapter 5AC803.BC01-00. Optional with slide-in compact adapter 5AC803.BC02-00. Panel PC 800 User's Manual V1.30...
Page 64
5AC803.SX01-00 5AC803.SX02-00 Figure 18: 5PC820.1906-00 - Dimensions 3.1.2.6 Cutout Outer contour (Panel PC 800) 412.5 Cutout Cutout size 510 ±0.5 mm x 404 ±0.5 mm suitable for 5PC820.1906-00 Figure 19: 5PC820.1906-00 - Cutout installation Panel PC 800 User's Manual V1.30...
Page 67
400 MHz RAMDAC, resolutions up to 2048 x 1536 @ 75 Hz (QXGA) and 1920 x 1080 @ 85 Hz (HDTV) Mass memory management 2x SATA, 1x IDE Power management ACPI 2.0, S3 Support (suspend to RAM) Table 40: 5PC800.B945-10, 5PC800.B945-11, 5PC800.B945-12, 5PC800.B945-13, 5PC800.B945-14 - Technical data Allocated in main memory. Panel PC 800 User's Manual V1.30...
Suitable for the following system units 5PC820.1505-00 5PC820.1906-00 Certification Mechanical characteristics Materials Aluminum, black-coated with copper heat pipes Dimensions Width 143 mm Height 183.5 mm Depth 60 mm Weight 1200 g Table 42: 5AC803.HS00-00, 5AC803.HS00-01, 5AC803.HS00-02 - Technical data Panel PC 800 User's Manual V1.30...
Table 44: 5MMDDR.0512-01, 5MMDDR.1024-01, 5MMDDR.2048-01 - Technical data Yes, although applies only if all components installed within the complete system have this certification Information: A main memory module can only be replaced at B&R. Panel PC 800 User's Manual V1.30...
Standard PCI 2.2 half-size cards or PCI Express (PCIe) half-size cards can be installed depending on the type of bus unit. They cannot exceed the following dimensions. 177.7 17.4 25.8 Figure 23: Standard half-size PCI card - Dimensions Panel PC 800 User's Manual V1.30...
Page 73
Technical data • Individual components 167.65 11.65 3.65 49.65 57.15 59.05 Figure 24: Standard half-size PCIe card - Dimensions Panel PC 800 User's Manual V1.30...
Table 47: Slide-in slot 1 Information: The SATA I interface allows disks to be replaced during operation (hot plugging). In order to take advantage of this capability, this feature must be supported by the operating system. Panel PC 800 User's Manual V1.30...
19.8 11.65 64.9 Figure 27: PCI Express compact plug-in cards - Dimensions Information: Only B&R PCIec cards that have been specially designed for the Automation PC 820 and Panel PC 800 can be used. Panel PC 800 User's Manual V1.30...
The following characteristics, features and limit values only apply to this individual component and can deviate from those specified for the complete system. For the complete system in which this individual component is used, refer to the data given specifically for that device. Panel PC 800 User's Manual V1.30...
Page 80
A special driver is required in order to operate the Intel 82574 Ethernet controller. Drivers for approved operating systems are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
The following characteristics, features and limit values only apply to this individual component and can deviate from those specified for the complete system. For the complete system in which this individual component is used, refer to the data given specifically for that device. Panel PC 800 User's Manual V1.30...
Page 82
If an error occurs in the following states, then the green LED blinks over the red LED: • BASIC_ETHERNET • PRE_OPERATIONAL_1 • PRE_OPERATIONAL_2 • READY_TO_OPERATE Status Green Error "S/E" LED Table 60: Status/Error LED as Error LED - POWERLINK V2 operating mode Panel PC 800 User's Manual V1.30...
Page 83
Error code indicated by red status LED RAM error • • • Pause • • • Pause Hardware error • • Pause • • Pause Table 62: Status/Error LED as Error LED - System failure error codes Panel PC 800 User's Manual V1.30...
Page 84
If the card is operated with Automation Runtime, then the card number switch must match the slot number in Automation Studio. Figure 29: Integrating the POWERLINK plug-in card in Automation Studio 3.8.4.3.5 SRAM The 2-port 5ACPCC.MPL0-00 POWERLINK card has 512 kB SRAM. Panel PC 800 User's Manual V1.30...
Typ. 3 s (from 0 rpm to read access) MTBF 750,000 POH S.M.A.R.T. support Interface SATA Access time 5.6 ms Data transfer rate Internal Max. 450 Mbit/s To/From host Max. 150 MB/s (Ultra DMA mode 5) Table 65: 5AC801.HDDI-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 86
Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 15% per hour. Slide-in compact installation. 3.9.1.4 Temperature humidity diagram Operation Temperature [°C] Figure 30: 5AC801.HDDI-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
Max. 84.6 Mbit/s To/From host Max. 150 MB/s (Ultra DMA mode 5) Positioning time Minimum (track to track) 1.5 ms Nominal (read only) 12 ms Maximum (read only) 22 ms Table 67: 5AC801.HDDI-02 - Technical data Panel PC 800 User's Manual V1.30...
Page 88
24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 15% per hour. Maximum humidity at 29°C. Maximum humidity at 40°C. Slide-in compact installation. 3.9.2.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 31: 5AC801.HDDI-02 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
PIO mode 0-4, multiword DMA mode 0-2, UDMA mode 0-6 Data transfer rate Internal Max. 1175 Mbit/s To/From host Max. 150 MB/s (SATA I), max. 300 MB/s (SATA II) Table 69: 5AC801.HDDI-03 - Technical data Panel PC 800 User's Manual V1.30...
Page 90
24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 30% per hour. Slide-in compact installation. 3.9.3.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 32: 5AC801.HDDI-03 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
Internal Max. 147 MB/s To/From host Max. 150 MB/s (SATA I), max. 300 MB/s (SATA II) Positioning time Nominal (read only) 11 ms Maximum (read only) 21 ms Table 71: 5AC801.HDDI-04 - Technical data Panel PC 800 User's Manual V1.30...
Page 92
24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 20% per hour. Slide-in compact installation. 3.9.4.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 33: 5AC801.HDDI-04 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
<1 unrecoverable error in 10 bit read accesses MTBF 2,000,000 hours Power on/off cycles 50,000 S.M.A.R.T. support Interface SATA Maintenance None Sequential read Max. 250 MB/s Sequential write Max. 170 MB/s Table 73: 5AC801.SSDI-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 94
SSDSA2SH032G1 Table 73: 5AC801.SSDI-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. Slide-in compact installation. Panel PC 800 User's Manual V1.30...
Page 95
Technical data • Individual components 3.9.5.4 Temperature/Humidity diagram Storage Operation Transport Temperature [°C] Figure 34: 5AC801.SSDI-00 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
Page 96
Transfer size [kB] 5AC801.SSDI-00 5AC801.HDDI-00 Figure 35: 5AC801.SSDI-00 - ATTO disk benchmark v2.34 - cyclic read 1024 2048 4096 8192 Transfer size [kB] 5AC801.SSDI-00 5AC801.HDDI-00 Figure 36: 5AC801.SSDI-00 - ATTO disk benchmark v2.34 - cyclic write Panel PC 800 User's Manual V1.30...
Max. 550 MB/s with SATA 6 Gbit/s Max. 280 MB/s with SATA 3 Gbit/s Sequential write Max. 475 MB/s with SATA 6 Gbit/s Max. 245 MB/s with SATA 3 Gbit/s Table 75: 5AC801.SSDI-01 - Technical data Panel PC 800 User's Manual V1.30...
Page 98
Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. Slide-in compact installation. 3.9.6.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 37: 5AC801.SSDI-01 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
Max. 550 MB/s with SATA 6 Gbit/s Max. 280 MB/s with SATA 3 Gbit/s Sequential write Max. 520 MB/s with SATA 6 Gbit/s Max. 260 MB/s with SATA 3 Gbit/s Table 77: 5AC801.SSDI-02 - Technical data Panel PC 800 User's Manual V1.30...
Page 100
Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. Slide-in compact installation. 3.9.7.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 38: 5AC801.SSDI-02 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
Max. 25,000 (random) Endurance MLC flash Guaranteed data volume Guaranteed 35 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 79: 5AC801.SSDI-03, 5AC801.SSDI-03 - Technical data Panel PC 800 User's Manual V1.30...
Page 102
Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written Slide-in compact installation. 3.9.8.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 39: 5AC801.SSDI-03 ≤ Rev. C0 - Temperatur Luftfeuchtediagramm Panel PC 800 User's Manual V1.30...
Page 103
Technical data • Individual components Operation Temperature [°C] Figure 40: 5AC801.SSDI-03 ≥ Rev. D0 - Temperatur Luftfeuchtediagramm Panel PC 800 User's Manual V1.30...
<1 unrecoverable error in 10 bit read accesses MTBF 1,500,000 hours S.M.A.R.T. support Interface SATA Maintenance None Sequential read Max. 510 MB/s Sequential write Max. 450 MB/s Table 81: 5AC801.SSDI-04, 5AC801.SSDI-04 - Technical data Panel PC 800 User's Manual V1.30...
Page 105
Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written Slide-in compact installation. 3.9.9.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 41: 5AC801.SSDI-04 ≤ Rev. C0 - Temperatur Luftfeuchtediagramm Panel PC 800 User's Manual V1.30...
Page 106
Technical data • Individual components Operation Temperature [°C] Figure 42: 5AC801.SSDI-04 ≥ Rev. D0 - Temperatur Luftfeuchtediagramm Panel PC 800 User's Manual V1.30...
Page 108
Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written Slide-in compact installation. 3.9.10.4 Temperature humidity diagram Operation Temperature [°C] Figure 43: 5AC801.SSDI-05 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
IOPS 4k read 15,000 4k write Typical 23,000 Maximum 80,000 Endurance MLC flash Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 85: 5MMSSD.0060-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 110
Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. 3.9.11.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 44: 5MMSSD.0060-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Environmental conditions Temperature Operation 0 to 70°C -30 to 85°C Storage -40 to 85°C Transport -40 to 85°C Table 87: 5MMSSD.0060-01, 5MMSSD.0060-01 - Technical data Panel PC 800 User's Manual V1.30...
Page 112
Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written 3.9.12.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 45: 5MMSSD.0060-01 ≤ Rev. C0 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
Page 113
Technical data • Individual components Operation Temperature [°C] Figure 46: 5MMSSD.0060-01 ≥ Rev. D0 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
Max. 35,000 (random) Endurance MLC flash Guaranteed data volume Guaranteed 74 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 89: 5MMSSD.0128-01, 5MMSSD.0128-01 - Technical data Panel PC 800 User's Manual V1.30...
Page 115
Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written 3.9.13.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 47: 5MMSSD.0128-01 ≤ Rev. C0 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
Page 116
Technical data • Individual components Operation Temperature [°C] Figure 48: 5MMSSD.0128-01 ≥ Rev. D0 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
IOPS 4k read 50,000 4k write Typical 60,000 Maximum 80,000 Endurance MLC flash Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 91: 5MMSSD.0180-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 118
Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. 3.9.14.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 49: 5MMSSD.0180-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
4k write Max. 35,000 (random) Endurance MLC flash Guaranteed data volume Guaranteed 148 TBW Compatibility SATA 3.0 compliant ACS-2 SSD Enhanced SMART ATA feature set Native Command Queuing (NCQ) Table 93: 5MMSSD.0256-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 120
Yes, although applies only if all components installed within the complete system have this certification IOPS: Random read and write input/output operations per second. TBW: Terabytes written 3.9.15.4 Temperature humidity diagram Operation Temperature [°C] Figure 50: 5MMSSD.0256-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
Dimensions Width 22 mm Height 172.5 mm Depth 150 mm Weight 328 g Table 95: 5AC801.ADAS-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
Typ. 3 s (from 0 rpm to read access) MTBF 750,000 POH S.M.A.R.T. support Interface SATA Access time 5.6 ms Data transfer rate Internal Max. 450 Mbit/s To/From host Max. 150 MB/s (Ultra DMA mode 5) Table 97: 5AC801.HDDS-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 123
Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 15% per hour. Slide-in compact installation. 3.9.17.4 Temperature humidity diagram Operation Temperature [°C] Figure 51: 5AC801.HDDS-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
Service life 60000 POH (power-on hours) Interface SATA Startup time Max. 19 seconds (from 0 rpm to read access) Max. 19 seconds (from 0 rpm to read access) Table 99: 5AC801.DVDS-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 125
Temperature [°C] Figure 52: 5AC801.DVDS-00 - Temperature humidity diagram 3.9.18.5 Hot plugging Hardware revision B0 of the 5AC801.DVDS-00 slide-in DVD-ROM does not offer SATA hot plugging functionality. Hot plugging is possible for other hardware revisions. Panel PC 800 User's Manual V1.30...
Service life 60000 POH (power-on hours) Interface SATA Startup time Max. 14 seconds (from 0 rpm to read access) Max. 15 seconds (from 0 rpm to read access) Table 101: 5AC801.DVRS-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 127
Temperature specifications refer to operation at 500 meters. The maximum ambient temperature is typically derated by 1°C per 1000 meters (starting at 500 meters above sea level). Drive surface temperature. Panel PC 800 User's Manual V1.30...
Page 128
Technical data • Individual components 3.9.19.4 Temperature humidity diagram Storage Operation Temperature [°C] Figure 53: 5AC801.DVRS-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
Optional accessories Drives 5ACPCI.RAIC-04 160 GB SATA hard disk, replacement part for 5ACPCI.RAIC-03; note: Please see the manual for information about using this hard disk. Table 102: 5ACPCI.RAIC-03 - Order data Panel PC 800 User's Manual V1.30...
Page 130
Max. 200 g, 0.5 ms; no damage Altitude Operation -300 to 3048 m Storage -300 to 12192 m Mechanical characteristics Installation Fixed Dimensions Width 70 mm Length 100 mm Height 9.5 mm Table 103: 5ACPCI.RAIC-03 - Technical data Panel PC 800 User's Manual V1.30...
Page 131
The 160 GB 5ACPCI.RAIC-04 SATA HDD is available as a replacement hard disk. For instructions on replacing the drive, see 7 "Maintenance and service", section 14 "Replacing a PCI SATA RAID hard disk in a RAID 1 set" on page 359. Panel PC 800 User's Manual V1.30...
5 to 500 Hz: max. 5 g; duration 0.5 octaves per minute; no damage Transport 5 to 500 Hz: max. 5 g; duration 0.5 octaves per minute; no damage Table 105: 5ACPCI.RAIC-04 - Technical data Panel PC 800 User's Manual V1.30...
Page 133
Maximum humidity at 40°C. Operation in areas prone to vibration and shock can affect performance negatively (reduction of transfer rate). 3.9.21.4 Temperature humidity diagram Operation Temperature [°C] Figure 56: 5ACPCI.RAIC-04 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
Optional accessories Drives 5MMHDD.0250-00 250 GB SATA hard disk; replacement for 5AC801.HDDI-03 and 5ACPCI.RAIC-05; note: please see the manual for information about using this hard disk Table 106: 5ACPCI.RAIC-05 - Order data Panel PC 800 User's Manual V1.30...
Page 135
Temperature values at an elevation of 305 meters. The temperature specification must be reduced linearly by 1°C every 305 meters. The temperature increase and decrease can be a maximum of 20°C per hour. Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Panel PC 800 User's Manual V1.30...
Page 136
The 250 GB 5MMHDD.0250-00 SATA HDD is available as a replacement hard disk. For information about performing a replacement, see "Replacing a PCI SATA RAID hard disk in a RAID 1 set" on page 359. Panel PC 800 User's Manual V1.30...
Optional accessories Drives 5MMHDD.0500-00 500 GB SATA hard disk; replacement for 5AC801.HDDI-04, 5AC901.CHDD-01 and 5ACPCI.RAIC-06; note: please see the manual for information about using this hard disk Table 108: 5ACPCI.RAIC-06 - Order data Panel PC 800 User's Manual V1.30...
Page 138
1000 g and 2 ms duration; no unrecoverable errors Transport 1000 g and 2 ms duration; no unrecoverable errors Altitude Operation -305 to 3048 m Storage -305 to 12192 m Mechanical characteristics Installation Fixed Table 109: 5ACPCI.RAIC-06 - Technical data Panel PC 800 User's Manual V1.30...
Page 139
The 500 GB 5MMHDD.0500-00 SATA HDD is available as a replacement hard disk. For information about performing a replacement, see "Replacing a PCI SATA RAID hard disk in a RAID 1 set" on page 359. Panel PC 800 User's Manual V1.30...
Max. 150 MB/s (SATA I), max. 300 MB/s (SATA II) Positioning time Minimum (track to track) 1 ms Nominal (read only) 14 ms Maximum (read only) 30 ms Table 111: 5MMHDD.0250-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 141
Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 30% per hour. 3.9.24.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 61: 5MMHDD.0250-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
Typ. 3.5 s (from 0 rpm to read access) Service life 5 years MTBF 1,000,000 POH S.M.A.R.T. support Interface SATA Access time 5.5 ms Supported transfer modes SATA II Table 113: 5MMHDD.0500-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 143
Standard operation refers to 333 POH (power-on hours) per month. 24-hour operation refers to 732 POH (power-on hours) per month. Humidity gradient: Maximum 20% per hour. 3.9.25.4 Temperature humidity diagram Storage Operation Transport Temperature [°C] Figure 62: 5MMHDD.0500-00 - Temperature humidity diagram Panel PC 800 User's Manual V1.30...
General information Number of fans Speed Max. 6100 rpm Noise level 21 dB Service life 29,000 hours at 70°C 95,000 hours at 20°C Type Double ball bearings Certification GOST-R Table 115: 5AC803.FA01-00 - Technical data Panel PC 800 User's Manual V1.30...
Fan 3: 5 dB Service life Fans 1, 2: 29,000 hours at 70°C, 95,000 hours at 20°C Fan 3: 60,000 hours (at 40°C) Type Double ball bearings Certification GOST-R Table 117: 5AC803.FA02-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 146
Fans 1, 2: 40 mm Fan 3: 70 mm Height Fans 1, 2: 40 mm Fan 3: 70 mm Depth Fans 1, 2: 10 mm Fan 3: 15 mm Table 117: 5AC803.FA02-00 - Technical data Panel PC 800 User's Manual V1.30...
Fan 4: 5 dB Service life Fan 1, 2, 3: 29,000 hours at 70°C, 95,000 hours at 20°C Fan 4: ±60,000 at 40°C Type Double ball bearings Certification GOST-R Table 119: 5AC803.FA03-00 - Technical data Panel PC 800 User's Manual V1.30...
Page 148
Fan 1, 2, 3: 40 mm Fan 4: 70 mm Height Fan 1, 2, 3: 40 mm Fan 4: 70 mm Depth Fan 1, 2, 3: 10 mm Fan 4: 15 mm Table 119: 5AC803.FA03-00 - Technical data Panel PC 800 User's Manual V1.30...
Clamping blocks are designed to clamp a maximum thickness of 10 mm and minimum thickness of 2 mm. A hex key (3 mm) is needed to tighten and loosen the screws. The maximum torque when tightening the clamp is 0.5 Nm. Panel PC 800 User's Manual V1.30...
Page 150
Installation • Installation Devices must be installed on flat, clean and burr-free surface; uneven areas can cause damage to the display when the screws are tightened or intrusion of dust and water. Panel PC 800 User's Manual V1.30...
Figure 67: Mounting orientation 0° and +/- 45° In order to facilitate natural air circulation, devices must be mounted according to the spacing indicated in the section "Spacing for air circulation" on page 154. Panel PC 800 User's Manual V1.30...
1.3.2 Mounting orientation with 5AC801.DVRS-00 0° Figure 68: Mounting orientation with 5AC801.DVRS-00 In order to facilitate natural air circulation, devices must be mounted according to the spacing indicated in the section "Spacing for air circulation" on page 154. Panel PC 800 User's Manual V1.30...
1.3.3 Mounting orientation with 5AC801.DVDS-00 0° Figure 69: Mounting orientation with 5AC801.DVDS-00 In order to facilitate natural air circulation, devices must be mounted according to the spacing indicated in the section "Spacing for air circulation" on page 154. Panel PC 800 User's Manual V1.30...
In order to guarantee sufficient air circulation, allow the specified amount of space above, below, to the side and behind the Panel PC 800 devices. The minimum specified spacing is indicated in the following diagram. This applies to all Panel PC 800 variants.
The maximum torque for the locating screws is 0.5 Nm. Locating screws Flex radius Locating screws Figure 71: Flex radius - Cable connection (sample image) Information: The specified flex radius is listed in the technical data for the respective cable. Panel PC 800 User's Manual V1.30...
• Note the line shielding concept; all connected data cables are used as shielded lines. Functional ground is indicated on the B&R device with the following symbol: Control cabinet Grounding strip Ground connection Power supply Min. 2.5 m m² Min. 2.5 m m² Figure 72: Grounding concept Panel PC 800 User's Manual V1.30...
(www.br-automation.com). The B&R Control Center uses the B&R Automation Device Interface (ADI). A separate application can be developed if it is necessary to collect historical data. Information: Software development kits such as the ADI .NET SDK are available on the B&R website (www.br- automation.com). Panel PC 800 User's Manual V1.30...
More information available www.passmark.com. The following screenshots are based on Passmark BurnInTest Pro V4 and a 2-slot APC810 with DVD. Figure 73: Settings for Passmark BurnInTest Pro V4 and a 2-slot APC810 with DVD Panel PC 800 User's Manual V1.30...
Page 159
Windows. The test USB must then be deselected, and the USB flash drives must be configured as the testing device in the disk properties. Information: Serial loopback plugs are relatively easy to create. Simply connect several pins on the serial interface with wires. Panel PC 800 User's Manual V1.30...
The following table lists the AP900 devices that can be connected on the same line with an AP800 device. Automation Panel 800 Automation Panel 900 5AP820.1505-00 5AP920.1505-01 5AP951.1505-01 5AP980.1505-01 5AP981.1505-01 5AP880.1505-00 5AP920.1505-01 5AP951.1505-01 5AP980.1505-01 5AP981.1505-01 Table 121: Selecting display units Panel PC 800 User's Manual V1.30...
DVI-D cable, 10 m 10 m ±100 mm 9A0014.02 RS232 extension cable for remote operation of a display unit with touch screen, 1.8 m 1.8 m ±50 mm Table 124: Cables for DVI configurations Panel PC 800 User's Manual V1.30...
USB support is not possible on the Automation Panel 900 in these cases since USB is limited to 5 m. Information: When transferring data via DVI, it is not possible to read statistical values from Automation Panel 900 devices. 5.2.5 BIOS settings No special BIOS settings are necessary for operation. Panel PC 800 User's Manual V1.30...
SDL cable, 30 m 30 m ±100 mm 5CASDL.0018-03 SDL flex cable, 1.8 m 1.8 m ±20 mm 5CASDL.0050-03 SDL flex cable, 5 m 5 m ±45 mm Table 128: Cables for SDL configurations Panel PC 800 User's Manual V1.30...
For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Panel PC 800 User's Manual V1.30...
PDF file from the B&R website at www.br-automation.com. 5.4.2.1 Cable lengths and resolutions for SDL transmission The following table lists the relationship between segment lengths and maximum resolution depending on the SDL cable being used: Panel PC 800 User's Manual V1.30...
For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Panel PC 800 User's Manual V1.30...
For a selection of SDL cables for connecting the AP900 display to an AP900 display, see "Cables" on page 164. For a selection of SDL cables for connecting the AP800 display to an AP900 display, see "Cables" on page 166. Information: For detailed information regarding cables, see the chapter "Accessories". Panel PC 800 User's Manual V1.30...
For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Panel PC 800 User's Manual V1.30...
Connections for SDL In and SDL Out; transmission of display, touch screen, USB 1.1, matrix key and service data; 24 VDC (order screw clamp 0TB103.9 or cage clamp 0TB103.91 separately) Table 136: Link modules 5.6.3 Cables Select an Automation Panel 900 cable from the following table. Panel PC 800 User's Manual V1.30...
For detailed information, see the user's manual for the B&R Industrial PC being used. Touch screen functionality COM C must be enabled in BIOS in order to operate the panel touch screen connected to the monitor/panel interface ("Advanced - Baseboard/Panel features - Legacy devices"). Panel PC 800 User's Manual V1.30...
Windows CE starts the touch screen calibration sequence during its first boot in its default configuration (i.e. de- livered state). 6.7 Automation Runtime / Visual Components The touch screen must be calibrated once for the customer application when commissioning the device and project. Panel PC 800 User's Manual V1.30...
7.1 Locally on the PPC800 Many different peripheral USB devices can be connected to the 5 USB interfaces on the Panel PC 800. These can each handle a load of up to 1 A. The maximum transfer rate is USB 2.0.
USB memory media e.g. flash drive USB input devices USB drives USB pointing devices e.g. keyboard e.g. CD-ROM drive e.g. mouse Figure 81: Remote connection of USB peripheral devices on the APC900 via DVI Panel PC 800 User's Manual V1.30...
USB memory media e.g. flash drive USB drives USB input devices USB pointing devices e.g. CD-ROM drive e.g. keyboard e.g. mouse Figure 82: Remote connection of USB peripheral devices on the APC800/900 via SDL Panel PC 800 User's Manual V1.30...
Moves to the next item Enter Selects an item or opens a submenu Returns to the previous menu Ctrl+E Saves any changed settings and exits setup Table 139: BIOS-relevant keys in the RAID Configuration Utility Panel PC 800 User's Manual V1.30...
Figure 86: RAID Configuration Utility - Create RAID set - Striped "Auto configuration" Auto configuration optimizes all settings. "Manual configuration" Allows the first and second HDD to be specified as well as the "Chunk size" (= block size, application-dependent). Panel PC 800 User's Manual V1.30...
1 ST96023AS Chunk Size Previous Menu Enter Select Ctrl-E Exit First HDD Figure 88: RAID Configuration Utility - Delete RAID set An existing RAID set can be deleted using the "Delete RAID set" menu option. Panel PC 800 User's Manual V1.30...
Figure 90: RAID Configuration Utility - Resolve conflicts Conflicts in a RAID set can be resolved using the "Resolve conflicts" menu option. This function is only available if the status of the hard disk is "Conflict". Panel PC 800 User's Manual V1.30...
Individual hard disks can be configured using the "Low level format" menu option. This can only be done if a RAID set is not configured. A low level format of a hard disk takes approx. 40 minutes. Panel PC 800 User's Manual V1.30...
• By using a screensaver 10 Pixel errors Information: Displays may contain defective pixels (dead/stuck pixels) that result from the manufacturing process. These flaws are not grounds for reclamation or initiating a warranty claim. Panel PC 800 User's Manual V1.30...
(e.g. Windows XP boot logo). HD resolution is displayed corrected again when Windows XP or Windows 7 is booted properly with an installed graphics driver. Panel PC 800 User's Manual V1.30...
To enter BIOS Setup, the <Del> key must be pressed after the USB controller has been initialized as soon as the following message appears on the screen (during POST): "Press DEL to run SETUP". Panel PC 800 User's Manual V1.30...
Page 184
Auto-Detecting Sec Slave...IDE Hard Disk Sec Master: SILICONSYSTEMS INC 4GB 240-0230 Sec Slave : SILICONSYSTEMS INC 4GB 240-0230 Auto-Detecting USB Mass Storage Devices .. 00 USB mass storage devices found an configured. Figure 92: Boot Screen Panel PC 800 User's Manual V1.30...
Jumps to the last BIOS menu item or object F2 / F3 Changes the colors of BIOS Setup Resets any changes Loads and configures CMOS default values for all BIOS settings Saves and exits Exits a submenu Table 141: BIOS-relevant keys Panel PC 800 User's Manual V1.30...
Boot counter Displays the boot counter; each restart increases None the counter by one (max. 16777215) Running time Displays the runtime in hours (max. 65535) None Table 142: 945GME Main menu - Configuration options Panel PC 800 User's Manual V1.30...
"CPU board monitor" on page 207 Baseboard/Panel fea- Displays and configures device-specific settings Enter Opens the submenu tures see "Baseboard/Panel features" on page 208 Table 143: 945GME Advanced menu Panel PC 800 User's Manual V1.30...
80°C, 85°C, 90°C, 95°C, Temperature setting for the critical trip point. which the operating system automatically shuts 100°C, 105°C, 110°C Configurable in increments of 5 degrees. down Table 144: 945GME Advanced - ACPI configuration - Configuration options Panel PC 800 User's Manual V1.30...
"PCI IRQ resource exclusion" on page PCI interrupt routing Configures PCI interrupt routing Enter Opens the submenu see "PCI interrupt routing" on page 191 Table 145: 945GME Advanced - PCI configuration - Configuration options Panel PC 800 User's Manual V1.30...
Page 190
IRQ interrupt routing for Legacy ISA devices Allocated Allocated by the system - cannot be used Available Available - can be used Reserved Reserved - cannot be used Table 146: 945GME Advanced - PCI IRQ resource exclusion - Configuration options Panel PC 800 User's Manual V1.30...
Page 191
Assigns the PIRQ as the 1st exclusive PCI IRQ sharing). Information: This is only displayed if a PIRQ is con- figured manually (e.g. 5). Table 147: 945GME Advanced - PCI interrupt routing - Configuration options Panel PC 800 User's Manual V1.30...
Page 192
PCIE port 2 (IF slot) This option enables or disables the PCI Express Auto Automatic assignment by BIOS and the operat- interface function. ing system Table 148: 945GME Advanced - PCI Express configuration - Configuration options Panel PC 800 User's Manual V1.30...
Page 193
Programmable Interrupt Controller) on Disabled Disables this function PCIE port 3. The IRQ resources available to the system are expanded when APIC mode is en- abled. Table 148: 945GME Advanced - PCI Express configuration - Configuration options Panel PC 800 User's Manual V1.30...
Local flat panel type This option can be used to set a predefined profile Auto Automatic detection and configuration using the for the LVDS channel. EDID data Table 149: 945GME Advanced - Graphics configuration - Configuration options Panel PC 800 User's Manual V1.30...
Page 195
DVI monitors are reconnected, even if only one of them was connected and enabled during a previ- ous boot. Table 149: 945GME Advanced - Graphics configuration - Configuration options Panel PC 800 User's Manual V1.30...
Disables C3 support C4 config Power management for the Intel Core Duo Standard Standard C4 support processor Enhanced Enhanced C4 support Disabled Disables C4 support Table 150: 945GME Advanced - CPU configuration - Configuration options Panel PC 800 User's Manual V1.30...
Fine-tunes the power saving function on an ACPI Enabled Brings the processor to C4 if the operating sys- operating system tem is initiated in a C3 state Disabled Disables this function Table 151: 945GME Advanced - Chipset settings - Configuration options Panel PC 800 User's Manual V1.30...
Enables this function the hard drive Disabled Disables this function IDE detect time out (sec) Configures the time overrun limit for ATA/ATAPI 0, 5, 10, 15, 20, 25, 30, 35 Time setting in seconds device detection. Panel PC 800 User's Manual V1.30...
Page 200
Enables this function Disabled Disables this function 32 bit data transfer Enables 32-bit data transfer Enabled Enables this function Disabled Disables this function Table 154: 945GME Advanced - Primary IDE master - Configuration options Panel PC 800 User's Manual V1.30...
Page 201
Enables this function Disabled Disables this function 32 bit data transfer Enables 32-bit data transfer Enabled Enables this function Disabled Disables this function Table 155: 945GME Advanced - Primary IDE slave - Configuration options Panel PC 800 User's Manual V1.30...
Page 202
Enables this function Disabled Disables this function 32 bit data transfer Enables 32-bit data transfer Enabled Enables this function Disabled Disables this function Table 156: 945GME Advanced - Secondary IDE master - Configuration options Panel PC 800 User's Manual V1.30...
Page 203
Enables this function Disabled Disables this function 32 bit data transfer Enables 32-bit data transfer Enabled Enables this function Disabled Disables this function Table 157: 945GME Advanced - Secondary IDE slave - Configuration options Panel PC 800 User's Manual V1.30...
Hard disk drive An HDD-formatted drive can be used as an FDD (e.g. zip drive) to start the system. Table 158: 945GME Advanced - USB configuration - Configuration options Panel PC 800 User's Manual V1.30...
Loads updates to the processor via the serial in- Enabled Enables this function terface during system startup Disabled Disables this function Information: Disabling this option reduced the boot time. Table 160: 945GME Advanced - Remote access configuration - Configuration options Panel PC 800 User's Manual V1.30...
Displays the current voltage of the 5 volt supply None +12Vin Displays the current voltage of the 12 volt supply None VRTC Displays the battery voltage in volts None Table 161: 945GME Advanced - CPU board monitor - Configuration options Panel PC 800 User's Manual V1.30...
(e.g. to give the device a unique ID) and can only be changed using the "B&R Control Center" includ- ed with the ADI driver. Table 162: 945GME Advanced - Baseboard/Panel features - Configuration options Panel PC 800 User's Manual V1.30...
Page 209
Fan speed Displays the fan speed for the selected panel None Keys/LEDs Displays the available keys and LEDs on the se- None lected panel Table 163: 945GME Advanced - Panel control - Configuration options Panel PC 800 User's Manual V1.30...
Page 210
Displays the speed of housing fan 2 None Case 3 Displays the speed of housing fan 3 None Case 4 Displays the speed of housing fan 4 None Table 164: 945GME Advanced - Baseboard monitor - Configuration options Panel PC 800 User's Manual V1.30...
Page 211
Enables the controller (ETH2) on and off Disabled Disables the controller ETH2 MAC address Displays the MAC address of the Ethernet 2 con- None troller Table 165: 945GME Advanced - Legacy devices - Configuration options Panel PC 800 User's Manual V1.30...
This option can be used to attempt to restart the Enabled Enables this function operating system automatically if it fails to start Disabled Disables this function the first time. Table 166: 945GME Boot menu - Configuration options Panel PC 800 User's Manual V1.30...
BIOS settings. Change user password Function for entering/changing a user password. Enter Password entry The user password allows the user to edit only certain BIOS settings. Table 167: 945GME Security menu - Configuration options Panel PC 800 User's Manual V1.30...
The user password allows the user to edit only certain BIOS settings. Table 168: 945GME Security - Hard disk security user password Panel PC 800 User's Manual V1.30...
Select Item Resume On PME# [Disabled] Change Option Resume On RTC Alarm [Disabled] General Help Save and Exit Power Button Mode [On/Off] Exit v02.59 (C)Copyright 1985-2005, American Megatrends, Inc. Figure 122: 945GME Power Menü Panel PC 800 User's Manual V1.30...
Page 216
Disabled Disables this function Power button mode This function determines what the power button On/Off Switches the system on/off does. Suspend Suppresses this function Table 170: 945GME Power menu - Configuration options Panel PC 800 User's Manual V1.30...
This option loads the CMOS default values de- OK / Cancel fined by the DIP switch settings. These values are loaded for all BIOS settings. Table 171: 855GME (XTX) Exit menu - Configuration options Panel PC 800 User's Manual V1.30...
Plug & Play O/S PCI latency timer Allocate IRQ to PCI VGA Allocate IRQ to SMBUS HC Allocate IRQ to PCIEX2 PCI IRQ resource exclusion Table 175: 945GME Advanced - PCI configuration - Overview of profile settings Panel PC 800 User's Manual V1.30...
Page 219
Disabled Execute disable bit Enabled Enabled Core multi-processing Enabled Enabled Intel(R) SpeedStep(tm) tech. Automatic Automatic Max. CPU frequency xxxx MHz xxxx MHz Table 178: 945GME Advanced - CPU configuration - Overview of profile settings Panel PC 800 User's Manual V1.30...
Page 220
PIO mode Auto Auto DMA mode Auto Auto S.M.A.R.T. Auto Auto 32Bit data transfer Enabled Enabled Secondary IDE slave Type Auto Auto Table 182: 945GME Advanced - IDE configuration - Overview of profile settings Panel PC 800 User's Manual V1.30...
Page 221
Board I/O Board ETH2 Board power Power supply Slide-in drive 1 IF slot Case 1 Case 2 Case 3 Case 4 Legacy devices Table 186: 945GME Advanced - Baseboard/Panel features - Overview of profile settings Panel PC 800 User's Manual V1.30...
Secondary slave IDE MONITOR MONITOR Resume on ring Disabled Disabled Resume on PME# Disabled Disabled Resume on RTC alarm Disabled Disabled Power button mode On/Off On/Off Table 189: 945GME Power - Overview of profile settings Panel PC 800 User's Manual V1.30...
Send the industrial PC to B&R for testing. to CMOS 11x short Cache error / external cache bad: Defective L2 cache on the main- Send the industrial PC to B&R for testing. board Table 190: 945GME BIOS - POST messages Panel PC 800 User's Manual V1.30...
APIC IRQ 22 PIRQ H USB UHCI-0 USB EHCI B0:D29:F0 B0:D29:F7 APIC IRQ 23 PCI 1 PCI 2 Figure 124: PCI and PCIe routing with enabled APIC for 945GME CPU boards and BIOS versions ≥ 1.15 Panel PC 800 User's Manual V1.30...
This information can be found on the following BIOS Setup screen: • After switching on the PPC800, BIOS Setup can be accessed by pressing <Del>. • From the BIOS main menu "Advanced", select "Baseboard/Panel features" and then "Panel control". Panel PC 800 User's Manual V1.30...
5. The following boot menu will be shown after startup: 1. Upgrade AMI BIOS for B945 2. Exit Item 1: BIOS is automatically upgraded (default after 5 seconds). Item 2: Returns to the shell (MS-DOS) Panel PC 800 User's Manual V1.30...
Page 228
PC. 6. The system must be rebooted after a successful upgrade. 7. Reboot and press <Del> to enter BIOS Setup and load the setup defaults, then select "Save changes and exit". Panel PC 800 User's Manual V1.30...
Automatically updates the SDLR controller on the Automation Panel 3 interface 2.5 Upgrade all SDLR (AP800/AP900) Automatically updates all SDLR controllers on all Automation Panels on the monitor/panel interface (default selec- tion after 5 sec) Panel PC 800 User's Manual V1.30...
MTCX or SDLT (to put the system in standby mode) before powering the system off and back on. If this is not done, the firmware upgrade will not work since the UPS is buffering the system. Panel PC 800 User's Manual V1.30...
In Windows Explorer, go to the "Tools" menu, select "Folder options" and open the "View" tab. Then deselect the option "Hide protected operating system files (Recommended)" (enabled by default) and enable the option "Show hidden files and folders". Panel PC 800 User's Manual V1.30...
Page 232
Figure 130: Creating a bootable diskette in Windows XP - Step 4 Figure 131: Creating a bootable diskette in Windows XP - Step 5 Now all files (selected) except Command.com, IO.sys and MSDOS.sys can be deleted. Panel PC 800 User's Manual V1.30...
Information on creating an MS-DOS boot diskette can be found in section see "Creating an MS-DOS boot diskette in Windows XP" on page 231. The files from the diskette are then copied to the hard drive. Panel PC 800 User's Manual V1.30...
Information on creating an MS-DOS boot diskette can be found in section see "Creating an MS-DOS boot diskette in Windows XP" on page 231. The files from the diskette are then copied to the hard drive. Panel PC 800 User's Manual V1.30...
✓ ✓ ✓ 1024 x 768 ✓ ✓ ✓ 1280 x 1024 ✓ ✓ ✓ 1600 x 1200 ✓ ✓ ✓ 1920 x 1440 Table 197: Tested resolutions and color depths for RGB signals Panel PC 800 User's Manual V1.30...
4.5 Drivers Current drivers for all approved operating systems are available in the Downloads section of the B&R website www.br-automation.com. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
The memory used by additional language packs is not taken into account in the minimum size of the disk. 5.4 Installation All of the drivers required for operation (graphics, network, etc.) are also installed in this process. Panel PC 800 User's Manual V1.30...
5.6 Drivers Current drivers for all approved operating systems are available in the Downloads section of the B&R website www.br-automation.com. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
Codepages / User locales / Keyboards ✓ Disk Management Service Windows Installer Service ✓ ✓ Class Installer ✓ CoDevice Installer Media Player DirectX Accessories ✓ Number of fonts Table 201: Device functions in Windows XP Embedded with FP2007 Panel PC 800 User's Manual V1.30...
Panel 900 touch screen devices. The driver is available in the Downloads section of the B&R website (www.br- automation.com). Be sure to check that the "Enhanced Write Filter (EWF)" is enabled. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
✓ Terminal service ✓ Windows Firewall MSN Explorer Outlook Express ✓ Administrative Tools ✓ Remote Desktop Remote Assistance .NET Framework ASP.NET ✓ Local network bridge Table 203: Device functions in Windows Embedded Standard 2009 Panel PC 800 User's Manual V1.30...
Downloads section of the B&R website (www.br-automation.com). It is important that Enhanced Write Filter (EWF) is enabled for this. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
Microsoft OEM Windows Embedded Standard 7 64-bit, Service Pack 1, Language Pack DVD Table 204: 5SWWI7.0527-ENG, 5SWWI7.1527-ENG, 5SWWI7.0627-ENG, 5SWWI7.1627-ENG, 5SWWI7.0727-MUL, 5SWWI7.1727-MUL, 5SWWI7.0827-MUL, 5SWWI7.1827-MUL - Order data 64-bit versions are not supported by all systems. Panel PC 800 User's Manual V1.30...
Wenn der EWF (Enhanced Write Filter) verwendet werden soll, sind während des Setup oder SYSPREP alle Massenspeicher (außer dem Bootlaufwerk) aus dem System zu entfernen. It is also possible to disable additional mass storage devices in BIOS. Panel PC 800 User's Manual V1.30...
The driver is available in the Downloads section of the B&R website (www.br-automation.com). It is important that both the Enhanced Write Filter (EWF) and the File Based Write Filter (FBWF) are disabled for this. Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
Table 207: Windows CE 6.0 features The color depth depends on the display used. The "Compress Windows CE image" function in the B&R Embedded OS Installer can be used to reduce the image size. Panel PC 800 User's Manual V1.30...
CE installation. The B&R Embedded OS Installer is available in the Downloads section of the B&R website (www.br- automation.com). Additional information is available in the online help documentation for the B&R Embedded OS Installer. Panel PC 800 User's Manual V1.30...
System support is provided by ARwin with an AS 3.0.90 / AR 3.06 upgrade. An Automation Runtime dongle (USB interface button holder with Automation Runtime ARwin dongle) must be connected to run ARwin on a Panel PC 800, see "Order data" on page 250. Information: An Automation Runtime dongle is no longer required in AS 3.0.90 / AR 4.00.
• Reading software versions • Updating and backing up BIOS and firmware • Creating reports about the current system (support assistance) • Setting the SDL equalizer value when adjusting SDL cables • Changing the user serial ID Panel PC 800 User's Manual V1.30...
The ADI driver is already included in B&R images of embedded operating systems. If a more current ADI driver version exists (see the Downloads section of the B&R website), it can be installed later. It is important that Enhanced Write Filter (EWF) is disabled for this. Panel PC 800 User's Manual V1.30...
The optimal value for the cable length is defined by selecting "Use automatic setting". The equalizer value can only be changed if the function is supported by Automation Panel 900 (Panel firmware version 1.04 or higher). Panel PC 800 User's Manual V1.30...
Administrator rights are required in order to change the energy options or display the UPS status. 11.4.2 Displaying UPS default values 1. Open the Control Center in the Control Panel. 2. Select the UPS tab. Panel PC 800 User's Manual V1.30...
1. Open the Control Center in the Control Panel. 2. Select the UPS tab. 3. Under Battery settings, click on Edit. This opens the "Open" dialog box. 4. Select and open the file containing the battery settings. Panel PC 800 User's Manual V1.30...
• The UPS cannot be operated while the battery settings are being updated. • If the transfer is aborted, then the procedure must be repeated until the battery settings have been updated successfully. Otherwise, battery operation will no longer be possible. Panel PC 800 User's Manual V1.30...
• The UPS is automatically restarted after the UPS settings have been changed. This can cause a brief disruption in communication with the UPS. • Administrator rights are required in order to change the energy options or display the UPS status. Panel PC 800 User's Manual V1.30...
1.08 do not shut down automatically when the battery level is low. 11.4.7 Changing additional UPS settings 1. Open the Control Center in the Control Panel. 2. Select the UPS tab. 3. Under UPS settings, click on Advanced. This opens the following window: Panel PC 800 User's Manual V1.30...
Page 259
Regardless of these options, all changes to the UPS status are logged in the Windows event log (under "Application"). The Windows Messenger service is supported starting with B&R Windows Embedded version 2.20 and higher. Panel PC 800 User's Manual V1.30...
If power returns during the switch-off time, then the shutdown procedure is aborted. If power returns during the shutdown process, then the shutdown timer will run until the B&R Industrial PC enters standby mode, at which point the system will be rebooted. Panel PC 800 User's Manual V1.30...
• Automation PC 810 • Automation PC 820 • Automation PC 910 • Automation PC 2100 • Panel PC 300 • Panel PC 700 • Panel PC 800 • Panel PC 900 • Panel PC 2100 Panel PC 800 User's Manual V1.30...
Page 262
A detailed description of how to use ADI functions can be found in the help system. The B&R Automation Device Interface (ADI) development kit is available at no cost in the Downloads section of the B&R website (www.br-automation.com). Panel PC 800 User's Manual V1.30...
• Automation PC 910 • Automation PC 2100 • Panel PC 300 • Panel PC 700 • Panel PC 800 • Panel PC 900 • Panel PC 2100 • Power Panel 100/200 • Power Panel 300/400 Panel PC 800 User's Manual V1.30...
Page 264
B&R images of embedded operating systems. A detailed description of how to use ADI functions can be found in the help system. The ADI .NET SDK is available in the Downloads section of the B&R website (www.br-automation.com). Panel PC 800 User's Manual V1.30...
• Automation PC 510 • Automation PC 511 • Automation PC 620 • Automation PC 810 • Automation PC 820 • Automation PC 910 • Automation PC 2100 • Automation Panel 800 • Automation Panel 830 Panel PC 800 User's Manual V1.30...
Page 266
A detailed guide for configuring keys and LEDs can be found in the B&R Key Editor's help system. The B&R Key Editor is available at no cost in the Downloads section of the B&R website (www.br-automation.com). It can also be found on the B&R HMI Drivers & Utilities DVD (model number 5SWHMI.0000-00). Panel PC 800 User's Manual V1.30...
These devices satisfy the requirements of EC directive "2006/95/EC Low voltage directive" and are designed for the following areas: EN 61131-2:2007 Programmable logic controllers - Part 2: Equipment requirements and tests EN 60204-1:2006 + Safety of machinery - Electrical equipment of machines - Part 1: General require- A1:2009 ments Panel PC 800 User's Manual V1.30...
Canadian (CSA) standard in accordance with C22.2 No. 142-M1987 2.2 GOST-R Produkte mit dieser Kennzeichnung sind von einem akkreditierten Testlabor geprüft und dürfen in die Russische Föderation eingeführt werden (basierend auf der CEKon- formität). Panel PC 800 User's Manual V1.30...
Product ID 0AC201.91 4A0006.00-000 General information Storage time Max. 3 years at 30°C Certification cULus Electrical characteristics Capacity 950 mAh Self-discharging <1% per year (at 23°C) Voltage range Table 210: 0AC201.91, 4A0006.00-000 - Technical data Panel PC 800 User's Manual V1.30...
Page 270
Accessories • Replacement CMOS batteries Product ID 0AC201.91 4A0006.00-000 Environmental conditions Temperature Storage -20 to 60°C Relative humidity Operation 0 to 95% Storage 0 to 95% Transport 0 to 95% Table 210: 0AC201.91, 4A0006.00-000 - Technical data Panel PC 800 User's Manual V1.30...
Yes, although applies only if all components installed within the complete system have this certification Cage clamp terminal blocks cannot be used side-by-side. The limit data for each I/O module must be taken into consideration. Panel PC 800 User's Manual V1.30...
This adapter enables a standard monitor to be connected to the DVI-I interface. 3.3 Order data Model number Short description Figure Miscellaneous 5AC900.1000-00 DVI (male connector) to CRT (female connector) adapter. For connecting a standard monitor to a DVI-I interface. Table 213: 5AC900.1000-00 - Order data Panel PC 800 User's Manual V1.30...
Accessories • USB interface cover 4 USB interface cover 4.1 5AC900.1201-00 4.1.1 General information Flat front-side USB interface cover for Automation Panel 900, Power Panel 500, Panel PC 700 and Panel PC 800 devices. 4.1.2 Order data Model number Short description...
These replacement clamping blocks are used to mount B&R panel devices. 5.1.2 Order data Model number Short description Figure Accessories 5AC900.BLOC-00 Terminal block with brackets, 10 pcs.; replacement part Table 216: 5AC900.BLOC-00 - Order data Panel PC 800 User's Manual V1.30...
• A suitable system unit • Add-on UPS module 5AC600.UPSI-00 • Battery unit 5AC600.UPSB-00 • UPS connection cable 0.5 m (5CAUPS.0005-00) or 3 m (5CAUPS.0030-00) • Configuration of the B&R UPS in the ADI Control Center Panel PC 800 User's Manual V1.30...
Yes, although applies only if all components installed within the complete system have this certification 6.3.4 Installation This module is installed using the materials included in delivery. For more information regarding installation, see chapter 7 "Maintenance and service". Panel PC 800 User's Manual V1.30...
-65 to 80°C Transport -65 to 80°C Relative humidity Operation 5 to 95%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Altitude Operation Max. 3000 m Table 220: 5AC600.UPSB-00, 5AC600.UPSB-00 - Technical data Panel PC 800 User's Manual V1.30...
The following diagram shows the relationship between ambient temperature and service life. 50% reduction in service life expectancy when temperature increased by 8°C 33°C Ambient temperature [°C] 6.4.5 Deep discharge cycles 1000000 100000 10000 1000 Discharge depth [%] Figure 146: Deep discharge cycles Panel PC 800 User's Manual V1.30...
6.4.7 Drilling template Outline 178.9 170.5 141.9 38.9 126.5 Figure 148: 5PC600.UPSB-00 - Drilling template 6.4.8 Installation instructions Due to the unique construction of these batteries, they can be stored and operated in any position. Panel PC 800 User's Manual V1.30...
Fixed installation 5x wire cross section Weight Approx. 100 g Approx. 470 g Table 222: 5CAUPS.0005-00, 5CAUPS.0030-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
These 25 A fuses are replacement parts for the 5AC600.UPSB-00 battery unit (beginning with revision E0) as well as the 5AC600.UPSF-00 fuse kit. 6.7.2 Order data Model number Short description Figure Uninterruptible power supplies 5AC600.UPSF-01 UPS fuse, 5 pcs. Table 224: 5AC600.UPSF-01 - Order data Panel PC 800 User's Manual V1.30...
RS232 null modem cable, 1.8 m, for connecting UPS and IPC (9-pin female DSUB connector - 9-pin female DSUB connector) Optional accessories Replacement batteries Table 225: 9A0100.11, 9A0100.12, 9A0100.13, 9A0100.14, 9A0100.15, 9A0100.16, 9A0100.17 - Order data Panel PC 800 User's Manual V1.30...
Page 284
UPS batteries type B (replacement part), 2x 12 V, 2.2 Ah, for battery unit 9A0100.14 9A0100.17 UPS batteries type C (replacement part), 2x 12 V, 4.5 Ah, for battery unit 9A0100.16 Table 225: 9A0100.11, 9A0100.12, 9A0100.13, 9A0100.14, 9A0100.15, 9A0100.16, 9A0100.17 - Order data Panel PC 800 User's Manual V1.30...
8.1.3 Technical data Product ID 5ACPCI.ETH1-01 General information B&R ID code 0xA58A Diagnostics Data transfer Yes, using status LED Certification cULus cULus HazLoc Class 1 Division 2 GOST-R Table 227: 5ACPCI.ETH1-01 - Technical data Panel PC 800 User's Manual V1.30...
(Windows XP Professional, Windows XP Embedded and MS-DOS) are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
8.2.3 Technical data Product ID 5ACPCI.ETH3-01 General information B&R ID code 0xA58B Diagnostics Data transfer Yes, using status LED Certification cULus cULus HazLoc Class 1 Division 2 GOST-R Table 230: 5ACPCI.ETH3-01 - Technical data Panel PC 800 User's Manual V1.30...
(Windows XP Professional, Windows XP Embedded and MS-DOS) are available in the Downloads section of the B&R website (www.br-automation.com). Information: Required drivers can only be downloaded from the B&R website, not from manufacturer websites. Panel PC 800 User's Manual V1.30...
Self-Monitoring, Analysis and Reporting Technology (S.M.A.R.T.) is an industry standard for mass storage devices that has been introduced to monitor important parameters and quickly detect imminent failures. Critical performance and calibration data is monitored and stored in order to help predict the probability of errors. Panel PC 800 User's Manual V1.30...
Accessories • CompactFlash cards 9.2.5 Maximum reliability CompactFlash cards used by B&R use SLC flash blocks and static wear leveling together with a powerful ECC algorithm to provide maximum reliability. Panel PC 800 User's Manual V1.30...
Page 296
Yes, although applies only if all components installed within the complete system have this certification Endurance of B&R CFs (with linear written block size ≥128 kB). Not supported by the B&R Embedded OS Installer. Panel PC 800 User's Manual V1.30...
Page 300
Speed specification with 1X = 150 Kb/s. All specifications refer to Samsung flash chips, CompactFlash cards in UDMA mode 4 and 30 ns cycle time in True IDE mode with sequential write/read test. Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
2 GB 4 GB 8 GB Data retention 10 years Data reliability <1 unrecoverable error in 10 bit read accesses Lifetime monitoring Table 239: 5CFCRD.0064-03, 5CFCRD.0128-03, 5CFCRD.0256-03, 5CFCRD.0512-03, 5CFCRD.1024-03, 5CFCRD.2048-03, 5CFCRD.4096-03, 5CFCRD.8192-03 - Technical data Panel PC 800 User's Manual V1.30...
Page 304
Table 239: 5CFCRD.0064-03, 5CFCRD.0128-03, 5CFCRD.0256-03, 5CFCRD.0512-03, 5CFCRD.1024-03, 5CFCRD.2048-03, 5CFCRD.4096-03, 5CFCRD.8192-03 - Technical data Yes, although applies only if all components installed within the complete system have this certification Not supported by the B&R Embedded OS Installer. Panel PC 800 User's Manual V1.30...
The problem described can occur because the startup time for the CompactFlash cards fluctuates due to the different components being used. Depending on the CompactFlash card being used, this error might never, sometimes or always occur. Panel PC 800 User's Manual V1.30...
Operating systems Windows XP Professional Windows XP Embedded Windows ME Windows 2000 Windows CE 5.0 Windows CE 4.2 Electrical characteristics Power consumption 650 µA sleep mode, 150 mA read/write Table 241: 5MMUSB.2048-00 - Technical data Panel PC 800 User's Manual V1.30...
Width 19 mm Length 52.2 mm Height 7.9 mm Table 241: 5MMUSB.2048-00 - Technical data Indicates data being transferred (sending and receiving). 10.1.4 Temperature/Humidity diagram Operation Temperature [°C] Figure 164: 5MMUSB.2048-00 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
Windows XP Professional Windows XP Embedded Windows ME Windows 2000 Windows CE 5.0 Windows CE 4.2 Electrical characteristics Power consumption Max. 500 µA sleep mode, max. 120 mA read/write Table 243: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data Panel PC 800 User's Manual V1.30...
Length 67.85 mm Height 8.35 mm Table 243: 5MMUSB.2048-01, 5MMUSB.4096-01 - Technical data Indicates data being transferred (sending and receiving). 10.2.4 Temperature/Humidity diagram Storage Operation Transport Temperature [°C] Figure 165: 5MMUSB.xxxx-01 - Temperature/Humidity diagram Panel PC 800 User's Manual V1.30...
USB A interface slot Figure 166: 5MD900.USB2-02 - Interfaces 11.1.4 Technical data Product ID 5MD900.USB2-02 General information Max. cable length 5 m (not including hub) Certification cULus GOST-R Table 245: 5MD900.USB2-02 - Technical data Panel PC 800 User's Manual V1.30...
Page 312
10 to 100 Hz: 2 g (19.6 m/s² 0-peak) Transport 10 to 100 Hz: 2 g (19.6 m/s² 0-peak) Shock Operation 5 g, 11 ms Storage 60 g, 11 ms Transport 60 g, 11 ms Table 245: 5MD900.USB2-02 - Technical data Panel PC 800 User's Manual V1.30...
Temperature specifications refer to operation at 500 meters. The maximum ambient temperature is typically derated by 1°C per 1000 meters (starting at 500 meters above sea level). 11.1.5 Dimensions Figure 167: 5MD900.USB2-02 - Dimensions 11.1.6 Dimensions with front cover Figure 168: USB media drive with front cover - Dimensions Panel PC 800 User's Manual V1.30...
The USB media drive can be operated as a desktop device (rubber feet) or as a rack-mounted device (2 mounting rail brackets included). 11.1.9.1 Mounting orientation Less than 20° Less than 20° Less than 20° Less than 20° Figure 170: 5MD900.USB2-02 - Mounting orientation Panel PC 800 User's Manual V1.30...
Table 248: 5A5003.03 - Technical data 11.2.4 Dimensions Figure 171: 5A5003.03 - Dimensions 11.2.5 Contents of delivery Quantity Component Front cover 5A5003.03 for the USB media drive M3 locknut Cover retaining clip Table 249: 5A5003.03 - Contents of delivery Panel PC 800 User's Manual V1.30...
• Automation PC 620 / Panel PC 700 CPU board 945GME N270 BIOS • Automation PC 680 • Automation PC 810 / Automation PC 820 / Panel PC 800 B945GME BIOS • Automation PC 810 / Panel PC 800 945GME N270 CPU board BIOS •...
Page 318
• Power Panel 300/400 (aPCI) • Power Panel 300/400 (MTCX) • Power Panel 500 / Automation PC 510 / Automation PC 511 (MTCX, SDLR, I/O board) • Panel PC 800 (MTCX, SDLR, SDLT) • UPS firmware Utilities/Tools • B&R Embedded OS Installer •...
Page 319
• Acrobat Reader 5.0.5 (freeware in German, English and French) • Power Archiver 6.0 (freeware in German, English and French) • Internet Explorer 5.0 (German and English) • Internet Explorer 6.0 (German and English) Panel PC 800 User's Manual V1.30...
≥5x cable diameter (male connector - ferrite bead and ferrite bead - ferrite bead) Weight Approx. 260 g Approx. 460 g Approx. 790 g Table 252: 5CADVI.0018-00, 5CADVI.0050-00, 5CADVI.0100-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
Page 322
If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. DVI-D (24+1), male DVI-D (24+1), male Pinout DVI-D (24+1), male DVI-D (24+1), male Cable shield Cable shield Figure 176: 5CADVI.0xxx-00 - Pinout Panel PC 800 User's Manual V1.30...
Approx. 1500 g Approx. 2250 g Approx. 2880 g Approx. 4800 g Approx. 5520 g Table 254: 5CASDL.0018-00, 5CASDL.0050-00, 5CASDL.0100-00, 5CASDL.0150-00, 5CASDL.0200-00, 5CASDL.0250-00, 5CASDL.0300-00 - Technical data Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
Page 325
If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 179: 5CASDL.0xxx-00 - Pinout Panel PC 800 User's Manual V1.30...
Approx. 300 g Approx. 590 g Approx. 2800 g Approx. 2860 g Table 256: 5CASDL.0018-01, 5CASDL.0050-01, 5CASDL.0100-01, 5CASDL.0150-01 - Technical data Yes, although applies only if all components installed within the complete system have this certification Panel PC 800 User's Manual V1.30...
Page 328
If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 182: 5CASDL.0xxx-01 - Pinout Panel PC 800 User's Manual V1.30...
UL AWM 20236 80°C 30 V Flame-resistant In accordance with UL758 (cable vertical flame test) Oil and hydrolysis resistance In accordance with VDE 0282-10 Table 258: 5CASDL.0018-03, 5CASDL.0050-03, 5CASDL.0100-03, 5CASDL.0150-03, 5CASDL.0200-03, 5CASDL.0250-03, 5CASDL.0300-03 - Technical data Panel PC 800 User's Manual V1.30...
Oil and hydrolysis resistance In accordance with VDE 0282-10 Environmental conditions Temperature Storage -20 to 60°C Fixed installation -20 to 60°C Flexible installation -5 to 60°C Table 261: 5CASDL.0300-13, 5CASDL.0400-13, 5CASDL.0430-13 - Technical data Panel PC 800 User's Manual V1.30...
Page 334
If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. DVI (24+1), male DVI (24+1), male Pinout DVI (24+1), male DVI (24+1), male Cable shield Cable shield Figure 188: 5CASDL.0xx0-13 - Pinout Panel PC 800 User's Manual V1.30...
Page 335
SDL flex cables with an extender must be connected between the B&R Industrial PC and the Automation Panel display unit in the correct direction. The proper signal direction is indicated on the extender. B&R Industrial PC Figure 189: Example of the signal direction for an SDL flex cable with extender Panel PC 800 User's Manual V1.30...
If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. Pinout USB Type A, male USB Type B, male Jacket Jacket Figure 190: 5CAUSB.00xx-00 USB cables - Pinout Panel PC 800 User's Manual V1.30...
Max. 0.5 Nm Mechanical characteristics Dimensions Length 1.8 m ±50 mm 5 m ±80 mm 10 m ±100 mm Diameter Max. 5 mm Flex radius Min. 70 mm Table 265: 9A0014.02, 9A0014.05, 9A0014.10 - Technical data Panel PC 800 User's Manual V1.30...
Page 338
If a self-made cable is used, B&R cannot guarantee that it will function properly. All cables provided by B&R are guaranteed to function properly, however. 9-pin male DSUB 9-pin female DSUB Pinout 9-pin male DSUB 9-pin female DSUB Jacket Jacket Figure 191: 9A0014.xx RS232 cables - Pinout Panel PC 800 User's Manual V1.30...
• Touch the housing or ground connection in order to discharge any electrostatic charge from your body. • Remove the cover from the battery compartment and carefully pull out the battery using the removal strip. Panel PC 800 User's Manual V1.30...
Page 341
• Reconnect the power supply to the B&R Industrial PC (plug in the power cable). • Reset the date and time in BIOS. Warning! Lithium batteries are considered hazardous waste. Used batteries should be disposed of in accordance with applicable local regulations. Panel PC 800 User's Manual V1.30...
(ethanol). The cleaning agent should be applied to the cloth beforehand, not sprayed directly on the device! Aggressive solvents, chemicals, scouring agents, pressurized air or steam jets should never be used. Information: Displays with a touch screen should be cleaned regularly. Panel PC 800 User's Manual V1.30...
Power must be turned off before replacing CompactFlash cards. The CompactFlash card can be replaced quickly and easily by pressing the ejector (see image) with a pointed object such as a pen. Ejector CompactFlash Figure 195: CompactFlash + ejector Panel PC 800 User's Manual V1.30...
1. Loosen and remove the two quick release screws on the protective cover / slide-in compact drive. Figure 196: Loosening the quick release screws 2. Insert the compact SATA drive and tighten the quick release screws. Figure 197: Inserting the compact SATA drive Panel PC 800 User's Manual V1.30...
3. Remove the dummy slide-in module or slide-in drive by unscrewing the two quick release screws. Figure 198: Loosening the quick release screws 4. Insert the slide-in drive and tighten with the two ¼ turn screws. Figure 199: Installing the slide-in drive Panel PC 800 User's Manual V1.30...
4. Insert the slide-in compact adapter and tighten the two quick release screws. Figure 201: Installing the slide-in compact adapter 5. Once the adapter has been installed, the slide-in compact drive can be inserted. Panel PC 800 User's Manual V1.30...
Page 347
Maintenance and service • Installing the slide-in compact adapter Figure 202: Inserting the slide-in compact drive Panel PC 800 User's Manual V1.30...
Fan kit cover Filter clasp Dust filter Figure 205: Securing the dust filter with the filter clasp 4. Place the fan kit cover in the housing and fasten using the Torx screws removed earlier. Panel PC 800 User's Manual V1.30...
Page 349
Maintenance and service • Installing and replacing fan kits Information: The dust filter should be checked regularly depending on the area of use and degree of contamination. Panel PC 800 User's Manual V1.30...
3. Attach the UPS isolation to the bottom/rear of the UPS module and install both using 2 Torx screws (T10) on the housing and 1 Torx screw (T10) on the mainboard (spacer bolt). Use the previously removed Torx screws and the Torx screws from the installation material. Figure 208: Installing the UPS module Panel PC 800 User's Manual V1.30...
Page 351
4. Attach the connection cable (see marked female connector). Figure 209: Attaching the connection cable Information: When connecting the cable, make sure that the connector locks into place. Figure 210: Connector locking mechanism 5. Attach the side cover. Panel PC 800 User's Manual V1.30...
Figure 211: Removing the cover for the battery unit 3. To install the fuse, the red cable must be disconnected from the battery circuit board. Figure 212: Disconnecting the cable Panel PC 800 User's Manual V1.30...
Page 353
6. The cover for the battery unit can now be reattached. Insert the clips on the cover into the notch on the battery unit and tighten down the cover with the Torx screws removed previously. 7. Reconnect the 5AC600.UPSB-00 battery unit to the B&R Industrial PC. Panel PC 800 User's Manual V1.30...
Bus units can be installed and replaced in system units with 1 card slot or in expansions with 2 card slots. 10.1 Procedure 1. Disconnect the power supply to the Panel PC 800. 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body.
Figure 217: Removing the screws 2. Place the adapter and guide rails in the intended positions and fasten them using the Torx screws (T10) removed earlier. Figure 218: Installing the 5AC803.BC01-00 adapter 3. Attach the side cover. Panel PC 800 User's Manual V1.30...
Maintenance and service • Installing and replacing adapters 11.2 Procedure for the 5AC803.BC02-00 adapter 1. Insert the adapter into the intended slot. Figure 219: Installing the 5AC803.BC02-00 adapter 2. Attach the side cover. Panel PC 800 User's Manual V1.30...
1. Loosen the quick release screws and remove the PCIec module cover. Figure 220: Removing the PCIec module cover 2. Slide the PCIec plug-in card into place. Figure 221: Inserting the PCIec plug-in card 3. Fasten the PCIec plug-in card using the quick release screws. Panel PC 800 User's Manual V1.30...
13.1 PPC800 without expansion 1. Disconnect the power supply to the Panel PC 800. 2. Touch the housing or ground connection in order to discharge any electrostatic charge from your body. 3. Loosen the indicated combi-Torx screws (T10).
6. On the front side, slide the hard disk down and away (Replacing the hard disk - left image). 7. Insert the new hard disk carefully into the connector (Replacing the hard disk - right image), being careful to only touch it on the front, not on the top. Panel PC 800 User's Manual V1.30...
Page 360
10.An error message is output by the RAID BIOS after starting the system: "RAID1 set is in Rebuild status. The rebuild will continue after boot sequence is complete". 11. A rebuild can be performed immediately in SATA RAID BIOS or once the PC has booted - see "Rebuild mirrored set" on page 179. Panel PC 800 User's Manual V1.30...
The MTCX constantly monitors the temperature using temperature sensors, which directly determines how the fans are controlled. The speed depends on the measured temperature. The limit values depend on the MTCX firmware version being used. Available in the Downloads section of the B&R website (www.br-automation.com). Panel PC 800 User's Manual V1.30...
Page 362
For example, slide-in 1: 44°C + 16°C = 60°C --> Maximum fan speed The fans will only be shut off again if the evaluation temperature is more than 6°C below the switch-on temperature for a period of 30 minutes (=overshoot time). Panel PC 800 User's Manual V1.30...
Connector for external devices Assignment Power 4-pin connector, male +12 VDC Max. 10 watts Max. 5 watts +5 VDC Table 271: Connector on the mainboard - Pinout Connections are protected with a 1 A multi-fuse. Panel PC 800 User's Manual V1.30...
Figure 228: 5-wire AMT touch screen - Temperature/Humidity diagram 3.3 Cleaning Danger! This device can only be cleaned when switched off in order to prevent unintended functions from being triggered when handling the touch screen or pressing keys. Panel PC 800 User's Manual V1.30...
Page 365
(ethanol). The cleaning agent should be applied to the cloth beforehand, not sprayed directly on the device! Aggressive solvents, chemicals, scouring agents, pressurized air or steam jets should never be used. Information: Displays with a touch screen should be cleaned regularly. Panel PC 800 User's Manual V1.30...
Sea water Decon Table 273: Chemical resistance of the panel overlay The panel overlay conforms to DIN 42115 section 2 for exposure to glacial acetic acid for less than one hour without visible damage. Panel PC 800 User's Manual V1.30...
Appendix A • Viewing angles 5 Viewing angles Viewing angle specifications (R, L, U, D) for the display types are listed in the technical data for each device. Facing 6 o'clock Panel PC 800 User's Manual V1.30...
6 Mounting compatibility This section describes the compatibility of the installation dimensions for Power Panel 100/200, Power Panel 300/400, Power Panel 500, Automation Panel 900, Automation Panel 700 and Panel PC 800 devices according to device display size. The outer dimensions of the device types are identical for the respective display sizes.
Outer contour of device Cutout for device Figure 230: Mounting compatibility - 5.7" device - Horizontal1 5.7" Power Panel 500 devices and Power Panel 100/200/300/400 devices are 100% mounting compatible in the Horizontal1 format. Panel PC 800 User's Manual V1.30...
Page 370
• When mounting, make sure that the PP100/200/300/400 devices are placed and mounted as close to the center of the cutout as possible. Failure to do so can prevent the retaining clips from holding firmly, which means that a firm seal is no longer guaranteed with the gasket (IP65). Panel PC 800 User's Manual V1.30...
• When mounting, make sure that the PP100/200/300/400 devices are placed and mounted as close to the center of the cutout as possible. Failure to do so can prevent the retaining clips from holding firmly, which means that a firm seal is no longer guaranteed with the gasket (IP65). Panel PC 800 User's Manual V1.30...
15" Power Panel 500 devices are not 100% mounting compatible with Power Panel 100/200/300/400, Automation Panel 900, Panel PC 700 and Panel PC 800 devices in the Vertical1 format. The Power Panel 500 devices require a cutout that is 0.5 mm higher (top and bottom edge).
Outer contour of device Cutout for device Figure 240: Mounting compatibility - 19" device - Horizontal1 19" Automation Panel 900, Panel PC 700 and Panel PC 800 are 100% mounting compatible in the Horizontal1 format. Panel PC 800 User's Manual V1.30...
The cause of the failure may be load related or age-related, and therefore a random failure, or related to a flaw inherent in the system. In this case, it is known as a systematic failure. Panel PC 800 User's Manual V1.30...
Page 377
Figure 53: 5AC801.DVRS-00 - Temperature humidity diagram............128 Figure 54: PCI SATA RAID controller....................129 Figure 55: 5ACPCI.RAIC-03 - Temperature humidity diagram.............131 Figure 56: 5ACPCI.RAIC-04 - Temperature humidity diagram.............133 Figure 57: PCI SATA RAID controller....................134 Panel PC 800 User's Manual V1.30...
Page 379
5MMUSB.xxxx-01 - Temperature/Humidity diagram............310 Figure 167: 5MD900.USB2-02 - Interfaces.....................311 Figure 168: 5MD900.USB2-02 - Dimensions..................313 Figure 169: USB media drive with front cover - Dimensions..............313 Figure 170: USB media drive with front cover - Installation cutout............314 Panel PC 800 User's Manual V1.30...
Page 380
Installing the side cover on a PPC800 with an expansion (1-slot expansion shown in image) 358 Figure 225: Screw layout on the back side of the 5ACPCI.RAIC-03 SATA RAID controller....359 Figure 226: Replacing the hard disk.......................360 Figure 227: MTCX controller location..................... 361 Panel PC 800 User's Manual V1.30...
Page 391
Cables................................. 320 DVI.................................. 320 SDL................................. 323 SDL flex................................329 SDL flex cable with extender......................... 332 SDL with 45° male connector........................326 USB................................336 Card slot................................52 CE mark................................267 Certifications............................... 268 certifications GOST-R................................268 Certifications Panel PC 800 User's Manual V1.30...
Page 392
Electromagnetic compatibility..........................267 Embedded OS Installer............................234 EMC directive..............................267 ESD..................................16 Electrical components with a housing......................16 Electrical components without a housing......................16 Individual components............................16 Packaging................................. 16 Proper handling..............................16 ETH1..................................45 Ethernet................................. 45 Panel PC 800 User's Manual V1.30...
Page 393
Installing and replacing slide-in drives....................... 345 Installing the side cover............................. 358 Installing the slide-in compact adapter....................... 346 Installing the UPS fuse kit..........................352 Installing the UPS module..........................350 Interfaces................................41 Interrupt assignment............................224 Key Editor................................265 Panel PC 800 User's Manual V1.30...
Page 394
System failure error codes..........................83 power supply..............................41, 156 PPC800 15" Cutout................................58 Dimensions............................... 58 Interfaces................................55 Power calculation............................. 34 Technical data..............................55 PPC800 19" Cutout................................64 Dimensions............................... 64 Interfaces................................61 Power calculation............................. 35 Panel PC 800 User's Manual V1.30...
Page 395
Temperature monitoring - Fan control....................... 361 Temperature sensor positions..........................31 Temperature specifications........................... 28 temperature testing............................. 157 Temperature testing instructions........................157 Temperature testing procedure.......................... 157 Touch screen calibration............................. 172 UL certification..............................268 Uninterruptible power supply..........................275 Panel PC 800 User's Manual V1.30...
Page 396
Viewing angles..............................367 WES2009................................243 WES7.................................. 246 Windows 7................................238 Windows CE............................... 248 Windows CE 6.0 features..........................248 Windows Embedded Standard 2009........................243 Windows Embedded Standard 7........................245 Windows XP Embedded............................. 241 Windows XP Professional..........................236 Panel PC 800 User's Manual V1.30...