Ul Haz. Loc. Certification; General Safety Guidelines; Mounting And Installation - B&R Panel PC 2100 User Manual

Hide thumbs Also See for Panel PC 2100:
Table of Contents

Advertisement

Standards and certifications
Model number
Description
5CFAST.4096-00
CFast card, 4 GB SLC
5CFAST.8192-00
CFast card, 8 GB SLC
5CFAST.016G-00
CFast card, 16 GB SLC
5CFAST.032G-00
CFast card, 32 GB SLC
5CFAST.032G-10
CFast card, 32 GB MLC
5CFAST.064G-10
CFast card, 64 GB MLC
5CFAST.128G-10
CFast card, 128 GB MLC
5CFAST.256G-10
CFast card, 256 GB MLC
5ACCIF01.FPCC-000 Interface card - 2x CAN interfaces - 1x X2X Link interface - 1x POWERLINK interface - 512 kB nvSRAM - For APC2100/
PPC2100
5ACCIF01.FPLS-000
Interface card - 1x RS232 interface - 1x POWERLINK interface - 32 kB FRAM - For APC2100/PPC2100 - Only available
with a new device
5ACCIF01.FPSC-000
Interface card - 1x RS232 interface - 1x CAN interface - 1x POWERLINK interface - 32 kB FRAM - For APC2100/PPC2100
- Only available with a new device
0TB103.9
Connector 24 VDC - 3-pin female - Screw clamp terminal block 3.31 mm²
0TB103.91
Connector 24 VDC - 3-pin female - Cage clamp terminal block 3.31 mm²
0TB1210.3100
Connector 300 VDC - 10-pin female - Cage clamp terminal block - Protected against vibration by the screw flange
DNV GL certificates with specifications for permitted environmental conditions are available on the B&R website
at
Downloads - Certificates - Maritime - DNV
Certificates for compass safe distance are available at

5.2.7 UL Haz. Loc. certification

Ind.Cont.Eq.
for Haz.Locs.
Cl. I, Div. 2,
Groups ABCD
E180196 (T4)

5.2.7.1 General safety guidelines

PPC2100 systems with AP923 or AP1000 panels that are certified for use in potentially explosive environments
and carry the marking above are suitable for use in Class 1, Division 2, Groups A, B, C and D or in nonexplosive
environments and correspond to the following standards: UL 508 - 17th Edition, ANSI/ISA 12.12.01:2013, CSA
C22.2 No. 213-M1987, and CSA C22.2 No. 157-92 (R2012).

5.2.7.2 Mounting and installation

Devices with explosion protection are to be used as intended and are only permitted to be operated by knowledge-
able and qualified personnel according to these operating instructions and the other information contained in the
corresponding user's manual. Operation in any other way endangers the safety and functionality of the devices
and the connected systems. The operator is responsible for following all applicable safety and accident prevention
regulations, as well as adhering to standards.
Devices must be installed in a suitable protective housing that can only be opened by using a tool. In order to
guarantee sufficient air circulation, allow the specified amount of space around the device. Use only in environments
with pollution degree 2. The maximum ambient temperature varies depending on the individual components being
used, see section
"Temperature specifications" on page
The certification marking on the device must be checked before each installation or use of the device in potentially
explosive environments. Additional equipment must be suitable for the operating location. Final assembly must be
approved by the relevant local authorities. Wiring must follow national regulations and meet all legal requirements.
Devices must remain voltage-free until installation work is complete. The tightening torque for the power supply
terminals is 0.5 Nm. Cables must be able to handle a surface temperature of 75°C. PPC2100 systems with AP923
or AP1000 panels are only permitted to be operated with 24 VDC.
306
GL.
Products with this mark are tested by Underwriters Laboratories and listed as "indus-
trial control equipment for use in hazardous locations". This mark is valid for the USA
and Canada and simplifies the certification of your machines and manufacturing sys-
tems in this economic region.
Underwriters Laboratories (UL) per standard ANSI/ISA 12.12.01
Canadian (CSA) standard per C22.2 No. 213-16
UL HazLoc certificates are available on the B&R website under
cates -
HazLoc.
Downloads - Certificates - Maritime - Compass safe
32.
DNV GL
beginning
with rev.
D0
D0
D0
D0
D0
D0
D0
C0
C0
D0
D0
D0
D0
D0
distance.
Downloads - Certifi-
Panel PC 2100 user's manual V1.17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mappc2100-eng

Table of Contents