Model number
Controller
nvSRAM
Size
Data retention
Read/Write endurance
Remanent variables in power failure mode
Interfaces
POWERLINK
Quantity
Transfer
Type
Design
Transfer rate
Cable length
CAN
Quantity
Design
Transfer rate
Terminating resistor
Type
X2X
Type
Quantity
Design
Electrical characteristics
Power consumption
Operating conditions
Pollution degree per EN 61131-2
Environmental conditions
Temperature
Operation
Storage
Transport
Relative humidity
Operation
Storage
Transport
Mechanical characteristics
Weight
1)
Yes, although applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)
Yes, although applies only if all components installed in the complete system have this certification and are listed on the associated DNV GL certificate for
the product family.
3)
For more information, see Automation Help (Communication - POWERLINK - General information - Hardware - IF / LS).
4)
CAN1: Electrically isolated.
CAN2: Not electrically isolated
5)
The terminating resistor can only be enabled/disabled for the CAN1 interface.
2.3.5.1.3.1 POWERLINK interface - Pinout
The POWERLINK interface on the system unit is referred to as IF1.
Wiring
Cable length
Status LED
Green
Link LED
Yellow
Link (POWERLINK net-
work connection available)
1)
The interfaces, etc. available on the device or module have been numbered as such for the purpose of clear differentiation. This numbering may deviate
from the numbering used by the respective operating system, however.
2)
This interface is referred to as IF1 in Automation Studio / Automation Runtime.
Panel PC 2100 user's manual V1.17
Table 113: 5ACCIF01.FPCC-000 - Technical data
POWERLINK - IF1
S/STP (Cat 5e)
Max. 100 m (min. Cat 5e)
On
Off
See Status/Error LED.
On
Off
Activity (blinks to indi-
cate active data transfer)
Table 114: 5ACCIF01.FPCC-000 - POWERLINK interface
5ACCIF01.FPCC-000
512 kB
20 years
Min. 1,000,000
256 kB
(e.g. for Automation Runtime, see Automation Help)
1
100BASE-TX
Type 4
3)
Shielded RJ45
100 Mbit/s
Max. 100 m between two stations (segment length)
2
10-pin, male
4)
Max. 1 Mbit/s
Can be enabled or disabled using a slide switch
X2X Link master
1
10-pin, male, electrically isolated
2 W
Pollution degree 2
-20 to 55°C
-20 to 60°C
-20 to 60°C
5 to 90%, non-condensing
5 to 95%, non-condensing
5 to 95%, non-condensing
25 g
1)2)
1
LED "Link"
Technical data
5)
RJ45, female
LED "Status"