Installation Diagrams - B&R Panel PC 2100 User Manual

Hide thumbs Also See for Panel PC 2100:
Table of Contents

Advertisement

Technical data

2.2.1.2 Installation diagrams

Information:
When installing the Panel PC 2100, be sure to leave sufficient space for air circulation as well as addi-
tional space for operation and maintenance of the device.
AP9x3 panels - Installation diagrams
Figure 5: Panel PC 2100 with AP9x3 panels (sample figure) - Installation diagram
All dimensions are specified in mm.
The cutout tolerances are +0 mm / -0.5 mm.
Display type
12.1" single-touch
15.0" single-touch
19.0" single-touch
15.6" multi-touch
18.5" multi-touch
21.5" multi-touch
24.0" multi-touch
Dimension "Z" describes the thickness of the wall or control cabinet panel.
A hex screwdriver is needed to tighten and remove the screws on the retaining clips. The maximum tightening
torque of the retaining clips is 1 Nm.
26
X
Model number
5AP923.1215-00
5AP923.1505-00
5AP923.1906-00
5AP933.156B-00
5AP933.185B-00
5AP933.215C-00
5AP933.240C-00
Table 12: AP9x3 panels - Installation diagrams
X
Y
Z min.
Z max.
304
228
1
6
359
277
1
6
429
347
1
6
403
247.5
1
6
464
284
1
6
530.5
322
1
6
587.5
353
1
6
Z
Number of retaining clips
10 pcs.
10 pcs.
12 pcs.
10 pcs.
10 pcs.
14 pcs.
14 pcs.
Panel PC 2100 user's manual V1.17