B&R Panel PC 2100 User Manual page 36

Hide thumbs Also See for Panel PC 2100:
Table of Contents

Advertisement

Technical data
2.2.2.1.4 How to determine the maximum, minimum and typical ambient temperatures
1. Select the system unit.
2. Rows "Maximum, minimum ambient temperature for worst-case operation" and "Maximum ambient temper-
ature for typical operation" show the minimum, maximum and typical ambient temperatures for the complete
system in connection with the respective system unit.
Information:
The maximum and typical temperature values correspond to operation at 500 meters above sea
level. The maximum/typical ambient temperature is typically derated by 1°C per 1000 meters (start-
ing at 500 meters above sea level).
3. If additional interface options and CFast cards are installed, these components can change the temperature
limits of the PPC2100 system.
4. Limitations are possible due to the mounting orientation of the Panel PC 2100. For more information, see
section
"Mounting orientations" on page
5.
"Information regarding typical conditions" on page 35
atures. Testing and evaluation in this regard must be performed on-site by the user in each individual case
(temperatures can be read in BIOS or using the B&R Control Center).
If the installed component is marked by a "✓", it can be operated at the minimum/maximum/typical ambient tem-
perature of the complete system without problems.
If a temperature value is specified for the installed component, for example "45", then the ambient temperature of
the complete PPC2100 system is not permitted to exceed this temperature.
36
30.
must be taken into account for typical ambient temper-
Panel PC 2100 user's manual V1.17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mappc2100-eng