Automation Runtime; General Information; Order Data; Automation Runtime Windows (Arwin) - B&R Panel PC 2100 User Manual

Hide thumbs Also See for Panel PC 2100:
Table of Contents

Advertisement

Software

4.9 Automation Runtime

4.9.1 General information

An integral component of Automation Studio is the Automation Runtime real-time operating system. This real-time
operating system is the software kernel that allows applications to run on a target system.
• Guaranteed highest possible performance for the hardware being used
• Runs on all B&R target systems
• Makes the application hardware-independent
• Easy portability of applications between B&R target systems
• Deterministic behavior guaranteed by cyclic system
• Configurable jitter tolerance in all task classes
• Supports all relevant programming language such as IEC 61131-3 and C
• Extensive function library conforming to IEC 61131-3 as well as the expanded B&R Automation library
• Integrated into Automation NET. Access to all networks and bus systems via function calls or the Automation
Studio™ configuration
B&R Automation Runtime is fully embedded in the corresponding target system (the hardware where Automation
Runtime is installed). It allows application programs to access I/O systems (e.g. via the fieldbus) and other devices
(interfaces, networks, etc.).

4.9.2 Order data

Model number
Short description
Technology Guard
0TG1000.01
Technology Guard (MSD)
0TG1000.02
Technology Guard (HID)
1TG4600.10-5
Automation Runtime Windows TG license
1TG4601.06-5
Automation Runtime Embedded TG license
1TG4601.06-T
Automation Runtime Embedded Terminal TG license
Table 269: 0TG1000.01, 0TG1000.02, 1TG4600.10-5, 1TG4601.06-5, 1TG4601.06-T - Order data

4.9.3 Automation Runtime Windows (ARwin)

System requirements
The following software versions (or higher) are required to operate Automation Runtime Windows on a Panel PC
2100:
• ARwin upgrade AR C4.10
• ARwin upgrade AR N4.10 for 5PPC2100.BY48-000
• Automation Studio V4.1.4.0
• Technology Guard
Information:
In order to operate Automation Runtime Windows (ARwin), BIOS setting Advanced - Miscellaneous
configuration - Realtime environment must be set to Enabled.
Information:
In order to slightly improve the real-time behavior (jitter) of Automation Runtime Windows (ARwin) in
graphics-intensive applications, set BIOS setting Advanced - Graphics (IGD) configuration - IGD turbo
to Disabled.
Important: If BIOS setting Advanced - Graphics (IGD) configuration - IGD turbo is set to Disabled, the
graphics performance of the system is noticeably reduced.