1-2. ADDRESS SETTING

For this system, each address should be preset before operation.
Please refer following table for outdoor unit, indoor unit, RB unit and each remote controller.
„ KINDS OF ADDRESS AND SETTING RANGE
UNIT
SETTING
Refrigerant
A
circuit address
Outdoor unit
B
address *1
Outdoor unit
Number of slave
C
unit *1
Number of
L
outdoor units
installed *1
Terminal
resistor
Refrigerant
D
circuit address
Indoor unit
Indoor unit
E
address
Remote
F
controller
address
*Set up after confirming the details of each unit.
*1: This function is available VR-II, V-II and V-III series
SETTING
TYPE OF SWITCH
RANGE
Setting
00 ~ 99
example
01
0 ~ 2
0 ~ 2
1 ~ 3
ON/OFF
n Manual address setting
Setting
example
REF AD
01
n Wireless R.C
Set this switch to 00 at factory setting.
n Wired R.C. (3-wire type)
00 ~ 99
Set this switch to 00 at factory setting.
n Simple R.C.
Set this switch to 00 at factory setting.
n Wired R.C. (2-wire type)
Set this switch to 00 at factory setting.
n Automatic address setting
Set this switch to 00 at factory setting.
n Manual address setting
Setting
example
IU AD
12
n Wireless R.C
Set this switch to 00 at factory setting.
n Wired R.C. (3-wire type)
00 ~ 63
Set this switch to 00 at factory setting.
n Simple R.C.
Set this switch to 00 at factory setting.
n Wired R.C. (2-wire type)
Set this switch to 00 at factory setting.
n Automatic address setting
Set this switch to 00 at factory setting.
n Manual address setting
Setting
example
0 ~ 15
10
n Automatic address setting
Set this switch to 0 at factory setting.
- (07-03) -
Arbitrary numbers can be
REF AD
REF AD
x10
x1
SET3
SET5
See the setting method 1-6
Arbitrary numbers can be
REF AD
x10
x1
.
See the setting method 1-4-1
See the setting method 1-4-2
See the setting method 1-4-3
See the setting method 1-4-4
See the setting method 1-5-2
Arbitrary numbers can be
IU AD
x10
x1
.
See the setting method 1-4-1
See the setting method 1-4-2
See the setting method 1-4-3
See the setting method 1-4-4
See the setting method 1-5-2
RC AD
REMARKS
set in range of 00-99
DIP SW SET3-1
DIP SW SET3-2
DIP SW SET3-3
DIP SW SET3-4
(Master unit only)
DIP SW SET5-1
DIP SW SET5-2
DIP SW SET5-4
set in range of 00-99
set in range of 00-63
3-wire type R.C. can be
set in range of 0-15
2-wire type only