Fujitsu AIRSTAGE AJ 072LELBH Series Installation Manual

Fujitsu AIRSTAGE AJ 072LELBH Series Installation Manual

Outdoor unit
Hide thumbs Also See for AIRSTAGE AJ 072LELBH Series:

Advertisement

Quick Links

AJ*072LELBH
AJ*090LELBH
AJ*108LELBH
AJ*126LELBH
AJ*144LELBH
AJ*162LELBH
INSTALLATION MANUAL
For authorized service personnel only.
INSTALLATIONSANLEITUNG
Nur für autorisiertes Fachpersonal.
MANUEL D'INSTALLATION
Pour le personnel de service agrée uniquement.
MANUAL DE INSTALACIÓN
Únicamente para personal de servicio autorizado.
MANUALE D'INSTALLAZIONE
A uso esclusivo del personale tecnico autorizzato.
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό.
MANUAL DE INSTALAÇÃO
Somente para o pessoal do serviço técnico autorizado.
РУКОВОДСТВО ПО УСТАНОВКЕ
Только для авторизованного обслуживающего персонала.
KURULUM KILAVUZU
Yalnızca yetkili servis personeli için.
PART No. 9380545347
OUTDOOR UNIT
AUSSENGERÄT
UNITÉ EXTÉRIEURE
UNIDAD EXTERIOR
UNITÀ ESTERNA
ΕΞΩΤΕΡΙΚΉ ΜΟΝΆΔΑ
UNIDADE EXTERIOR
ВНЕШНИЙ МОДУЛЬ
DIŞ ÜNİTE
[Original instructions]

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu AIRSTAGE AJ 072LELBH Series

  • Page 1 INSTALLATION MANUAL OUTDOOR UNIT For authorized service personnel only. INSTALLATIONSANLEITUNG AUSSENGERÄT Nur für autorisiertes Fachpersonal. MANUEL D'INSTALLATION UNITÉ EXTÉRIEURE Pour le personnel de service agrée uniquement. MANUAL DE INSTALACIÓN UNIDAD EXTERIOR Únicamente para personal de servicio autorizado. AJ*072LELBH AJ*090LELBH MANUALE D'INSTALLAZIONE AJ*108LELBH UNITÀ...
  • Page 2: Table Of Contents

    INSTALLATION MANUAL 1. SAFETY PRECAUTIONS VRF system outdoor unit • Be sure to read this Installation manual thoroughly before installation. PART No. 9380545347 • The warnings and precautions indicated in this Installation manual contain important information pertaining to your safety. Be sure to observe them. Contents •...
  • Page 3: About This Product

    This mark indicates procedures which, if improperly per- 2. ABOUT THIS PRODUCT CAUTION formed, might possibly result in personal harm to the user, or damage to property. 2.1. Precautions for using R410A refrigerant This unit must be installed by qualified personnel with a capacity certificate for handling refrigerant fluids.
  • Page 4: Combinations

    2.4. Combinations 3.2. Drain processing The number of indoor units that can be connected are as follows: CAUTION Connectable total Outdoor unit cooling Maximum connect- Perform drain work in accordance with this Manual, and ensure that the drain water is Model indoor unit capacity properly drained.
  • Page 5: Transporting The Unit

    3.3.1 Single outdoor unit installation 3.3.3 Outdoor units installation in multi row When the upward area is open Unit: mm * The following settings are not recommended in case of cooling by a low outside tem- perature. Unit: mm (1) Obstacles at rear only (2) Obstacles at rear and sides only (1) Single parallel unit arrangement (2) Multiple parallel unit arrangement...
  • Page 6: Installing The Unit

    3.5. Installing the unit 4. SYSTEM CONFIGURATION • Please install the outdoor unit without slant. (within 0.3 degrees) For detailed information, refer to the Design and Technical Manual. • Install 4 anchor bolts at the locations indicated with arrows in the figure. 4.1.
  • Page 7: Protection Of Pipes

    Table. B (Diameter of piping used between outdoor unit and first separation 5. PIPE INSTALLATION tube or header) For the following installation conditions, it is necessary to increase the piping size. 5.1. Brazing • Condition 1: Total indoor unit capacity ratio ˃ 110% •...
  • Page 8: Opening The Knockout Hole

    5.4.2 Removing the pinch pipe 5.3. Opening the knockout hole WARNING CAUTION Remove the pinch pipe only when the internal gas is completely drained as shown on the below instructions. Be careful not to deform or scratch the panel while opening the knockout holes. If gas still remains inside, the piping may crack if you melt the brazing filler metal of the To protect the piping insulation after opening a knockout hole, remove any burrs from junction area with a burner.
  • Page 9: Electrical Wiring

    6. ELECTRICAL WIRING 6.2. Knockout hole CAUTION 6.1. The precautions of electrical wiring Be careful not to deform or scratch the panel while opening the knockout holes. WARNING After opening the knockout holes, remove burr on the edges, and attach the one-touch bush (accessory), grommet or conduit etc.
  • Page 10: Transmission Line

    6.4.3 Enabling/Disabling automatic address setting 6.4. Transmission line You can enable/disable automatic address setting for the indoor unit and the signal ampli- fier. CAUTION To enable automatic address setting for the indoor unit, connect the indoor unit to outdoor Caution when wiring cable: units under the same refrigerant system.
  • Page 11 6.5.2 Wiring procedure How to connect wiring to the terminal Caution when wiring cable • Remove the service panel. And connect the cable to the terminal in accordance with the terminal name plate. (1) Use ring terminals with insulating sleeves as shown in the figure to connect to the terminal block.
  • Page 12: External Input And External Output

    Operation behavior 6.6. External input and external output Each input terminal works as follows. 6.6.1 Terminal position Connector Input signal Status Base heater Normal operation Output 1 (CN136: Black) Input 1 (CN115: Black) CN131 (Yellow) Outdoor unit PC board Low noise mode operation EXT.
  • Page 13: Field Setting

    7. FIELD SETTING 7.3. Rotary switch setting The rotary switch (REF AD) sets the refrigerant circuit address of the outdoor unit. Config- CAUTION ure the settings only on the master unit of a refrigerant system. Discharge the static electricity from your body before setting up the DIP switches. If multiple refrigerant systems are connected, set the rotary switch (REF AD) as shown in the table below.
  • Page 14 (1) Turn on the power of the outdoor unit and enter standby mode. Level 1 (stop)  • When system is abnormal • When system is normal Level 2 Check the settings as there is an error in the POWER/MODE lamp lights up. (ER- (operated at 40% capacity) settings for outdoor unit address ROR lamp is off.)
  • Page 15: Address Setting For Signal Amplifi Ers

    7.6.2 Procedures to enable automatic address setting on indoor 7.5. Address setting for signal amplifi ers units 7.5.1 Address setting for signal amplifi ers Check that the rotary switch IU AD on the indoor unit PC board is set to “00”.If it is not set to “00”, it means the address of that device is not set.
  • Page 16: Pipe Installation Ii

    Evacuation procedure 8. PIPE INSTALLATION II (1) Remove the blank caps of the gas pipe and liquid pipe and check that the valves are closed. Fig. A: Connection diagram Fig. B (2) Remove the charging port cap. (3) Connect a vacuum pump and a pressure gauge to a charging hose and connect it to Service hose Pressure regu- Pressure...
  • Page 17: Installing Insulation

    (1) Calculation of additional amount for pipe length 9. TEST RUN Total length of ø 12.70 Total length of ø 9.52 mm liquid pipe mm liquid pipe a × 0.114 a × 0.058 9.1. Indoor unit connection check (kg/m) (kg/m) Normal operation will not be possible without performing the Indoor unit connection check.
  • Page 18: Pre-Check For Test Run

    9.1.3 Error displays Test operation setting method Use the “MODE/EXIT”, “SELECT”, and “ENTER” buttons on the indoor unit PC board to • When error occurs, “Err” and “Number of errors occurred” are alternately displayed on configure settings according to the procedures below. the 7-segment display every 1 second.
  • Page 19: Led Status

    Outdoor unit inverter PCB power short interruption component/ error Manufacturer Switch error Outdoor unit rush current limiting resister temp. rise FUJITSU GENERAL LIMITED (19) Manufacturer error (protective operation) Address: 3-3-17, Suenaga, Takatsu-ku, Kawasaki Outdoor unit transmission PCB parallel communica- 213-8502, Japan tion error 1 Outdoor unit discharge temp.

This manual is also suitable for:

Airstage aj 090lelbh seriesAirstage aj 108lelbh seriesAirstage aj 126lelbh seriesAirstage aj 144lelbh seriesAirstage aj 162lelbh seriesAirstage j-iv l ajy 162lelbh ... Show all

Table of Contents