Fujitsu AIRSTAGE J-III L AJ 072LELAH Series Design & Technical Manual page 654

Hide thumbs Also See for AIRSTAGE J-III L AJ 072LELAH Series:
Table of Contents

Advertisement

z Type : Outdoor
Object
Code
Function
name
(II)
Outdoor unit error status
30
BI
Forced OFF status
31
Forced OFF setting
BO
30
Outdoor unit priority
30
operation status *2
Outdoor unit error code
31
MI
Capacity Save Status
32
Outdoor low noise
33
operation setting *3
Outdoor low noise
30
operation setting *4
MO
Capacity Save Setting
32
*2) Priority operation status is for Heat Pump type VRF
In other types of systems, this status is not necessary.
*3) Refer to the "Outdoor unit low noise operation value table" for the texts used with the "Outdoor low noise operation
status"
*4) Outdoor unit firmware may need to be updated for this function to work.
Contact your local sales company for detail.
z Type : Gateway
Object
Code
name
(II)
-
Device information
Device
00
LON
Network Adaptor error status
®
01
Gateway error status
BI
02
ES Status
02
ES Setting
BO
00
LON
®
Network Adaptor unit error code
01
Gateway error code
02
ECA *1 status
MI
01
ECA *1 setting
MO
00-99 Notification class
Notification
00
Calendar "Holiday-1"
01
Calendar "Holiday-2"
CAL
02-31 Calendar "Special day-1" - "Special
day-30"
Schedule 00-99 Schedule timer
*1) ECA: Electricity Charge Apportionment.
 To protect the compressor of the outdoor unit, carefully read and understand the following cautions that may affect the
operation of the compressor before executing the setting.
• When regularly making the following settings to the same outdoor unit by using schedule function etc., leave the
following interval.
<Corresponding function>
·Reset outdoor unit forced off mode
Inactive
Active
Text-1
Text-2
Normal
Fault
Reset
Set
Reset
Set
Cool
Heat
Neutral
Refer to FGL original error code
Not Set
100%
Level-1
Level-1
Stop
Quiet
Not Set
100%
Function
Inactive
Text-1
Normal
Normal
Not Used
Not Used
Invalid
More than 6 minutes must elapse
More than 3 minutes must elapse
- (05 - 186) -
Unit
Text-3
Text-4
Text-5
None
90%
80%
70%
Level-2
Level-2
Ability
Quiet
Ability
90%
80%
70%
Unit
Active
Text-2
Text-3
Abnormal
Abnormal
Energy
Saving
Energy
Saving
Refer to FGL original error code
Refer to FGL original error code
Include
Invalid
Indoor
(Stop)
Unit Only
Exclude
Include
Indoor
Stop
Indoor
And RB
Unit Only
Unit
· Set outdoor unit forced off mode
Text-6
Text-7
Text-8
60%
50%
40%
Level-3
Level-3
Quiet
Ability
60%
50%
40%
Text-4
Text-5
Text-6
Exclude
Include
Include
Indoor
Indoor
RB Unit
And RB
And RB
Only
Unit
Unit
Include
Include
Indoor
RB Unit
And RB
Only
Unit