Usage Guide:
To configure Unknown Frames Storm Control Rate of QoS for specific interface
Example:
To configure Unknown Frames Storm Control Rate (999 fps) of QoS for
GigabitEthernet X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # qos storm unicast 999 fps
qos tag-remark
Command:
qos tag-remark pcp <Pcp : 0-7> dei <Dei : 0-1>
qos
Quality of Service
tag-remark
pcp
Specify default PCP
<Pcp : 0-7>
Specific PCP
dei
Specify default DEI
<Dei : 0-1>
Specific DEI
Default:
0
Usage Guide:
To enable Tag-remark default mode of QoS for specific interface
Example:
To enable Tag-remark default mode (PCP:1 , DEI:1) of QoS for GigabitEthernet
X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # qos tag-remark pcp 1 dei 1
qos tag-remark mapped
Command:
qos tag-remark mapped
qos
Quality of Service
tag-remark
mapped
Used mapped values (cos,dpl -> pcp,dei)
Default:
Classified
Usage Guide:
To enable Tag-remark mapped mode of QoS for specific interface