Chapter 4: Commands for CLI configuration
clock summer-time
Command:
clock summer-time <WORD> date <Monthstart: 1-12>
<Daystart: 1-31> <Yearstart: 1-12> <Timestart: hh:mm >
<Monthend: 1-12> <Dayend: 1-31> <Yearend: 1-12>
<Timeend: hh:mm > <Offset minutes: 1-1440 >
Default:
N/A
Usage Guide:
To set daylight saving.
Example:
To set daylight saving (Started time: Feb, 3. 2013 8:8AM, End time: Dec, 31. 2013
8:8AM, Offset time: 60 minutes).
Switch# configure terminal
Switch (config)# clock summer-time 1 date 2 3 2013 8:8 12 31
2013 8:8 60
clock timezone
Command:
clock timezone <WORD> <timezone: -23-23>
<WORD>
name of time zone
Default:
0
Usage Guide:
To set timezone.
Example:
To set timezone (GMT -15) with profile 1.
Switch# configure terminal
Switch (config)# clock timezone 1 -15
default access-list rate-limiter
Command:
default access-list rate-limiter <RateLimiterId : 1-16>
<RateLimiterId : 1-16>
Default:
0
Usage Guide:
To default the Rate limiter.
Example:
To default the Rate limiter ID 1.
40
Rate limiter ID