Chapter 4: Commands for CLI configuration
vlan
This MEP is a VLAN domain MEP.
flow
The flow instance that the MEP is related to.
<flow >
The flow instance number when not in the port domain.
vid
In case the MEP is a port Up-MEP or a EVC customer MIP the VID must be
given.
<Vid : vlan_id>
Default:
None
Usage Guide:
To configure Up-MEP of MEP.
Example:
To configure Up-MEP of MEP 2 as below table
Switch# configure terminal
Switch (config)# mep 2 up domain port vid 1 flow 1 level 2
interface GigabitEthernet 1/1
mep <Instance> vid
Command:
mep <Instance> vid <vid>
mep
Maintenance Entity Point
<Instance> The MEP instance number.
vid
The MEP VID
<Vid : vlan_id> The MEP VID value
Default:
0
Usage Guide:
To set VID of MEP.
Example:
To set VID (8) of MEP 1.
Switch# configure terminal
Switch (config)# mep 1 vid 8
mep <Instance> voe
Command:
mep <Instance> voe
mep
Maintenance Entity Point
<Instance>
The MEP instance number.
voe
MEP is VOE based
174
The port Domain MEP VID. This is required for a Port Up-MEP.