Interlogix NS4702-24P-4X Command Manual page 62

Managed switch
Hide thumbs Also See for NS4702-24P-4X:
Table of Contents

Advertisement

Chapter 4: Commands for CLI configuration
To configure Port-control mode for 802.1X
Example:
To configure Port-Based 802.1X(Auto) mode for GigabitEthernet X/X.
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # dot1x port-control auto
dot1x radius-qos
Command:
dot1x radius-qos
dot1x
IEEE Standard for port-based Network Access Control
radius-qos
Default:
Disable
Usage Guide:
To enable RADIUS-assigned QoS for 802.1X
Example:
To enable RADIUS-assigned QoS for GigabitEthernet X/X.
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # dot1x radius-qos
dot1x radius-vlan
Command:
dot1x radius-vlan
dot1x
IEEE Standard for port-based Network Access Control
radius-vlan
Default:
Disable
Usage Guide:
To enable RADIUS-assigned VLAN for 802.1X
Example:
To enable RADIUS-assigned VLAN for GigabitEthernet X/X.
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # dot1x radius-vlan
dot1x re-authenticate
Command:
dot1x re-authenticate
dot1x
IEEE Standard for port-based Network Access Control
re-authenticate
60
Enables/disables per-port state of RADIUS-assigned QoS.
Enables/disables per-port state of RADIUS-assigned VLAN.
Refresh (restart) 802.1X authentication process.
NS4702-24P-4X Managed Switch Command Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NS4702-24P-4X and is the answer not in the manual?

Questions and answers

Table of Contents