Interlogix NS4702-24P-4X Command Manual page 219

Managed switch
Hide thumbs Also See for NS4702-24P-4X:
Table of Contents

Advertisement

Usage Guide:
To enable the BPDU Guard of CIST Aggregated Port
Example:
To enable the BPDU Guard of CIST Aggregated Port
Switch# configure terminal
Switch (config)# snmp-server host IFS
Switch (config-snmps-host)# spanning-tree bpdu-guard
spanning-tree edge
Command:
spanning-tree edge
spanning-tree
edge
Edge port
Default:
Disabled
Usage Guide:
To enable the Admin Edge of CIST Aggregated Port
Example:
To enable the Admin Edge of CIST Aggregated Port
Switch# configure terminal
Switch (config)# snmp-server host IFS
Switch (config-snmps-host)# spanning-tree edge
spanning-tree link-type
Command:
spanning-tree link-type link-type { point-to-point | shared |
auto }
spanning-tree
link-type
Port link-type
auto
Auto detect
point-to-point
shared
Forced to Shared
Default:
Point to Point
Usage Guide:
To configure the Point to Point mode (Shared) of CIST Aggregated Port
Example:
To configure the Point to Point mode (Shared) of CIST Aggregated Port
Switch# configure terminal
Switch (config)# snmp-server host IFS
Switch (config-snmps-host)# spanning-tree link-type shared
NS4702-24P-4X Managed Switch Command Guide