Interlogix NS4702-24P-4X Command Manual page 85

Managed switch
Hide thumbs Also See for NS4702-24P-4X:
Table of Contents

Advertisement

poe priority
Command:
poe priority { low | high | critical }
poe
Power Over Ethernet.
priority
Interface priority.
critical
Set priority to critical.
high
Set priority to high.
low
Set priority to low.
Default:
2
Usage Guide:
To configure interface priority of PoE for specific interface.
Example:
To configure interface priority (low) of PoE for GigabitEthernet X/X.
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # poe priority low
poe time-range
Command:
poe time-range { profile1 | profile2 | profile3 | profile4 }
poe
Power Over Ethernet.
time-range
To bind a PoE time-range to the corresponding port.
profile1
The profile name of the PoE time-range to be bound to the port.
profile2
The profile name of the PoE time-range to be bound to the port.
profile3
The profile name of the PoE time-range to be bound to the port.
profile4
The profile name of the PoE time-range to be bound to the port.
Default:
Profile 1
Usage Guide:
To configure time-range profile of PoE for specific interface.
Example:
To configure time-range profile (Profile 3) of PoE for GigabitEthernet X/X.
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # poe time-range profile3
port-security
Command:
port-security
port-security
Default:
Disabled
Usage Guide:
NS4702-24P-4X Managed Switch Command Guide
Enable/disable port security per interface.
Chapter 4: Commands for CLI configuration