Base zero position is aligned so that the
output flange is offset 180 degrees from the
cable at the back of the robot base.
Wrist 2:
Wrist 2 zero position is aligned similar to
Base joint, with tool flange parallel with wrist
1 output flange.
10. Select Calibration tab and press Zero current joint position to calibrate the joint.
UR3
5. Service and Replacement of Parts
Shoulder, Elbow and Wrist 1 zero output
flange vertically aligned (assuming Base is
horizontal).
Make sure that base of robot is horizontal, use
spirit level to align joints.
Wrist 3:
Wrist 3 zero position is aligned so tool
connector is pointing upward.
Mount two bolts in tool holes and use spirit
level to align joint.
44
Service Manual