Universal Robots UR3 Service Manual page 149

Hide thumbs Also See for UR3:
Table of Contents

Advertisement

7. Troubleshooting
C261A0
Critical error
to
C261A3
C261A4
Temperature is too
to
high (degrees
C261A15
Celsius)
C262A
Communication
C262A0
Critical error
to
C262A18
C263A
Motor Encoder
C263A0
Critical error on
to
Motor Encoder
C263A31
C264A
Task Manager
C264A0
Critical error on Task
to
Manager
C264A11
C265A
Joint Encoder
C265A0
Critical error on
to
Joint encoder
C265A30
Service Manual
A critical error occurred in
the temperature sensor
Ambient temperature is too
high or low. Temperature
sensor read a temperature
outside the allowed range.
A critical error occurred in
the communication
framework
A critical error occurred in
the Motor Encoder.
A critical error occurred in
the task manager. Overload
of the task manager.
A critical error occurred in
the Joint Encoder
143
a) Do a Complete rebooting
sequence
b) Contact your local
Universal Robots service
provider for assistance.
a) Check robot's environment
and make sure the robot is
operating within
recommended limits.
b) Do a Complete rebooting
sequence
a) Check communications
external and internal
b) Do a Complete rebooting
sequence
c) Check for ESD noise
d) Update software
e) Contact your local
Universal Robots service
provider for assistance.
a) Do a Complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance.
a) Do a Complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance.
a) Do a Complete rebooting
sequence
b) Update robot's software
c) Check for ESD noise
d) Update software
e) Contact your local
Universal Robots service
provider for assistance.
UR3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents