7. Troubleshooting
C25A
Motor Encoder index
missing
C26A
Motor Encoder index
drift detected
C27A
Calibration data is
invalid or does not
exist.
C29A
Online Calibration
data checksum
failed
C30A
Master received
data from too many
joints
C31A
Caught wrong
message (not from
master)
C32A
Flash write verify
failed
C33A
Calibration flash
checksum failed
C34A
Program flash
checksum failed
C34A0
Program flash
checksum failed
during bootloading
C34A1
Program flash
checksum failed at
runtime
C35A
Joint ID is undefined
Service Manual
Joint's encoder system
mechanical problem
Joint's encoder system
mechanical problem
Calibration needed
Serial communication
problem with joint
99
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
joint
c) Contact your local UR
provider
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
joint
c) Contact your local UR
provider
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
joint
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
joint
Check black 2-wire
connectors and wires on
joints
Update Firmware
Update Firmware
Update Firmware
UR3