Universal Robots UR3 Service Manual page 172

Hide thumbs Also See for UR3:
Table of Contents

Advertisement

C283A51
Tool moved with a
speed which
exceeds the speed
limit
C283A52
Elbow moved with a
speed of which
exceeds the speed
limit
C283A53
Maximum Tool
Center Point Speed
in Reduced Mode is
invalid
C283A54
Maximum Elbow
Speed in Reduced
Mode is invalid
C283A55
Maximum Joint
Speed of a specified
joint in Reduced
Mode is invalid
C283A56
Maximum
Momentum in
Reduced Mode is
invalid
C283A57
Maximum stopping
time in Reduced
Mode is invalid
C283A58
Maximum stopping
distance in Reduced
Mode is invalid
C283A59
Reduced Mode
Output is not active
UR3
Failed to activate the
Reduced Mode Output. The
output is active when
voltage is low
166
7. Troubleshooting
a) Ensure the mounted
payload, TCP and CoG
matches your configuration.
b) Slow down movements
c) Check safety setting
d) Contact your local
Universal Robots service
provider for assistance.
a) Ensure the mounted
payload, TCP and CoG
matches your configuration.
b) Slow down movements
c) Check safety setting
d) Contact your local
Universal Robots service
provider for assistance.
Ensure the Reduced Mode
Limit is less than or equal to
the Normal Mode limit.
Ensure the Reduced Mode
limit is less than or equal to
the Normal Mode Limit.
Ensure the Reduced Mode
Limit is less than or equal to
the Normal Mode Limit.
Ensure the Reduced Mode
Limit is less than or equal to
the Normal Mode Limit.
Ensure the Reduced Mode
Limit is less than or equal to
the Normal Mode Limit.
Ensure the Reduced Mode
Limit is less than or equal to
the Normal Mode Limit.
Make sure output is not short
circuited to a power supply
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents