Universal Robots UR3 Service Manual page 182

Hide thumbs Also See for UR3:
Table of Contents

Advertisement

C297A
Joint validation
C297A0
Critical error
C297A1
Joint validation
C297A2
Joint validation
C297A3
Joint validation
C297A4
Joint validation
C297A5
Joint validation
C297A6
Joint validation
C297A7
Joint validation
C297A8
Joint validation
C297A9
Joint validation
C297A10
Joint validation
C297A11
The Robot arm does
not match the
Control Box
UR3
Validation during power up.
A critical error occurred
during Joint validation
Received Node ID from an
unexpected device
Received Node ID an
unexpected node
Joint processors disagree
on Joint Size
Joints disagree with
configuration on Joint Size
Found Joint disabled in
configuration
Joint processors disagree
on Joint ID.
Node ID differs from the
stored ID.
Invalid robot configuration
Joint IDs need updating
Timeout while waiting for
Node IDs
One or more joints do not
match stored Robot
Configuration
176
7. Troubleshooting
a) Do a Complete rebooting
sequence
b) Check that SD card and
robot type match.
c) Update software    
d) Contact your local
Universal Robots service
provider for assistance.
a) Do a Complete rebooting
sequence
b) Check that SD card and
robot type match.
c) Update software    
d) Contact your local
Universal Robots service
provider for assistance.
a) Do a Complete rebooting
sequence
b) Check that SD card and
robot type match.
c) Update software    
d) Contact your local
Universal Robots service
provider for assistance.
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents