Universal Robots UR3 Service Manual page 192

Hide thumbs Also See for UR3:
Table of Contents

Advertisement

C309A
Critical error
C309A0
Keep-Alive System
C309A1
Keep-Alive System
C309A2
Keep-Alive System
C309A3
Keep-Alive System
C309A4
Keep-Alive System
C309A5
Keep-Alive System
C309A6
Keep-Alive System
C309A7
Keep-Alive System
C309A8
Keep-Alive System
C309A9
Keep-Alive System
UR3
A critical error occurred in
the Keep-Alive System
Critical error
Keep-Alive System
message with wrong
sequence received from
SCB-uPA.
Timeout reached while
waiting for a Keep-Alive
System message from SCB-
uPA.
Go-to-Fault command
received a Keep-Alive
System message from SCB-
uPA.
A Keep-Alive System
message with wrong
sequence received from
SCB-uPB.
Timeout reached while
waiting for Keep-Alive
System message from SCB-
uPB.
Go-to-Fault command
received in Keep-Alive
System message from SCB-
uPB.
Keep-Alive System
message received from an
unauthorized source
uPA handler received an
invalid value
uPB handler received an
invalid value
186
7. Troubleshooting
a) Conduct a complete
rebooting sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents