Universal Robots UR3 Service Manual page 148

Hide thumbs Also See for UR3:
Table of Contents

Advertisement

C220A1
Kinematic
Calibration
C220A2
Kinematic
Calibration
C220A3
Kinematic
Calibration
C220A4
Kinematic
Calibration
C257A
Unknown message
C258A
Invalid Payload
C259A
Filesystem related
issue
C259A0
Critical error
to
C259A81
C260A
Brake Release
C260A0
Critical error
C260A1
Brake Release
to
C260A21
C261A
Temperature Sensor
UR3
Actual version on the robot
arm is not supported
Kinematic Calibration file
was replaced with file from
the arm
Kinematic Calibration
uploaded to the arm
Kinematic Calibration
reuploaded to the arm
A critical error occurred in
the filesystem
Brake release not
responding properly
A critical error occurred
during Brake Release
Motor moved only
142
7. Troubleshooting
Update Software
Update Software
Update Software
Update Software
Please insert a valid payload
a) Do a Complete rebooting
sequence
b) Update robot Software
c) Reimage SD card
d) Contact your local
Universal Robots service
provider for assistance.
a) Check the brake release
system
b) Do a Complete rebooting
sequence 
c) Contact your local
Universal Robots service
provider for assistance.
a) Do a Complete rebooting
sequence
b) Ensure the mounted
payload, TCP and CoG
matches your configuration.
c) Update robot software
d) For further assistance,
contact your local Universal
Robots service provider.
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents