Universal Robots UR3 Service Manual page 106

Hide thumbs Also See for UR3:
Table of Contents

Advertisement

C36A
Illegal bootloader
command
C37A
Inbuffer parse error
C38A
Online RAM test
failed
C38A1
Data-bus test failed
C38A2
Address-bus stuck-
high test failed
C38A3
Address-bus stuck-
low test failed
C38A4
Address-bus shorted
test failed
C38A5
Memory-cell test
failed
C39A
Logic and Temporal
Monitoring Fault
C39A1
Max current
deviation failure
C39A2
Max joint-encoder
speed exceeded
C39A3
Max motor-encoder
speed exceeded
C39A4
Illegal state change
in joint detected
C39A5
A timing issue
occurred during
startup.
C39A6
5V regulator voltage
too low
C39A7
5V regulator voltage
too high
C39A100
Watchpoint fault:
ADC task timeout
UR3
Serial communication
problem with joint
Too fast state change in
joint detected
100
7. Troubleshooting
Check black 2-wire
connectors and wires on
joints
Check the log file for what
item is reporting this error.
Replace the reported item
a) Do a Complete rebooting
sequence.
b) If this happens more than
two times in a row, replace
joint
Same as C39A1
Same as C39A1
 Same as C39A1
Same as C39A1
Same as C39A1
Same as C39A1
 Same as C39A1